19 research outputs found

    ULTRALOW-POWER, LOW-VOLTAGE DIGITAL CIRCUITS FOR BIOMEDICAL SENSOR NODES

    Get PDF
    Ph.DDOCTOR OF PHILOSOPH

    ULTRA LOW POWER CIRCUITS FOR WEARABLE BIOMEDICAL SENSORS

    Get PDF
    Ph.DDOCTOR OF PHILOSOPH

    Design of a Programmable Passive SoC for Biomedical Applications Using RFID ISO 15693/NFC5 Interface

    Get PDF
    Low power, low cost inductively powered passive biotelemetry system involving fully customized RFID/NFC interface base SoC has gained popularity in the last decades. However, most of the SoCs developed are application specific and lacks either on-chip computational or sensor readout capability. In this paper, we present design details of a programmable passive SoC in compliance with ISO 15693/NFC5 standard for biomedical applications. The integrated system consists of a 32-bit microcontroller, a sensor readout circuit, a 12-bit SAR type ADC, 16 kB RAM, 16 kB ROM and other digital peripherals. The design is implemented in a 0.18 μ m CMOS technology and used a die area of 1.52 mm × 3.24 mm. The simulated maximum power consumption of the analog block is 592 μ W. The number of external components required by the SoC is limited to an external memory device, sensors, antenna and some passive components. The external memory device contains the application specific firmware. Based on the application, the firmware can be modified accordingly. The SoC design is suitable for medical implants to measure physiological parameters like temperature, pressure or ECG. As an application example, the authors have proposed a bioimplant to measure arterial blood pressure for patients suffering from Peripheral Artery Disease (PAD)

    Design and Implementation of Complexity Reduced Digital Signal Processors for Low Power Biomedical Applications

    Get PDF
    Wearable health monitoring systems can provide remote care with supervised, inde-pendent living which are capable of signal sensing, acquisition, local processing and transmission. A generic biopotential signal (such as Electrocardiogram (ECG), and Electroencephalogram (EEG)) processing platform consists of four main functional components. The signals acquired by the electrodes are amplified and preconditioned by the (1) Analog-Front-End (AFE) which are then digitized via the (2) Analog-to-Digital Converter (ADC) for further processing. The local digital signal processing is usually handled by a custom designed (3) Digital Signal Processor (DSP) which is responsible for either anyone or combination of signal processing algorithms such as noise detection, noise/artefact removal, feature extraction, classification and compres-sion. The digitally processed data is then transmitted via the (4) transmitter which is renown as the most power hungry block in the complete platform. All the afore-mentioned components of the wearable systems are required to be designed and fitted into an integrated system where the area and the power requirements are stringent. Therefore, hardware complexity and power dissipation of each functional component are crucial aspects while designing and implementing a wearable monitoring platform. The work undertaken focuses on reducing the hardware complexity of a biosignal DSP and presents low hardware complexity solutions that can be employed in the aforemen-tioned wearable platforms. A typical state-of-the-art system utilizes Sigma Delta (Σ∆) ADCs incorporating a Σ∆ modulator and a decimation filter whereas the state-of-the-art decimation filters employ linear phase Finite-Impulse-Response (FIR) filters with high orders that in-crease the hardware complexity [1–5]. In this thesis, the novel use of minimum phase Infinite-Impulse-Response (IIR) decimators is proposed where the hardware complexity is massively reduced compared to the conventional FIR decimators. In addition, the non-linear phase effects of these filters are also investigated since phase non-linearity may distort the time domain representation of the signal being filtered which is un-desirable effect for biopotential signals especially when the fiducial characteristics carry diagnostic importance. In the case of ECG monitoring systems the effect of the IIR filter phase non-linearity is minimal which does not affect the diagnostic accuracy of the signals. The work undertaken also proposes two methods for reducing the hardware complexity of the popular biosignal processing tool, Discrete Wavelet Transform (DWT). General purpose multipliers are known to be hardware and power hungry in terms of the number of addition operations or their underlying building blocks like full adders or half adders required. Higher number of adders leads to an increase in the power consumption which is directly proportional to the clock frequency, supply voltage, switching activity and the resources utilized. A typical Field-Programmable-Gate-Array’s (FPGA) resources are Look-up Tables (LUTs) whereas a custom Digital Signal Processor’s (DSP) are gate-level cells of standard cell libraries that are used to build adders [6]. One of the proposed methods is the replacement of the hardware and power hungry general pur-pose multipliers and the coefficient memories with reconfigurable multiplier blocks that are composed of simple shift-add networks and multiplexers. This method substantially reduces the resource utilization as well as the power consumption of the system. The second proposed method is the design and implementation of the DWT filter banks using IIR filters which employ less number of arithmetic operations compared to the state-of-the-art FIR wavelets. This reduces the hardware complexity of the analysis filter bank of the DWT and can be employed in applications where the reconstruction is not required. However, the synthesis filter bank for the IIR wavelet transform has a higher computational complexity compared to the conventional FIR wavelet synthesis filter banks since re-indexing of the filtered data sequence is required that can only be achieved via the use of extra registers. Therefore, this led to the proposal of a novel design which replaces the complex IIR based synthesis filter banks with FIR fil-ters which are the approximations of the associated IIR filters. Finally, a comparative study is presented where the hybrid IIR/FIR and FIR/FIR wavelet filter banks are de-ployed in a typical noise reduction scenario using the wavelet thresholding techniques. It is concluded that the proposed hybrid IIR/FIR wavelet filter banks provide better denoising performance, reduced computational complexity and power consumption in comparison to their IIR/IIR and FIR/FIR counterparts

    PROCESS AWARE ANALOG-CENTRIC SINGLE LEAD ECG ACQUISITION AND CLASSIFICATION CMOS FRONTEND

    Get PDF
    The primary objective of this research work is the development of a low power single-lead ECG analog front-end (AFE) architecture which includes acquisition, digitization, process aware efficient gain and frequency control mechanism and a low complexity classifier for the detecting asystole, extreme bardycardia and tachycardia. Recent research on ECG recording systems focuses on the design of a compact single-lead wearable/portable devices with ultra-low-power consumption and in-built hardware for diagnosis and prognosis. Since, the amplitude of the ECG signal varies from hundreds of µV to a few mV, and has a bandwidth of DC to 250 Hz, conventional front-ends use an instrument amplifier followed by a programmable gain amplifier (PGA) to amplify the input ECG signal appropriately. This work presents an mixed signal ECG fronted with an ultra-low power two-stage capacitive-coupled signal conditioning circuit (or an AFE), providing programmable amplification along with tunable 2nd order high pass and lowpass filter characteristics. In the contemporary state-of-the-art ECG recording systems, the gain of the amplifier is controlled by external digital control pins which are in turn dynamically controlled through a DSP. Therefore, an efficient automatic gain control mechanism with minimal area overhead and consuming power in the order of nano watts only. The AGC turns the subsequent ADC on only after output of the PGA (or input of the ADC) reaches a level for which the ADC achieves maximum signal-to-noise-ratio (SNR), hence saving considerable startup power and avoiding the use of DSP. Further, in any practical filter design, the low pass cut-off frequency is prone to deviate from its nominal value across process and temperature variations. Therefore, post-fabrication calibration is essential, before the signal is fed to an ADC, to minimize this deviation, prevent signal degradation due to aliasing of higher frequencies into the bandwidth for classification of ECG signals, to switch to low resolution processing, hence saving power and enhances battery lifetime. Another short-coming noticed in the literature published so far is that the classification algorithm is implemented in digital domain, which turns out to be a power hungry approach. Moreover, Although analog domain implementations of QRS complexes detection schemes have been reported, they employ an external micro-controller to determine the threshold voltage. In this regard, finally a power-efficient low complexity CMOS fully analog classifier architecture and a heart rate estimator is added to the above scheme. It reduces the overall system power consumption by reducing the computational burden on the DSP. The complete proposed scheme consists of (i) an ultra-low power QRS complex detection circuit using an autonomous dynamic threshold voltage, hence discarding the need of any external microcontroller/DSP and calibration (ii) a power efficient analog classifier for the detection of three critical alarm types viz. asystole, extreme bradycardia and tachycardia. Additionally, a heart rate estimator that provides the number of QRS complexes within a period of one minute for cardiac rhythm (CR) and heart rate variability (HRV) analysis. The complete proposed architecture is implemented in UMC 0.18 µm CMOS technology with 1.8 V supply. The functionality of each of the individual blocks are successfully validated using postextraction process corner simulations and through real ECG test signals taken from the PhysioNet database. The capacitive feedback amplifier, Σ∆ ADC, AGC and the AFT are fabricated, and the measurement results are discussed here. The analog classification scheme is successfully validated using embed NXP LPC1768 board, discrete peak detector prototype and FPGA software interfac

    LOW- VOLTAGE HIGH EFFICIENCY ANALOG-TO-DIGITAL CONVERTER FOR BIOMEDICAL SENSOR INTERFACE

    Get PDF
    Ph.DDOCTOR OF PHILOSOPH

    Ultra-low-power circuits and systems for wearable and implantable medical devices

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2013.Cataloged from PDF version of thesis.Includes bibliographical references (pages 219-231).Advances in circuits, sensors, and energy storage elements have opened up many new possibilities in the health industry. In the area of wearable devices, the miniaturization of electronics has spurred the rapid development of wearable vital signs, activity, and fitness monitors. Maximizing the time between battery recharge places stringent requirements on power consumption by the device. For implantable devices, the situation is exacerbated by the fact that energy storage capacity is limited by volume constraints, and frequent battery replacement via surgery is undesirable. In this case, the design of energy-efficient circuits and systems becomes even more crucial. This thesis explores the design of energy-efficient circuits and systems for two medical applications. The first half of the thesis focuses on the design and implementation of an ultra-low-power, mixed-signal front-end for a wearable ECG monitor in a 0.18pm CMOS process. A mixed-signal architecture together with analog circuit optimizations enable ultra-low-voltage operation at 0.6V which provides power savings through voltage scaling, and ensures compatibility with state-of-the-art DSPs. The fully-integrated front-end consumes just 2.9[mu]W, which is two orders of magnitude lower than commercially available parts. The second half of this thesis focuses on ultra-low-power system design and energy-efficient neural stimulation for a proof-of-concept fully-implantable cochlear implant. First, implantable acoustic sensing is demonstrated by sensing the motion of a human cadaveric middle ear with a piezoelectric sensor. Second, alternate energy-efficient electrical stimulation waveforms are investigated to reduce neural stimulation power when compared to the conventional rectangular waveform. The energy-optimal waveform is analyzed using a computational nerve fiber model, and validated with in-vivo ECAP recordings in the auditory nerve of two cats and with psychophysical tests in two human cochlear implant users. Preliminary human subject testing shows that charge and energy savings of 20-30% and 15-35% respectively are possible with alternative waveforms. A system-on-chip comprising the sensor interface, reconfigurable sound processor, and arbitrary-waveform neural stimulator is implemented in a 0.18[mu]m high-voltage CMOS process to demonstrate the feasibility of this system. The sensor interface and sound processor consume just 12[mu]W of power, representing just 2% of the overall system power which is dominated by stimulation. As a result, the energy savings from using alternative stimulation waveforms transfer directly to the system.by Marcus Yip.Ph.D

    Design techniques for smart and energy-efficient wireless body sensor networks

    Get PDF
    Tesis inédita de la Universidad Complutense de Madrid, Facultad de Informática, Departamento de Arquitectura de Computadores y Automática, leída el 26/10/2012Las redes inalámbricas de sensores corporales (en inglés: "wireless body sensor networks" o WBSNs) para monitorización, diagnóstico y detección de emergencias, están ganando popularidad y están llamadas a cambiar profundamente la asistencia sanitaria en los próximos años. El uso de estas redes permite una supervisión continua, contribuyendo a la prevención y el diagnóstico precoz de enfermedades, al tiempo que mejora la autonomía del paciente con respecto a otros sistemas de monitorización actuales. Valiéndose de esta tecnología, esta tesis propone el desarrollo de un sistema de monitorización de electrocardiograma (ECG), que no sólo muestre continuamente el ECG del paciente, sino que además lo analice en tiempo real y sea capaz de dar información sobre el estado del corazón a través de un dispositivo móvil. Esta información también puede ser enviada al personal médico en tiempo real. Si ocurre un evento peligroso, el sistema lo detectará automáticamente e informará de inmediato al paciente y al personal médico, posibilitando una rápida reacción en caso de emergencia. Para conseguir la implementación de dicho sistema, se desarrollan y optimizan distintos algoritmos de procesamiento de ECG en tiempo real, que incluyen filtrado, detección de puntos característicos y clasificación de arritmias. Esta tesis también aborda la mejora de la eficiencia energética de la red de sensores, cumpliendo con los requisitos de fidelidad y rendimiento de la aplicación. Para ello se proponen técnicas de diseño para reducir el consumo de energía, que permitan buscar un compromiso óptimo entre el tamaño de la batería y su tiempo de vida. Si el consumo de energía puede reducirse lo suficiente, sería posible desarrollar una red que funcione permanentemente. Por lo tanto, el muestreo, procesamiento, almacenamiento y transmisión inalámbrica tienen que hacerse de manera que se suministren todos los datos relevantes, pero con el menor consumo posible de energía, minimizando así el tamaño de la batería (que condiciona el tamaño total del nodo) y la frecuencia de recarga de la batería (otro factor clave para su usabilidad). Por lo tanto, para lograr una mejora en la eficiencia energética del sistema de monitorización y análisis de ECG propuesto en esta tesis, se estudian varias soluciones a nivel de control de acceso al medio y sistema operativo.Depto. de Arquitectura de Computadores y AutomáticaFac. de InformáticaTRUEunpu

    Printed Spiral Coil Design, Implementation, And Optimization For 13.56 MHz Near-Field Wireless Resistive Analog Passive (WRAP) Sensors

    Get PDF
    Noroozi, Babak. Ph.D. The University of Memphis. June 2020. Printed Spiral Coil Design, Implementation, and Optimization for 13.56 MHz Near-Field Wireless Resistive Analog Passive (WRAP) Sensors. Major Professor: Dr. Bashir I. Morshed.Monitoring the bio-signals in the regular daily activities for a long time can embrace many benefits for the patients, caregivers, and healthcare system. Early diagnosis of diseases prior to the onset of serious symptoms gives more time to take some preventive action and to begin effective treatment with lower cost. These health and economy benefits are achievable with a user-friendly, low-cost, and unobtrusive wearable sensor that can easily be carried by a patient with no interference with the normal life. The easy application of such sensor brings the smart and connected community (SCC) idea to existence. The spread of a designated disease, like COVID-19, can be studied by collecting the physiological signals transmitted from the wearable sensors in conjunction with a mobile app interface. Moreover, such a comfortable wearable sensor can help to monitor the vital signals during fitness activities for workout concerns. The desire of such wearable sensor has been responded in many researches and commercial products such as smart watch and Fitbit. Wireless connection between the sensor on the body and the scanner is the key and common factor of all convenient wearables. This essential feature has been currently addressed by the costly techniques which is the main impediment to be widely applicable. The existing wireless methods including WiFi, Bluetooth, RFID, and NFC impose cost, complexity, weight, and extra maintenance including battery replacement or recharging, which drove us to propose a low-cost, convenient, and simple technique for wireless connection suitable for battery-less fully-passive sensors. Using a pair of coils connected by the near-field magnetic induction has been copiously used in wireless power transfer (WPT) for medical and industrial applications. However, near field RFID and NFC rely on this technique with active circuits. In contrast, we have proposed a wireless resistive analog passive (WRAP) sensor in which a resistive transducer at the secondary side, affects the primary quality factor (Q) through the inductive connection between a pair of square-shaped Printed Spiral Coils (PSC). The primary 13.56 MHz (ISM band) signal is modulated in response to the continuous change of bio-signal and the amount of response to the unit change in transducer resistance is defined as sensitivity. A higher sensitivity enables the system to respond to the smaller bio-signals and increases the coils maximum relative mobilities. The PSCs specifications and circuit components determine the sensitivity and its tolerance to the coils displacements. We first define and formulize the objective function for coil and components optimization to achieve the maximum sensitivity. Although the optimization methods do not show much different results, due to the speed and simplicity, the Genetic Algorithm (GA) technique is chosen as an advanced method. Then in second optimization stage, the axial and lateral distances that affect the mutual inductance are introduced to the optimization process. The results as a pair of PSCs profiles and the associated circuit components are obtained and fabricated that produced the maximum sensitivity and misalignment tolerance. For the sake of patient comfort, the secondary coil size is fixed at 20 mm and the primary coil is optimized at 60 mm with the maximum (normalized) sensitivity 1.3 m for 16 mm axial distance. If the Read-Zone is defined as the space in which the center of secondary coil can move and the sensitivity keeps at least half of its maximum value, the best Read-Zone has a conical shape with the base radius 22.5 mm and height 14 mm. The analytical results are verified by the measurement results on the fabricated coils and circuits

    Analog Compressive Sensing for Multi-Channel Neural Recording: Modeling and Circuit Level Implementation

    Get PDF
    RÉSUMÉ Dans cette thèse, nous présentons la conception d’un implant d’enregistrement neuronal multicanaux avec un échantillonnage compressé mis en oeuvre avec un procédé de fabrication CMOS à 65 nm. La réduction de la technologie a˙ecte à la baisse les paramètres des amplificateurs neuronaux couplés en AC, comme la fréquence de coupure basse, en raison de l’e˙et de canal court des transistors MOS. Nous analysons la fréquence de coupure basse et nous constatons que l’origine de ce problème, dans les technologies avancées, est la diminution de l’impédance d’entrée de l’amplificateur opérationnel de transconductance (OTA) en raison de la fuite d’oxyde de grille à l’entrée des OTA. Nous proposons deux solutions pour réduire la fréquence de coupure basse sans augmenter la valeur des condensateurs de rétroaction de l’étage d’entrée. La première solution est appelée rétroaction positive croisée et la deuxième solution utilise des PMOS à oxyde épais dans la paire de l’entrée di˙érentielle de l’OTA. Il est à noter que pour compresser le signal neuronal, nous utilisons le CS dans le domaine analogique. Pour la réalisation, un intégrateur à capacité commutée est requis. Les paramètres non idéaux de l’OTA utilisé dans cet intégrateur, tels que le gain fini, la bande passante, la vitesse de balayage et le changement rapide de la sortie. Toutes ces imperfections induisent des erreurs et réduisent le rapport signal sur bruit (SNR) total. Nous avons simulé ces imperfections sur Matlab et Simulink pour définir les spécifications de l’OTA requis. Aussi, pour concevoir les circuits analogiques correspondant aux interfaces neuronales requises, tels qu’un amplificateur neuronal, une référence de tension compacte et à faible consommation d’énergie est requise. Nous avons proposé une référence de tension de faible consommation d’énergie sans utiliser le transistor bipolaire parasite de la technologie CMOS pour diminuer la surface de silicium requise. Finalement, nous avons complété l’encodeur de CS et un convertisseur analogique-numérique à approximation successive (SAR ADC) requis pour la chaine d’enregistrement des signaux neuronaux dans ce projet.----------ABSTRACT In this thesis we present the design of a multi-channel neural recording implant with analog compressive sensing (CS) in 65 nm process. Scaling down technology demotes the parameters of AC-coupled neural amplifiers, such as increasing the low-cuto˙ frequency due to the short-channel e˙ects of MOS transistors. We analyze the low-cuto˙ frequency and find that the main reason of this problem in advanced technologies is decreasing the input resistance of the operational transconductance amplifier (OTA) due to the gate oxide static current leakage in the input of the OTA. In advanced technologies, the gate oxide is thin and some electrons can penetrate to the channel and cause DC current leakage. We proposed two solutions to reduce the low-cuto˙ frequency without increasing the value of the feedback capacitors of the front-end neural amplifier. The first solution is called cross-coupled positive feedback, and the second solution is utilizing thick-oxide PMOS transistors in the input di˙erential pair of the OTA. Compress the neural signal, we utilized the CS method in analog domain. For its implementation, a switched-capacitor integrator is required. Non-ideal specifications of OTA of CS integrator such as finite gain, bandwidth, slew rate and output swing induce error and reduce the total signal to noise ratio (SNR). We simulated these non-idealities in Matlab and Simulink and extracted the specification of the required OTA. Also, to design analog circuits such as neural amplifier a low power and compact voltage reference is required. We implemented a low-power band-gap reference without utilizing parasitic bipolar transis-tor to decrease the silicon area. At the end, we completed the CS encoder and successive approximation architecture analog-to-digital converter (SAR ADC)