36 research outputs found

    Millimeter-Scale and Energy-Efficient RF Wireless System

    Full text link
    This dissertation focuses on energy-efficient RF wireless system with millimeter-scale dimension, expanding the potential use cases of millimeter-scale computing devices. It is challenging to develop RF wireless system in such constrained space. First, millimeter-sized antennae are electrically-small, resulting in low antenna efficiency. Second, their energy source is very limited due to the small battery and/or energy harvester. Third, it is required to eliminate most or all off-chip devices to further reduce system dimension. In this dissertation, these challenges are explored and analyzed, and new methods are proposed to solve them. Three prototype RF systems were implemented for demonstration and verification. The first prototype is a 10 cubic-mm inductive-coupled radio system that can be implanted through a syringe, aimed at healthcare applications with constrained space. The second prototype is a 3x3x3 mm far-field 915MHz radio system with 20-meter NLOS range in indoor environment. The third prototype is a low-power BLE transmitter using 3.5x3.5 mm planar loop antenna, enabling millimeter-scale sensors to connect with ubiquitous IoT BLE-compliant devices. The work presented in this dissertation improves use cases of millimeter-scale computers by presenting new methods for improving energy efficiency of wireless radio system with extremely small dimensions. The impact is significant in the age of IoT when everything will be connected in daily life.PHDElectrical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttps://deepblue.lib.umich.edu/bitstream/2027.42/147686/1/yaoshi_1.pd

    A self-powered single-chip wireless sensor platform

    Get PDF
    Internet of things” require a large array of low-cost sensor nodes, wireless connectivity, low power operation and system intelligence. On the other hand, wireless biomedical implants demand additional specifications including small form factor, a choice of wireless operating frequencies within the window for minimum tissue loss and bio-compatibility This thesis describes a low power and low-cost internet of things system suitable for implant applications that is implemented in its entirety on a single standard CMOS chip with an area smaller than 0.5 mm2. The chip includes integrated sensors, ultra-low-power transceivers, and additional interface and digital control electronics while it does not require a battery or complex packaging schemes. It is powered through electromagnetic (EM) radiation using its on-chip miniature antenna that also assists with transmit and receive functions. The chip can operate at a short distance (a few centimeters) from an EM source that also serves as its wireless link. Design methodology, system simulation and optimization and early measurement results are presented

    Beyond Tissue replacement: The Emerging role of smart implants in healthcare

    Get PDF
    Smart implants are increasingly used to treat various diseases, track patient status, and restore tissue and organ function. These devices support internal organs, actively stimulate nerves, and monitor essential functions. With continuous monitoring or stimulation, patient observation quality and subsequent treatment can be improved. Additionally, using biodegradable and entirely excreted implant materials eliminates the need for surgical removal, providing a patient-friendly solution. In this review, we classify smart implants and discuss the latest prototypes, materials, and technologies employed in their creation. Our focus lies in exploring medical devices beyond replacing an organ or tissue and incorporating new functionality through sensors and electronic circuits. We also examine the advantages, opportunities, and challenges of creating implantable devices that preserve all critical functions. By presenting an in-depth overview of the current state-of-the-art smart implants, we shed light on persistent issues and limitations while discussing potential avenues for future advancements in materials used for these devices

    Low-Noise Energy-Efficient Sensor Interface Circuits

    Full text link
    Today, the Internet of Things (IoT) refers to a concept of connecting any devices on network where environmental data around us is collected by sensors and shared across platforms. The IoT devices often have small form factors and limited battery capacity; they call for low-power, low-noise sensor interface circuits to achieve high resolution and long battery life. This dissertation focuses on CMOS sensor interface circuit techniques for a MEMS capacitive pressure sensor, thermopile array, and capacitive microphone. Ambient pressure is measured in the form of capacitance. This work propose two capacitance-to-digital converters (CDC): a dual-slope CDC employs an energy efficient charge subtraction and dual comparator scheme; an incremental zoom-in CDC largely reduces oversampling ratio by using 9b zoom-in SAR, significantly improving conversion energy. An infrared gesture recognition system-on-chip is then proposed. A hand emits infrared radiation, and it forms an image on a thermopile array. The signal is amplified by a low-noise instrumentation chopper amplifier, filtered by a low-power 30Hz LPF to remove out-band noise including the chopper frequency and its harmonics, and digitized by an ADC. Finally, a motion history image based DSP analyzes the waveform to detect specific hand gestures. Lastly, a microphone preamplifier represents one key challenge in enabling voice interfaces, which are expected to play a dominant role in future IoT devices. A newly proposed switched-bias preamplifier uses switched-MOSFET to reduce 1/f noise inherently.PHDElectrical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttps://deepblue.lib.umich.edu/bitstream/2027.42/137061/1/chaseoh_1.pd

    Design, Fabrication, and Validation of a Highly Miniaturized Wirelessly Powered Neural Implant

    Get PDF
    We have recently witnessed an explosion in the number of neurons that can be recorded and/or stimulated simultaneously during neurophysiological experiments. Experiments have progressed from recording or stimulation with a single electrode to Micro-Electrode Array (MEA) such as the Utah Array. These MEAs can be instrumented with current drivers, neural amplifiers, digitizers and wireless communication links. The broad interest in these MEAs suggests that there is a need for large scale neural recording and stimulation. The ultimate goal is to coordinate the recordings and stimulation of potentially thousands of neurons from many brain areas. Unfortunately, current state-of-the-art MEAs are limited by their scalability and long-term stability because of their physical size and rigid configuration. Furthermore, some applications prioritize a distributed neural interface over one that offers high resolution. Examples of biomedical applications that necessitate an interface with neurons from many sites in the brain include: i) understanding and treating neurological disorders that affect distributed locations throughout the CNS; ii) revolutionizing our understanding of the brain by studying the correlations between neural networks from different regions of the brain and the mechanisms of cognitive functions; and iii) covering larger area in the sensorimotor cortex of amputees to more accurately control robotic prosthetic limbs or better evoke a sense of touch. One solution to make large scale, fully specifiable, electrical stimulation and recording possible, is to disconnect the electrodes from the base, so that they can be arbitrarily placed, using a syringe, freely in the nervous system. To overcome the challenges of system miniaturization, we propose the “microbead”, an ultra-small neural stimulating implant, that is currently implemented in a 130nm CMOS technology with the following characteristics: 200 μm × 200 μm × 80 μm size; optimized wireless powering, all micro-electronics on single chip; and integrated electrodes and coil. The stimulating microbead is validated in a sciatic nerve by generating leg movements. A recording microbead is also investigated with following characteristics: wireless powering using steerable phased coil array, miniaturized front-end, and backscattering telemetry. These microbeads could eventually replace the rigid arrays that are currently the state-of-the-art in electrophysiology set-ups

    Doctor of Philosophy

    Get PDF
    dissertationMagnetic fields are permeable to the biological tissues and can induce electric field in the conductive structures. Some medical devices take advantage of this ability to transfer energy from the source to the receiving site without direct contact. Prosthetic devices such as retinal implants use time-varying magnetic field to achieve wireless power transfer to the implanted magnetic coil. However, devices such as magnetic stimulators use the induction principle to create an electric field at the stimulation site. Efficiency of these devices is primarily dependent on the design of the magnetic coils. Therefore, in this work, we designed and validated efficient magnetic coils for wireless power transfer to implanted devices and magnetic stimulation of the peripheral nerves. Typical wireless power transfer (WPT) systems uses two-coil based design to achieve contactless power transfer to the implanted electronics. These systems achieve low power transfer efficiency (< 30%) and frequency bandwidth. Moreover, efficient wireless system requires high coupling and load variation tolerance during device operation. To design an electromagnetic safe WPT system, the power absorbed by the tissue and radiated field due to the proximal magnetic coils needs to be minimized. In this work, we proposed a multi-coil power transfer system which solves some of the current challenges. The proposed multi-coil WPT system achieves more than twice the power transfer efficiency, controllable voltage gain, wider frequency bandwidth, higher tolerance to coupling and load variations, lower absorbed power in the tissue and lower radiated field from the magnetic coil than a comparable two-coil system. In this work, we have developed analytic models of the multi-coil WPT system and validated the accuracy of the solutions using experiments. Magnetic coils play an important role in controlling the distribution of induced electric field inside the nerve during magnetic stimulation. In the past, homogeneous models were used to estimate the field profile inside conductive tissue due to the time varying current in the magnetic coil. Moreover, the effect of the surrounding media and stimulation mechanisms was understudied, which limits the optimization accuracy of the magnetic coils. In this work, we developed anatomically correct tissue models to study the effect of tissue heterogeneity and the surrounding media on the induced electric field. We also developed an optimization algorithm for designing energy efficient cm-size magnetic coils, that were then used for ex-vivo magnetic stimulation of the frog's sciatic nerve

    Applications of Antenna Technology in Sensors

    Get PDF
    During the past few decades, information technologies have been evolving at a tremendous rate, causing profound changes to our world and to our ways of living. Emerging applications have opened u[ new routes and set new trends for antenna sensors. With the advent of the Internet of Things (IoT), the adaptation of antenna technologies for sensor and sensing applications has become more important. Now, the antennas must be reconfigurable, flexible, low profile, and low-cost, for applications from airborne and vehicles, to machine-to-machine, IoT, 5G, etc. This reprint aims to introduce and treat a series of advanced and emerging topics in the field of antenna sensors

    Analysis of relevant technical issues and deficiencies of the existing sensors and related initiatives currently set and working in marine environment. New generation technologies for cost-effective sensors

    Get PDF
    The last decade has seen significant growth in the field of sensor networks, which are currently collecting large amounts of environmental data. This data needs to be collected, processed, stored and made available for analysis and interpretation in a manner which is meaningful and accessible to end users and stakeholders with a range of requirements, including government agencies, environmental agencies, the research community, industry users and the public. The COMMONSENSE project aims to develop and provide cost-effective, multi-functional innovative sensors to perform reliable in-situ measurements in the marine environment. The sensors will be easily usable across several platforms, and will focus on key parameters including eutrophication, heavy metal contaminants, marine litter (microplastics) and underwater noise descriptors of the MSFD. The aims of Tasks 2.1 and 2.2 which comprise the work of this deliverable are: • To obtain a comprehensive understanding and an up-to-date state of the art of existing sensors. • To provide a working basis on “new generation” technologies in order to develop cost-effective sensors suitable for large-scale production. This deliverable will consist of an analysis of state-of-the-art solutions for the different sensors and data platforms related with COMMONSENSE project. An analysis of relevant technical issues and deficiencies of existing sensors and related initiatives currently set and working in marine environment will be performed. Existing solutions will be studied to determine the main limitations to be considered during novel sensor developments in further WP’s. Objectives & Rationale The objectives of deliverable 2.1 are: • To create a solid and robust basis for finding cheaper and innovative ways of gathering data. This is preparatory for the activities in other WPs: for WP4 (Transversal Sensor development and Sensor Integration), for WP(5-8) (Novel Sensors) to develop cost-effective sensors suitable for large-scale production, reducing costs of data collection (compared to commercially available sensors), increasing data access availability for WP9 (Field testing) when the deployment of new sensors will be drawn and then realized
    corecore