5,321 research outputs found
Characterization of the on-body path Loss at 2.45 GHz and energy efficient WBAN design for dairy cows
Wireless body area networks (WBANs) provide promising applications in the healthcare monitoring of dairy cows. The characterization of the path loss (PL) between on-body nodes constitutes an important step in the deployment of a WBAN. In this paper, the PL between nodes placed on the body of a dairy cow was determined at 2.45 GHz. Finite-difference time domain simulations with two half-wavelength dipoles placed 20 mm above a cow model were performed using a 3-D electromagnetic solver. Measurements were conducted on a live cow to validate the simulation results. Excellent agreement between measurements and simulations was achieved and the obtained PL values as a function of the transmitter-receiver separation were well fitted by a lognormal PL model with a PL exponent of 3.1 and a PL at reference distance ( 10 cm) of 44 dB. As an application, the packet error rate ( PER) and the energy efficiency of different WBAN topologies for dairy cows (i.e., single-hop, multihop, and cooperative networks) were investigated. The analysis results revealed that exploiting multihop and cooperative communication schemes decrease the PER and increase the optimal payload packet size. The analysis results revealed that exploiting multihop and cooperative communication schemes increase the optimal payload packet size and improve the energy efficiency by 30%
Wireless body sensor networks for health-monitoring applications
This is an author-created, un-copyedited version of an article accepted for publication in
Physiological Measurement. The publisher is
not responsible for any errors or omissions in this version of the manuscript or any version
derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/0967-3334/29/11/R01
On-body wearable repeater as a data link relay for in-body wireless implants
Wireless medical devices implanted at different locations in the human body have a wide application range. Yet, high-data-rate communication in the 2.4-GHz Industrial, Scientific, and Medical band suffers from high in-body attenuation loss. Link improvement cannot be obtained by simply increasing transmit power, as battery life is limited and in-body absorption has to remain low. To overcome these problems, a flexible on-body textile patch antenna, robustly matched directly to the human body, is designed and developed as part of a wearable repeater, enhancing communication with implanted wireless devices. This receive antenna, which can cope with different morphologies and patient movements, enables reliable high data rate and low-power communication links with an implant. A data link measurement is performed for the on-body repeater system placed on the human torso, relaying the signals to nearby medical equipment, without wired connection to the patient. The performance of the data link is experimentally assessed in different measurement scenarios. For a repeater system relying on simple analog amplification, which is low-cost, energy-efficient, and can be fully integrated into clothing, excellent results are obtained, with an average measured signal-to-noise ratio of 33 dB for tissue depths up to 85 mm
Implementing and Evaluating a Wireless Body Sensor System for Automated Physiological Data Acquisition at Home
Advances in embedded devices and wireless sensor networks have resulted in
new and inexpensive health care solutions. This paper describes the
implementation and the evaluation of a wireless body sensor system that
monitors human physiological data at home. Specifically, a waist-mounted
triaxial accelerometer unit is used to record human movements. Sampled data are
transmitted using an IEEE 802.15.4 wireless transceiver to a data logger unit.
The wearable sensor unit is light, small, and consumes low energy, which allows
for inexpensive and unobtrusive monitoring during normal daily activities at
home. The acceleration measurement tests show that it is possible to classify
different human motion through the acceleration reading. The 802.15.4 wireless
signal quality is also tested in typical home scenarios. Measurement results
show that even with interference from nearby IEEE 802.11 signals and microwave
ovens, the data delivery performance is satisfactory and can be improved by
selecting an appropriate channel. Moreover, we found that the wireless signal
can be attenuated by housing materials, home appliances, and even plants.
Therefore, the deployment of wireless body sensor systems at home needs to take
all these factors into consideration.Comment: 15 page
Wearable Communications in 5G: Challenges and Enabling Technologies
As wearable devices become more ingrained in our daily lives, traditional
communication networks primarily designed for human being-oriented applications
are facing tremendous challenges. The upcoming 5G wireless system aims to
support unprecedented high capacity, low latency, and massive connectivity. In
this article, we evaluate key challenges in wearable communications. A
cloud/edge communication architecture that integrates the cloud radio access
network, software defined network, device to device communications, and
cloud/edge technologies is presented. Computation offloading enabled by this
multi-layer communications architecture can offload computation-excessive and
latency-stringent applications to nearby devices through device to device
communications or to nearby edge nodes through cellular or other wireless
technologies. Critical issues faced by wearable communications such as short
battery life, limited computing capability, and stringent latency can be
greatly alleviated by this cloud/edge architecture. Together with the presented
architecture, current transmission and networking technologies, including
non-orthogonal multiple access, mobile edge computing, and energy harvesting,
can greatly enhance the performance of wearable communication in terms of
spectral efficiency, energy efficiency, latency, and connectivity.Comment: This work has been accepted by IEEE Vehicular Technology Magazin
- âŠ