8 research outputs found
Towards Single-Chip Nano-Systems
Important scientific discoveries are being propelled by the advent of nano-scale sensors that capture weak signals from their environment and pass them to complex instrumentation interface circuits for signal detection and processing. The highlight of this research is to investigate fabrication technologies to integrate such precision equipment with nano-sensors on a single complementary metal oxide semiconductor (CMOS) chip. In this context, several demonstration vehicles are proposed. First, an integration technology suitable for a fully integrated flexible microelectrode array has been proposed. A microelectrode array containing a single temperature sensor has been characterized and the versatility under dry/wet, and relaxed/strained conditions has been verified. On-chip instrumentation amplifier has been utilized to improve the temperature sensitivity of the device. While the flexibility of the array has been confirmed by laminating it on a fixed single cell, future experiments are necessary to confirm application of this device for live cell and tissue measurements. The proposed array can potentially attach itself to the pulsating surface of a single living cell or a network of cells to detect their vital signs
Development and modelling of a versatile active micro-electrode array for high density in-vivo and in-vitro neural signal investigation
The electrophysiological observation of neurological cells has allowed much knowledge to be gathered regarding how living organisms are believed to acquire and process sensation. Although much has been learned about neurons in isolation, there is much more to be discovered in how these neurons communicate within large networks. The challenges of measuring neurological networks at the scale, density and chronic level of non invasiveness required to observe neurological processing and decision making are manifold, however methods have been suggested that have allowed small scale networks to be observed using arrays of micro-fabricated electrodes. These arrays transduce ionic perturbations local to the cell membrane in the extracellular fluid into small electrical signals within the metal that may be measured.
A device was designed for optimal electrical matching to the electrode interface and maximal signal preservation of the received extracellular neural signals. Design parameters were developed from electrophysiological computer simulations and experimentally obtained empirical models of the electrode-electrolyte interface. From this information, a novel interface based signal filtering method was developed that enabled high density amplifier interface circuitry to be realised.
A novel prototype monolithic active electrode was developed using CMOS microfabrication technology. The device uses the top metallization of a selected process to form the electrode substrate and compact amplification circuitry fabricated directly beneath the electrode to amplify and separate the neural signal from the baseline offsets and noise of the electrode interface. The signal is then buffered for high speed sampling and switched signal routing. Prototype 16 and 256 active electrode array with custom support circuitry is presented at the layout stage for a 20 μm diameter 100 μm pitch electrode array. Each device consumes 26.4 μW of power and contributes 4.509 μV (rms) of noise to the received signal over a controlled bandwidth of 10 Hz - 5 kHz.
The research has provided a fundamental insight into the challenges of high density neural network observation, both in the passive and the active manner. The thesis concludes that power consumption is the fundamental limiting factor of high density integrated MEA circuitry; low power dissipation being crucial for the existence of the surface adhered cells under measurement. With transistor sizing, noise and signal slewing each being inversely proportional to the dc supply current and the large power requirements of desirable ancillary circuitry such as analogue-to-digital converters, a situation of compromise is approached that must be carefully considered for specific application design
Recommended from our members
Conformable transistors for bioelectronics
The diversity of network disruptions that occur in patients with neuropsychiatric disorders creates a strong demand for personalized medicine. Such approaches often take the form of implantable bioelectronic devices that are capable of monitoring pathophysiological activity for identifying biomarkers to allow for local and responsive delivery of intervention. They are also required to transmit this data outside of the body for evaluation of the treatment’s efficacy.
However, the ability to perform these demanding electronic functions in the complex physiological environment with minimum disruption to the biological tissue remains a big challenge. An optimal fully implantable bioelectronic device would require each component from the front-end to the data transmission to be conformable and biocompatible. For this reason, organic material-based conformable electronics are ideal candidates for components of bioelectronic circuits due to their inherent flexibility, and soft nature.
In this work, first an organic mixed-conducting particulate composite material (MCP) able to form functional electronic components and non-invasively acquire high–spatiotemporal resolution electrophysiological signals by directly interfacing human skin is presented. Secondly, we introduce organic electrochemical internal ion-gated transistors (IGTs) as a high-density, high-amplification sensing component as well as a low leakage, high-speed processing unit.
Finally, a novel wireless, battery-free strategy for electrophysiological signal acquisition, processing, and transmission that employs IGTs and an ionic communication circuit (IC) is introduced. We show that the wirelessly-powered IGTs are able to acquire and modulate neurophysiological data in-vivo and transmit them transdermally, eliminating the need for any hard Si-based electronics in the implant
Optoelectronics – Devices and Applications
Optoelectronics - Devices and Applications is the second part of an edited anthology on the multifaced areas of optoelectronics by a selected group of authors including promising novices to experts in the field. Photonics and optoelectronics are making an impact multiple times as the semiconductor revolution made on the quality of our life. In telecommunication, entertainment devices, computational techniques, clean energy harvesting, medical instrumentation, materials and device characterization and scores of other areas of R&D the science of optics and electronics get coupled by fine technology advances to make incredibly large strides. The technology of light has advanced to a stage where disciplines sans boundaries are finding it indispensable. New design concepts are fast emerging and being tested and applications developed in an unimaginable pace and speed. The wide spectrum of topics related to optoelectronics and photonics presented here is sure to make this collection of essays extremely useful to students and other stake holders in the field such as researchers and device designers
Micro-optics for Opto-genetic Neuro-stimulation with Micro-LED Arrays
The breakthrough discovery of a nanoscale optically gated ion channel protein, Channelrhodopsin 2 (ChR2), in combination with a genetically expressed optically activated ion pump, Halorhodopsin, allowed the direct stimulation and inhibition of individual action potentials with light alone. This thesis describes the development of optics and micro-optics which when used with micro-led array sources, collects and projects light efficiently and uniformly onto such opto-genetically modified specimens. When used with enhanced light gated ion channels and pumps these systems allow us to further our understanding of both brain and visual systems.
Micro-LED arrays permit spatio-temporal control of neuron stimulation on sub-millisecond timescales. However, micro-led arrays are disadvantaged by the broad-angular spread of their light emission and their low spatial fill factor. We present the design of macro and micro-optics systems for use with a micro-LED arrays consisting of a matrix of 25μm diameter micro-LEDs with 150 or 80μm centre-to-centre spacing. On one system, the micro-LED array is imaged onto off-the-shelf micro-optics using macro-optics and in the other system; micro-LED array and custom micro-optics are optimised and integrated together. The two systems are designed to improve the fill-factor from 2% to more than 78% by capturing a larger fraction of the LED emission and directing it correctly to the sample plane. This approach allows low fill factor arrays to be used effectively, which in turn has benefits in terms of thermal management and electrical drive from CMOS backplane electronics. These systems were implemented as an independent set that could be connected to a variety of different microscopes available for Patch-clamp and Multi-electrode measurements. As well, the feasibility of an eye prosthesis was tested using virtual reality optics and a fake eye to stimulate ganglion cells and by doing in-vivo stimulation of the genetically modified retina of a mouse.Open Acces
Recommended from our members
A hybrid piezoelectric and electrostatic energy harvester for scavenging arterial pulsations
Implantable and wearable biomedical devices suffer from a limited lifespan of on-board batteries which results in a requirement to change the battery or the device itself causing additional physical discomfort. In order to overcome this, various energy harvesters have been developed. The human body possesses several types of energy available for scavenging through appropriately designed energy harvesting devices, while cardiovascular system in particular represents a constant reliable source of mechanical energy from vibration. Most conventional energy harvesters exploit only a single phenomenon, such piezo- or triboelectricity, thus producing reduced power density. As an improvement, hybridisation of energy harvesters intends to negate this drawback by simultaneously scavenging energy by multiple harvesters.
In the present work, the reverse electrowetting on dielectric (REWOD) phenomenon is combined with the piezoelectric effect in a proof-of-concept hybrid harvester for scavenging biomechanical energy from arterial or other type pulsations. A mathematical model of the harvester was developed, and a computational investigation using CFD, and fluid-structure interaction simulations were carried out using the COMSOL Multiphysics software. The effect of the materials of piezoelectric film and geometrical features of the harvester on parameters such as the displacement, the frequency of pulsations and the energy produced were studied. An experimental setup that could imitate the displacements caused from arterial pulsations was designed and the produced electrical energy characteristics were analysed. A comparison between experimental and computational data was carried out and demonstrated a good agreement. Dependencies between geometrical parameters and electrical output were obtained, recommendation on piezoelectric materials and design solutions were provided
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
We present the science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems, targeting an evolution in technology, that might lead to impacts and benefits reaching into most areas of society. This roadmap was developed within the framework of the European Graphene Flagship and outlines the main targets and research areas as best understood at the start of this ambitious project. We provide an overview of the key aspects of graphene and related materials (GRMs), ranging from fundamental research challenges to a variety of applications in a large number of sectors, highlighting the steps necessary to take GRMs from a state of raw potential to a point where they might revolutionize multiple industries. We also define an extensive list of acronyms in an effort to standardize the nomenclature in this emerging field.Peer ReviewedPostprint (published version