2,064 research outputs found
An Open-Source 7-Axis, Robotic Platform to Enable Dexterous Procedures within CT Scanners
This paper describes the design, manufacture, and performance of a highly
dexterous, low-profile, 7 Degree-of-Freedom (DOF) robotic arm for CT-guided
percutaneous needle biopsy. Direct CT guidance allows physicians to localize
tumours quickly; however, needle insertion is still performed by hand. This
system is mounted to a fully active gantry superior to the patient's head and
teleoperated by a radiologist. Unlike other similar robots, this robot's fully
serial-link approach uses a unique combination of belt and cable drives for
high-transparency and minimal-backlash, allowing for an expansive working area
and numerous approach angles to targets all while maintaining a small in-bore
cross-section of less than . Simulations verified the system's
expansive collision free work-space and ability to hit targets across the
entire chest, as required for lung cancer biopsy. Targeting error is on average
on a teleoperated accuracy task, illustrating the system's sufficient
accuracy to perform biopsy procedures. The system is designed for lung biopsies
due to the large working volume that is required for reaching peripheral lung
lesions, though, with its large working volume and small in-bore
cross-sectional area, the robotic system is effectively a general-purpose
CT-compatible manipulation device for percutaneous procedures. Finally, with
the considerable development time undertaken in designing a precise and
flexible-use system and with the desire to reduce the burden of other
researchers in developing algorithms for image-guided surgery, this system
provides open-access, and to the best of our knowledge, is the first
open-hardware image-guided biopsy robot of its kind.Comment: 8 pages, 9 figures, final submission to IROS 201
Prevalence of haptic feedback in robot-mediated surgery : a systematic review of literature
© 2017 Springer-Verlag. This is a post-peer-review, pre-copyedit version of an article published in Journal of Robotic Surgery. The final authenticated version is available online at: https://doi.org/10.1007/s11701-017-0763-4With the successful uptake and inclusion of robotic systems in minimally invasive surgery and with the increasing application of robotic surgery (RS) in numerous surgical specialities worldwide, there is now a need to develop and enhance the technology further. One such improvement is the implementation and amalgamation of haptic feedback technology into RS which will permit the operating surgeon on the console to receive haptic information on the type of tissue being operated on. The main advantage of using this is to allow the operating surgeon to feel and control the amount of force applied to different tissues during surgery thus minimising the risk of tissue damage due to both the direct and indirect effects of excessive tissue force or tension being applied during RS. We performed a two-rater systematic review to identify the latest developments and potential avenues of improving technology in the application and implementation of haptic feedback technology to the operating surgeon on the console during RS. This review provides a summary of technological enhancements in RS, considering different stages of work, from proof of concept to cadaver tissue testing, surgery in animals, and finally real implementation in surgical practice. We identify that at the time of this review, while there is a unanimous agreement regarding need for haptic and tactile feedback, there are no solutions or products available that address this need. There is a scope and need for new developments in haptic augmentation for robot-mediated surgery with the aim of improving patient care and robotic surgical technology further.Peer reviewe
Medical image computing and computer-aided medical interventions applied to soft tissues. Work in progress in urology
Until recently, Computer-Aided Medical Interventions (CAMI) and Medical
Robotics have focused on rigid and non deformable anatomical structures.
Nowadays, special attention is paid to soft tissues, raising complex issues due
to their mobility and deformation. Mini-invasive digestive surgery was probably
one of the first fields where soft tissues were handled through the development
of simulators, tracking of anatomical structures and specific assistance
robots. However, other clinical domains, for instance urology, are concerned.
Indeed, laparoscopic surgery, new tumour destruction techniques (e.g. HIFU,
radiofrequency, or cryoablation), increasingly early detection of cancer, and
use of interventional and diagnostic imaging modalities, recently opened new
challenges to the urologist and scientists involved in CAMI. This resulted in
the last five years in a very significant increase of research and developments
of computer-aided urology systems. In this paper, we propose a description of
the main problems related to computer-aided diagnostic and therapy of soft
tissues and give a survey of the different types of assistance offered to the
urologist: robotization, image fusion, surgical navigation. Both research
projects and operational industrial systems are discussed
Planning and Real Time Control of a Minimally Invasive Robotic Surgery System
This paper introduces the planning and control software of a teleoperating robotic system for minimally invasive surgery. It addresses the problem of how to organize a complex system with 41 degrees of freedom including robot setup planning, force feedback control and nullspace handling with three robotic arms. The planning software is separated into sequentially executed planning and registration procedures. An optimal setup is first planned in virtual reality and then adapted to variations in the operating room. The real time control system is composed of hierarchical layers. The design is flexible and expandable without losing performance. Structure, functionality and implementation of planning and control are described. The robotic system provides the surgeon with an intuitive hand-eye-coordination and force feedback in teleoperation for both hands
- …