13 research outputs found
Low Profile Stretch Sensor for Soft Wearable Robotics
This paper presents a low profile stretch sensor for integration into soft structures, robots and wearables. The sensor mechanism uses a single piece of highly flexible and light weight optical fibre and is based on the notion that bending an optical fibre modulates the intensity of the light transmitted through the fibre, a technique often referred as macrobending light loss. In this arrangement, the optical fibre originates from sensor’s electronic unit, passes through a stretchable encasing structure in a macrobend pattern, and then loop back to the same unit resulting in a simplified electrical and optical design; the closed optical loop allows for no electronics at one end of the sensor making it safe for human robotics applications, and no optical interference with the external environment eliminating the need for complex conditioning circuitries. Of particular interest of the soft robotics community, the ability of this custom macrobend stretch sensor to flexibly adapt its configuration allows preserving the inherent softness and compliance of the robot which it is installed on. Our experimental results indicate that the optical fibre’s bending radius is the dominant design parameter for sufficiently complex patterns, a finding that can facilitate generalisation of the sensing methods across different scales. The measurement performance of the mechanism and its impact on the stiffness of the encasing structure is benchmarked against a custom calibration and testing system
Macrobend optical sensing for pose measurement in soft robot arms
This paper introduces a pose-sensing system for soft robot arms integrating a set of macrobend stretch sensors. The macrobend sensory design in this study consists of optical fibres and is based on the notion that bending an optical fibre modulates the intensity of the light transmitted through the fibre. This sensing method is capable of measuring bending, elongation and compression in soft continuum robots and is also applicable to wearable sensing technologies, e.g. pose sensing in the wrist joint of a human hand. In our arrangement, applied to a cylindrical soft robot arm, the optical fibres for macrobend sensing originate from the base, extend to the tip of the arm, and then loop back to the base. The connectors that link the fibres to the necessary opto-electronics are all placed at the base of the arm, resulting in a simplified overall design. The ability of this custom macrobend stretch sensor to flexibly adapt its configuration allows preserving the inherent softness and compliance of the robot which it is installed on. The macrobend sensing system is immune to electrical noise and magnetic fields, is safe (because no electricity is needed at the sensing site), and is suitable for modular implementation in multi-link soft continuum robotic arms. The measurable light outputs of the proposed stretch sensor vary due to bend-induced light attenuation (macrobend loss), which is a function of the fibre bend radius as well as the number of repeated turns. The experimental study conducted as part of this research revealed that the chosen bend radius has a far greater impact on the measured light intensity values than the number of turns (if greater than five). Taking into account that the bend radius is the only significantly influencing design parameter, the macrobend stretch sensors were developed to create a practical solution to the pose sensing in soft continuum robot arms. Henceforward, the proposed sensing design was benchmarked against an electromagnetic tracking system (NDI Aurora) for validation
Image-based Optical Miniaturized Three-Axis Force Sensor for Cardiac Catheterization
In order to determine the cause of and to treat an abnormal heart rhythm, electrophysiological studies and ablation procedures of the heart, sensorized catheters are required. During catheterization, force sensors at the tip of the catheter are essential to provide quantitative information on the interacting force between the catheter tip and the heart tissue. In this study, we are proposing a small sized, robust, and low-cost three-axis force sensor for the catheter tip. The miniaturized force sensor uses fiber-optic technology (small sized multi-cores optical fiber and a CCD camera) based on image processing to read out the forces by measuring light intensity which are modulated as a function of the applied force. In addition, image processing techniques and a Kalman filter are used to reduce the noise of the light intensity signals. In this paper, we explain the design and fabrication of our three-axis force sensor and our approach for reducing noise levels by applying a Kalman filter model, and finally discuss the calibration procedure. Moreover, we provide an assessment of the performance of the proposed sensor
Recommended from our members
Optoelectronic-based pose sensing for a hand rehabilitation exoskeleton continuous structure
10.13039/501100001809-National Natural Science Foundation of China (Grant Number: 51975451); 10.13039/501100001809-Royal Society of Edinburgh (RSE)—National Natural Science Foundation of China (NSFC) Joint Project (Grant Number: 51911530243); 10.13039/501100007128-Natural Science Foundation of Shaanxi Province of China (Grant Number: 2019JQ-332); 10.13039/501100012226-Fundamental Research Funds for the Central Universities (Grant Number: xzy012019012)
Multifunctional arm for telerobotic wind turbine blade repair
Within the Multi-Platform Inspection, Maintenance and Repair in Extreme Environments (MIMRee) project, a lightweight and multifunctional robotic repair arm is created for wind turbine blades. The design features a toolbox at the base of the arm housing multiple end-effector tools and an autonomous end-effector tool-changer. The arm communicates commands and data via internet with a bespoke user interface enabling human-in-the-loop operation and overriding of autonomous repair actions. This paper outlines our approach in design, development, testing and control of the robotic repair system. The functionalities of the arm include cleaning, sanding, and filler material deposition and forming, each using a bespoke end-effector tool closely replicating the relevant manual repair process. The experimental results confirm the effectiveness of our approach indicating a maximum end-effector position error of 3 mm, a maximum tool switching time of 8 seconds, and a maximum arm’s weight of 1.8 kg. This presents around 84% weight reduction compared with existing technologies used for the same purpose. Our standalone design enables modular integration into a wide range of mobile platform types used in industrial operations
Multi-Axis force/torque sensor based on Simply-Supported beam and optoelectronics
© 2016 by the authors; licensee MDPI, Basel, Switzerland. This paper presents a multi-axis force/torque sensor based on simply-supported beam and optoelectronic technology. The sensor’s main advantages are: (1) Low power consumption, (2) low-level noise in comparison with conventional methods of force sensing (e.g., using strain gauges), (3) the ability to be embedded into different mechanical structures, (4) miniaturisation, (5) simple manufacture and customisation to fit a wide-range of robot systems, and (6) low-cost fabrication and assembly of sensor structure. For these reasons, the proposed multi-axis force/torque sensor can be used in a wide range of application areas including medical robotics, manufacturing, and areas involving human-robot interaction. This paper shows the application of our concept of a force/torque sensor to flexible continuum manipulators: A cylindrical MIS (Minimally Invasive Surgery) robot, and includes its design, fabrication, and evaluation tests.The research leading to these results has received funding from the European Commission’s Seventh Framework Programme; project STIFF-FLOP (Grant No. 287728), and has received funding from the
Wellcome Trust IEH Award (Grant No. 102431)
A continuum robotic platform for endoscopic non-contact laser surgery: design, control, and preclinical evaluation
The application of laser technologies in surgical interventions has been accepted in the clinical
domain due to their atraumatic properties. In addition to manual application of fibre-guided
lasers with tissue contact, non-contact transoral laser microsurgery (TLM) of laryngeal tumours
has been prevailed in ENT surgery. However, TLM requires many years of surgical training
for tumour resection in order to preserve the function of adjacent organs and thus preserve the
patient’s quality of life. The positioning of the microscopic laser applicator outside the patient
can also impede a direct line-of-sight to the target area due to anatomical variability and limit
the working space. Further clinical challenges include positioning the laser focus on the tissue
surface, imaging, planning and performing laser ablation, and motion of the target area during
surgery. This dissertation aims to address the limitations of TLM through robotic approaches and
intraoperative assistance. Although a trend towards minimally invasive surgery is apparent, no
highly integrated platform for endoscopic delivery of focused laser radiation is available to date.
Likewise, there are no known devices that incorporate scene information from endoscopic imaging
into ablation planning and execution. For focusing of the laser beam close to the target tissue, this
work first presents miniaturised focusing optics that can be integrated into endoscopic systems.
Experimental trials characterise the optical properties and the ablation performance. A robotic
platform is realised for manipulation of the focusing optics. This is based on a variable-length
continuum manipulator. The latter enables movements of the endoscopic end effector in five
degrees of freedom with a mechatronic actuation unit. The kinematic modelling and control of the
robot are integrated into a modular framework that is evaluated experimentally. The manipulation
of focused laser radiation also requires precise adjustment of the focal position on the tissue. For
this purpose, visual, haptic and visual-haptic assistance functions are presented. These support
the operator during teleoperation to set an optimal working distance. Advantages of visual-haptic
assistance are demonstrated in a user study. The system performance and usability of the overall
robotic system are assessed in an additional user study. Analogous to a clinical scenario, the
subjects follow predefined target patterns with a laser spot. The mean positioning accuracy of the
spot is 0.5 mm. Finally, methods of image-guided robot control are introduced to automate laser
ablation. Experiments confirm a positive effect of proposed automation concepts on non-contact
laser surgery.Die Anwendung von Lasertechnologien in chirurgischen Interventionen hat sich aufgrund der atraumatischen Eigenschaften in der Klinik etabliert. Neben manueller Applikation von fasergeführten
Lasern mit Gewebekontakt hat sich die kontaktfreie transorale Lasermikrochirurgie (TLM) von
Tumoren des Larynx in der HNO-Chirurgie durchgesetzt. Die TLM erfordert zur Tumorresektion
jedoch ein langjähriges chirurgisches Training, um die Funktion der angrenzenden Organe zu
sichern und damit die Lebensqualität der Patienten zu erhalten. Die Positionierung des mikroskopis chen Laserapplikators außerhalb des Patienten kann zudem die direkte Sicht auf das Zielgebiet
durch anatomische Variabilität erschweren und den Arbeitsraum einschränken. Weitere klinische
Herausforderungen betreffen die Positionierung des Laserfokus auf der Gewebeoberfläche, die
Bildgebung, die Planung und Ausführung der Laserablation sowie intraoperative Bewegungen
des Zielgebietes. Die vorliegende Dissertation zielt darauf ab, die Limitierungen der TLM durch
robotische Ansätze und intraoperative Assistenz zu adressieren. Obwohl ein Trend zur minimal
invasiven Chirurgie besteht, sind bislang keine hochintegrierten Plattformen für die endoskopische
Applikation fokussierter Laserstrahlung verfügbar. Ebenfalls sind keine Systeme bekannt, die
Szeneninformationen aus der endoskopischen Bildgebung in die Ablationsplanung und -ausführung
einbeziehen. Für eine situsnahe Fokussierung des Laserstrahls wird in dieser Arbeit zunächst
eine miniaturisierte Fokussieroptik zur Integration in endoskopische Systeme vorgestellt. Experimentelle Versuche charakterisieren die optischen Eigenschaften und das Ablationsverhalten. Zur
Manipulation der Fokussieroptik wird eine robotische Plattform realisiert. Diese basiert auf einem
längenveränderlichen Kontinuumsmanipulator. Letzterer ermöglicht in Kombination mit einer
mechatronischen Aktuierungseinheit Bewegungen des Endoskopkopfes in fünf Freiheitsgraden.
Die kinematische Modellierung und Regelung des Systems werden in ein modulares Framework
eingebunden und evaluiert. Die Manipulation fokussierter Laserstrahlung erfordert zudem eine
präzise Anpassung der Fokuslage auf das Gewebe. Dafür werden visuelle, haptische und visuell haptische Assistenzfunktionen eingeführt. Diese unterstützen den Anwender bei Teleoperation
zur Einstellung eines optimalen Arbeitsabstandes. In einer Anwenderstudie werden Vorteile der
visuell-haptischen Assistenz nachgewiesen. Die Systemperformanz und Gebrauchstauglichkeit
des robotischen Gesamtsystems werden in einer weiteren Anwenderstudie untersucht. Analog zu
einem klinischen Einsatz verfolgen die Probanden mit einem Laserspot vorgegebene Sollpfade. Die
mittlere Positioniergenauigkeit des Spots beträgt dabei 0,5 mm. Zur Automatisierung der Ablation
werden abschließend Methoden der bildgestützten Regelung vorgestellt. Experimente bestätigen
einen positiven Effekt der Automationskonzepte für die kontaktfreie Laserchirurgie