31,519 research outputs found
Robust Cardiac Motion Estimation using Ultrafast Ultrasound Data: A Low-Rank-Topology-Preserving Approach
Cardiac motion estimation is an important diagnostic tool to detect heart
diseases and it has been explored with modalities such as MRI and conventional
ultrasound (US) sequences. US cardiac motion estimation still presents
challenges because of the complex motion patterns and the presence of noise. In
this work, we propose a novel approach to estimate the cardiac motion using
ultrafast ultrasound data. -- Our solution is based on a variational
formulation characterized by the L2-regularized class. The displacement is
represented by a lattice of b-splines and we ensure robustness by applying a
maximum likelihood type estimator. While this is an important part of our
solution, the main highlight of this paper is to combine a low-rank data
representation with topology preservation. Low-rank data representation
(achieved by finding the k-dominant singular values of a Casorati Matrix
arranged from the data sequence) speeds up the global solution and achieves
noise reduction. On the other hand, topology preservation (achieved by
monitoring the Jacobian determinant) allows to radically rule out distortions
while carefully controlling the size of allowed expansions and contractions.
Our variational approach is carried out on a realistic dataset as well as on a
simulated one. We demonstrate how our proposed variational solution deals with
complex deformations through careful numerical experiments. While maintaining
the accuracy of the solution, the low-rank preprocessing is shown to speed up
the convergence of the variational problem. Beyond cardiac motion estimation,
our approach is promising for the analysis of other organs that experience
motion.Comment: 15 pages, 10 figures, Physics in Medicine and Biology, 201
Blind deconvolution of medical ultrasound images: parametric inverse filtering approach
©2007 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or distribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.DOI: 10.1109/TIP.2007.910179The problem of reconstruction of ultrasound images by means of blind deconvolution has long been recognized as one of the central problems in medical ultrasound imaging. In this paper, this problem is addressed via proposing a blind deconvolution method which is innovative in several ways. In particular, the method is based on parametric inverse filtering, whose parameters are optimized using two-stage processing. At the first stage, some partial information on the point spread function is recovered. Subsequently, this information is used to explicitly constrain the spectral shape of the inverse filter. From this perspective, the proposed methodology can be viewed as a ldquohybridizationrdquo of two standard strategies in blind deconvolution, which are based on either concurrent or successive estimation of the point spread function and the image of interest. Moreover, evidence is provided that the ldquohybridrdquo approach can outperform the standard ones in a number of important practical cases. Additionally, the present study introduces a different approach to parameterizing the inverse filter. Specifically, we propose to model the inverse transfer function as a member of a principal shift-invariant subspace. It is shown that such a parameterization results in considerably more stable reconstructions as compared to standard parameterization methods. Finally, it is shown how the inverse filters designed in this way can be used to deconvolve the images in a nonblind manner so as to further improve their quality. The usefulness and practicability of all the introduced innovations are proven in a series of both in silico and in vivo experiments. Finally, it is shown that the proposed deconvolution algorithms are capable of improving the resolution of ultrasound images by factors of 2.24 or 6.52 (as judged by the autocorrelation criterion) depending on the type of regularization method used
Sparsity driven ultrasound imaging
An image formation framework for ultrasound imaging from synthetic transducer arrays based on sparsity-driven regularization functionals using single-frequency Fourier domain data is proposed. The framework involves the use of a physics-based forward model of the ultrasound observation process, the formulation of image formation as the solution of an associated optimization problem, and the solution of that problem through efficient numerical algorithms. The sparsity-driven, model-based approach estimates a complex-valued reflectivity field and preserves physical features in the scene while suppressing spurious artifacts. It also provides robust reconstructions in the case of sparse and reduced observation apertures. The effectiveness of the proposed imaging strategy is demonstrated using experimental data
A Framework for Directional and Higher-Order Reconstruction in Photoacoustic Tomography
Photoacoustic tomography is a hybrid imaging technique that combines high
optical tissue contrast with high ultrasound resolution. Direct reconstruction
methods such as filtered backprojection, time reversal and least squares suffer
from curved line artefacts and blurring, especially in case of limited angles
or strong noise. In recent years, there has been great interest in regularised
iterative methods. These methods employ prior knowledge on the image to provide
higher quality reconstructions. However, easy comparisons between regularisers
and their properties are limited, since many tomography implementations heavily
rely on the specific regulariser chosen. To overcome this bottleneck, we
present a modular reconstruction framework for photoacoustic tomography. It
enables easy comparisons between regularisers with different properties, e.g.
nonlinear, higher-order or directional. We solve the underlying minimisation
problem with an efficient first-order primal-dual algorithm. Convergence rates
are optimised by choosing an operator dependent preconditioning strategy. Our
reconstruction methods are tested on challenging 2D synthetic and experimental
data sets. They outperform direct reconstruction approaches for strong noise
levels and limited angle measurements, offering immediate benefits in terms of
acquisition time and quality. This work provides a basic platform for the
investigation of future advanced regularisation methods in photoacoustic
tomography.Comment: submitted to "Physics in Medicine and Biology". Changes from v1 to
v2: regularisation with directional wavelet has been added; new experimental
tests have been include
Sparsity-driven sparse-aperture ultrasound imaging
We propose an image formation algorithm for ultrasound imaging based on sparsity-driven regularization functionals. We consider data collected by synthetic transducer arrays, with the primary motivating application being nondestructive evaluation. Our framework involves the use of a physical optics-based forward model of the observation process; the formulation of an optimization problem for image formation; and the solution of that problem through efficient numerical algorithms. Our sparsity-driven, model-based approach achieves the preservation of physical features while suppressing spurious artifacts. It also provides robust reconstructions in the case of sparse observation apertures. We demonstrate the effectiveness of our imaging strategy on real ultrasound data
Gaussian mixture model based probabilistic modeling of images for medical image segmentation
In this paper, we propose a novel image segmentation algorithm that is based on the probability distributions of the object and background. It uses the variational level sets formulation with a novel region based term in addition to the edge-based term giving a complementary functional, that can potentially result in a robust segmentation of the images. The main theme of the method is that in most of the medical imaging scenarios, the objects are characterized by some typical characteristics such a color, texture, etc. Consequently, an image can be modeled as a Gaussian mixture of distributions corresponding to the object and background. During the procedure of curve evolution, a novel term is incorporated in the segmentation framework which is based on the maximization of the distance between the GMM corresponding to the object and background. The maximization of this distance using differential calculus potentially leads to the desired segmentation results. The proposed method has been used for segmenting images from three distinct imaging modalities i.e. magnetic resonance imaging (MRI), dermoscopy and chromoendoscopy. Experiments show the effectiveness of the proposed method giving better qualitative and quantitative results when compared with the current state-of-the-art. INDEX TERMS Gaussian Mixture Model, Level Sets, Active Contours, Biomedical Engineerin
- …