911 research outputs found

    Soft Robot-Assisted Minimally Invasive Surgery and Interventions: Advances and Outlook

    Get PDF
    Since the emergence of soft robotics around two decades ago, research interest in the field has escalated at a pace. It is fuelled by the industry's appreciation of the wide range of soft materials available that can be used to create highly dexterous robots with adaptability characteristics far beyond that which can be achieved with rigid component devices. The ability, inherent in soft robots, to compliantly adapt to the environment, has significantly sparked interest from the surgical robotics community. This article provides an in-depth overview of recent progress and outlines the remaining challenges in the development of soft robotics for minimally invasive surgery

    Towards tactile sensing active capsule endoscopy

    Get PDF
    Examination of the gastrointestinal(GI) tract has traditionally been performed using tethered endoscopy tools with limited reach and more recently with passive untethered capsule endoscopy with limited capability. Inspection of small intestines is only possible using the latter capsule endoscopy with on board camera system. Limited to visual means it cannot detect features beneath the lumen wall if they have not affected the lumen structure or colour. This work presents an improved capsule endoscopy system with locomotion for active exploration of the small intestines and tactile sensing to detect deformation of the capsule outer surface when it follows the intestinal wall. In laboratory conditions this system is capable of identifying sub-lumen features such as submucosal tumours.Through an extensive literary review the current state of GI tract inspection in particular using remote operated miniature robotics, was investigated, concluding no solution currently exists that utilises tactile sensing with a capsule endoscopy. In order to achieve such a platform, further investigation was made in to tactile sensing technologies, methods of locomotion through the gut, and methods to support an increased power requirement for additional electronics and actuation. A set of detailed criteria were compiled for a soft formed sensor and flexible bodied locomotion system. The sensing system is built on the biomimetic tactile sensing device, Tactip, \cite{Chorley2008, Chorley2010, Winstone2012, Winstone2013} which has been redesigned to fit the form of a capsule endoscopy. These modifications have required a 360o360^{o} cylindrical sensing surface with 360o360^{o} panoramic optical system. Multi-material 3D printing has been used to build an almost complete sensor assembly with a combination of hard and soft materials, presenting a soft compliant tactile sensing system that mimics the tactile sensing methods of the human finger. The cylindrical Tactip has been validated using artificial submucosal tumours in laboratory conditions. The first experiment has explored the new form factor and measured the device's ability to detect surface deformation when travelling through a pipe like structure with varying lump obstructions. Sensor data was analysed and used to reconstruct the test environment as a 3D rendered structure. A second tactile sensing experiment has explored the use of classifier algorithms to successfully discriminate between three tumour characteristics; shape, size and material hardness. Locomotion of the capsule endoscopy has explored further bio-inspiration from earthworm's peristaltic locomotion, which share operating environment similarities. A soft bodied peristaltic worm robot has been developed that uses a tuned planetary gearbox mechanism to displace tendons that contract each worm segment. Methods have been identified to optimise the gearbox parameter to a pipe like structure of a given diameter. The locomotion system has been tested within a laboratory constructed pipe environment, showing that using only one actuator, three independent worm segments can be controlled. This configuration achieves comparable locomotion capabilities to that of an identical robot with an actuator dedicated to each individual worm segment. This system can be miniaturised more easily due to reduced parts and number of actuators, and so is more suitable for capsule endoscopy. Finally, these two developments have been integrated to demonstrate successful simultaneous locomotion and sensing to detect an artificial submucosal tumour embedded within the test environment. The addition of both tactile sensing and locomotion have created a need for additional power beyond what is available from current battery technology. Early stage work has reviewed wireless power transfer (WPT) as a potential solution to this problem. Methods for optimisation and miniaturisation to implement WPT on a capsule endoscopy have been identified with a laboratory built system that validates the methods found. Future work would see this combined with a miniaturised development of the robot presented. This thesis has developed a novel method for sub-lumen examination. With further efforts to miniaturise the robot it could provide a comfortable and non-invasive procedure to GI tract inspection reducing the need for surgical procedures and accessibility for earlier stage of examination. Furthermore, these developments have applicability in other domains such as veterinary medicine, industrial pipe inspection and exploration of hazardous environments

    From passive tool holders to microsurgeons: safer, smaller, smarter surgical robots

    No full text

    A disposable continuum endoscope using piston-driven parallel bellow actuator

    Get PDF
    This paper presents a novel low cost disposable continuum endoscope based on a piston-driven parallel bellow actuator design. The parallel bellow actuator achieves motion by being pressurized via displacement-controlled pistons. The displacements are generated by rack-and-pinion mechanisms using inexpensive stepper motors. The design concept provides a potential alternative solution to upper gastrointestinal (UGI) diagnosis. The modularity and the use of inexpensive components allow for low fabrication costs and disposability. The use of robotic assistance could facilitate the development of an easier interface for the gastroenterologists, avoiding the nonintuitive manipulation mapping of the traditional UGI endoscopes. We adapt existing kinematic solutions of multi-backbone continuum robots to model continuum parallel bellow actuators. An actuation compensation strategy is presented and validated to address the pneumatic compressibility through the transmission lines. The design concept was prototyped and tested with a custom control platform. The experimental validation shows that the actuation compensation was demonstrated to significantly improve orientation control of the endoscope end-effector. This paper shows the feasibility of the proposed design and lays the foundation toward clinical scenarios

    Robotic technology and endoluminal surgery in digestive surgery

    Get PDF
    BACKGROUND. Colorectal cancer (CRC) is the third most common cancer in males and second in females, and the fourth most common cause of cancer death worldwide. The implementation of screening programs has allowed to the identification of an increasing number of early-stage neoplastic lesions. Presently, superficial colorectal neoplasms (including precancerous lesions and early cancer) can be resected in the colon by Endoscopic Mucosal Resection (EMR) and Endoscopic Submucosal Dissection (ESD), while in the rectum by Transanal Endoscopic Microsurgery (TEM). They are the preferred choices inside of the minimally invasive panorama regarding the CRC treatment. TEM technique offers more advantages than EMR and ESD, but it can’t overcome the recto-sigmoid junction. Many authors, research institutes and biomedical industries have proposed different solutions for microsurgery dissection of early lesions in the colon, but all these proposals have in common the development of platforms expressly designed for this use, with significant purchasing and management costs. The aim of our research project is to develop a robotic platform that allows to treat lesions throughout the colon limiting the costs of management and purchasing. This new robotic platform, developed in collaboration with Scuola Superiore Sant’Anna in Pisa, is called RED (Robot for Endoscopic Dissection). At the tip of a standard endoscope a hood (RED) is placed. RED is equipped by two extractable teleoperated robotic arms (i.e., diathermic hook and gripper); their motion is provided by onboard miniaturized commercial motors and a dedicated external platform. The endoscopist holds the endoscope near the lesion, while the operator drives the robotic arms through a remote control. MATERIALS AND METHODS. Several preliminary studies have been conducted in the following order. A first test was conducted for identification of force value for lifting and pulling maneuvers using a modified TEM instrument. A CAD study was conducted to determine the maximum size that the hood must have in order to overcome the critical angle represented by the splenic flexure. Several tests were conducted to determine the degrees of freedom of each robotic arm, starting with the CAD drawing to make subsequently the mock-ups of each configuration. Finally, a 3D mock-up was produced that was assembled on an endoscope to perform the in vitro test to evaluate the workspace and field of view using a pelvic trainer for TEM. RESULTS. The first test shown that the minimum force that the gripper will have to develop with the push-pull is 1.5N. The CAD study shown that the maximum dimensions the hood must have to overcome splenic flexure are: maximum diameter 28mm, maximum length 57mm. After several configurations was been tested, the final prototype features are: gripper arm with pitch sliding and open/close of the tip and diathermic hook arm with pitch, roll and sliding. There will be 6 such distributed motors: 3 external motors for the gripper arm that will operate through cables contained in a sheath adherent to colonscope and 3 embedded motors for diathermic hook arm (one integrated on the hood for the sliding degree of motion and the other two inside of the arm). The in-vitro test has been carried out to evaluate the workspace and they proved that the operating field vision is not obstructed by the hood and the working range is sufficiently wide to perform a dissection. CONCLUSION. Tests conducted up to this point have allowed us to identify the overall layout of the RED: dimensions, degrees of freedom, number and distribution of motors needed for the operation of robotic arms; moreover, it is proved that the device, once assembled, maintained the visual and operational field characteristics necessary to perform an accurate dissection. The next step will be to realize a RED steel final prototype and in-vivo tests will be carry out to replicate an endoscopic dissection into the colon
    • …
    corecore