2,724 research outputs found

    Impact Assessment of Hypothesized Cyberattacks on Interconnected Bulk Power Systems

    Full text link
    The first-ever Ukraine cyberattack on power grid has proven its devastation by hacking into their critical cyber assets. With administrative privileges accessing substation networks/local control centers, one intelligent way of coordinated cyberattacks is to execute a series of disruptive switching executions on multiple substations using compromised supervisory control and data acquisition (SCADA) systems. These actions can cause significant impacts to an interconnected power grid. Unlike the previous power blackouts, such high-impact initiating events can aggravate operating conditions, initiating instability that may lead to system-wide cascading failure. A systemic evaluation of "nightmare" scenarios is highly desirable for asset owners to manage and prioritize the maintenance and investment in protecting their cyberinfrastructure. This survey paper is a conceptual expansion of real-time monitoring, anomaly detection, impact analyses, and mitigation (RAIM) framework that emphasizes on the resulting impacts, both on steady-state and dynamic aspects of power system stability. Hypothetically, we associate the combinatorial analyses of steady state on substations/components outages and dynamics of the sequential switching orders as part of the permutation. The expanded framework includes (1) critical/noncritical combination verification, (2) cascade confirmation, and (3) combination re-evaluation. This paper ends with a discussion of the open issues for metrics and future design pertaining the impact quantification of cyber-related contingencies

    Scenarios for the development of smart grids in the UK: literature review

    Get PDF
    Smart grids are expected to play a central role in any transition to a low-carbon energy future, and much research is currently underway on practically every area of smart grids. However, it is evident that even basic aspects such as theoretical and operational definitions, are yet to be agreed upon and be clearly defined. Some aspects (efficient management of supply, including intermittent supply, two-way communication between the producer and user of electricity, use of IT technology to respond to and manage demand, and ensuring safe and secure electricity distribution) are more commonly accepted than others (such as smart meters) in defining what comprises a smart grid. It is clear that smart grid developments enjoy political and financial support both at UK and EU levels, and from the majority of related industries. The reasons for this vary and include the hope that smart grids will facilitate the achievement of carbon reduction targets, create new employment opportunities, and reduce costs relevant to energy generation (fewer power stations) and distribution (fewer losses and better stability). However, smart grid development depends on additional factors, beyond the energy industry. These relate to issues of public acceptability of relevant technologies and associated risks (e.g. data safety, privacy, cyber security), pricing, competition, and regulation; implying the involvement of a wide range of players such as the industry, regulators and consumers. The above constitute a complex set of variables and actors, and interactions between them. In order to best explore ways of possible deployment of smart grids, the use of scenarios is most adequate, as they can incorporate several parameters and variables into a coherent storyline. Scenarios have been previously used in the context of smart grids, but have traditionally focused on factors such as economic growth or policy evolution. Important additional socio-technical aspects of smart grids emerge from the literature review in this report and therefore need to be incorporated in our scenarios. These can be grouped into four (interlinked) main categories: supply side aspects, demand side aspects, policy and regulation, and technical aspects.

    Advanced Testing Chain Supporting the Validation of Smart Grid Systems and Technologies

    Full text link
    New testing and development procedures and methods are needed to address topics like power system stability, operation and control in the context of grid integration of rapidly developing smart grid technologies. In this context, individual testing of units and components has to be reconsidered and appropriate testing procedures and methods need to be described and implemented. This paper addresses these needs by proposing a holistic and enhanced testing methodology that integrates simulation/software- and hardware-based testing infrastructure. This approach presents the advantage of a testing environment, which is very close to f i eld testing, includes the grid dynamic behavior feedback and is risks-free for the power system, for the equipment under test and for the personnel executing the tests. Furthermore, this paper gives an overview of successful implementation of the proposed testing approach within different testing infrastructure available at the premises of different research institutes in Europe.Comment: 2018 IEEE Workshop on Complexity in Engineering (COMPENG

    False data injection attack detection in smart grid

    Get PDF
    Smart grid is a distributed and autonomous energy delivery infrastructure that constantly monitors the operational state of its overall network using smart techniques and state estimation. State estimation is a powerful technique that is used to determine the overall operational state of the system based on a limited set of measurements collected through metering systems. Cyber-attacks pose serious risks to a smart grid state estimation that can cause disruptions and power outages resulting in huge economical losses and are therefore a big concern to a reliable national grid operation. False data injection attacks (FDIAs), engineered on the basis of the knowledge of the network configuration, are difficult to detect using the traditional data detection mechanisms. These detection schemes have been found vulnerable and failed to detect these FDIAs. FDIAs specifically target the state data and can manipulate the state measurements in such a way that these false measurements appear real to the main control systems. This research work explores the possibility of FDIA detection using state estimation in a distributed and partitioned smart grid. In order to detect FDIAs we use measurements for residual-based testing which creates an objective function; and the probability of erroneous data is determined from this residual test. In this test, a preset threshold is determined based on the prior history of the state data. FDIA cases are simulated within a smart grid considering that the Chi-square detection state estimator fails in identifying such attacks. We compute the objective function using the standard weighted least problem and then test the objective function against the value in the Chi-square table. The gain matrix and the Jacobian matrix are computed. The state variables are computed in the form of a voltage magnitude. The state variables are computed after the inception of an attack to assess these state magnitude results. Different sizes of partitioning are used to improve the overall sensitivity of the Chi-square results. Our additional estimator is based on a Kalman estimation that consists of the state prediction and state correction steps. In the first step, it obtains the state and matrix covariance prediction, and in the second step, it calculates the Kalman gain and the state and matrix covariance update steps. The set of points is created for the state vector x at a time instant t. The initial vector and covariance matrix are based on a priori knowledge of the historical estimates. A set of sigma points is estimated by the state update function. Sigma points refer to the minimal set of sampling points that are selected and transformed using nonlinear function, and the new mean and the covariance are formed out of these transformed points. The idea behind this is that it is easier to compute a Gaussian distribution than an arbitrary nonlinear function. The filter gain, the mean and the covariance are used to estimate the next state. Our simulation results show that the combination of Kalman estimation and distributed state estimation improves the overall stability index and vulnerability assessment score of the smart grid. We built a stability index table for a smart grid based on the state estimates value after the inception of an FDIA. The vulnerability assessment score of the smart grid is based on common vulnerability scoring system (CVSS) and state estimates under the influence of an FDIA. The simulations are conducted in the MATPOWER program and different electrical bus systems such as IEEE 14, 30, 39, 118 and 300 are tested. All the contributions have been published in reputable journals and conferences.Doctor of Philosoph
    • …
    corecore