    Physiological sensor.

    Get PDF
    For the purpose of medical diagnosis and research, various physiological signals, such as Photoplethysmograph (PPG), Galvanic Skin Response (GSR) and Skin Temperature (SKT), are measured by different types of medical sensor equipment. However, the sensors are intrusive and the patients must endure some discomfort when encountering these types of medical sensor equipment. These bio sensors also fail to be implemented outside of lab or clinical settings. Recently the development in sensor technology and wireless communication technology have significantly improved the integration of wearable systems, so that we could find new ways to minimize the wearable circuits module, design layers of fabric for wearable system. This thesis documents the successful development of a novel, unobtrusive, low-cost, wrist-worn integrated sensors (PPG, GSR, SKT) system using wireless wearable technology capable of measuring real-time data collection, and monitoring which is important when dealing with treatment and management of many chronic illnesses, neurological disorders, and mental health issues. Examples can include: epileptic seizures, autism spectrum disorder (ASD), depression, drug addiction, and anxiety disorders

    Effects of Motion Sickness on Encoding and Retrieval Performance and on Psychophysiological Responses

    Get PDF
    Background: Motion sickness has previously been found to deteriorate performance. In complex working environments, sustained ability to perform despite motion sickness is crucial. This study focuses on effects of motion sickness on encoding and retrieval of words. In addition, the temporal development of psychophysiological responses and their relationship with perceived motion sickness were investigated. Methods: Forty healthy participants (20 male and 20 female, age 19-51) performed an encoding and retrieval task during exposure to an optokinetic drum and were compared with 20 controls (8 male and 12 female, age 21-47) not exposed to motion sickness. Measurements of heart rate, heart rate variability, skin conductance, blood volume pulse, respiration rate, and skin temperature were made throughout optokinetic drum exposure. Results: Moderate levels of motion sickness did not affect the ability to encode or retrieve words. Perceived motion sickness was positively related to heart rate, blood volume pulse and skin temperature and negatively related to respiration rate. Conclusions: The psychophysiological measurements did not show consistent patterns of sympathetic activation and parasympathetic withdrawal, as could be expected. Subjective reports of progressing symptoms are still likely to be the most reliable way of assessing motion sickness

    Multivariate correlation measures reveal structure and strength of brain–body physiological networks at rest and during mental stress

    Get PDF
    In this work, we extend to the multivariate case the classical correlation analysis used in the field of network physiology to probe dynamic interactions between organ systems in the human body. To this end, we define different correlation-based measures of the multivariate interaction (MI) within and between the brain and body subnetworks of the human physiological network, represented, respectively, by the time series of delta, theta, alpha, and beta electroencephalographic (EEG) wave amplitudes, and of heart rate, respiration amplitude, and pulse arrival time (PAT) variability (eta, rho, pi). MI is computed: (i) considering all variables in the two subnetworks to evaluate overall brain-body interactions; (ii) focusing on a single target variable and dissecting its global interaction with all other variables into contributions arising from the same subnetwork and from the other subnetwork; and (iii) considering two variables conditioned to all the others to infer the network topology. The framework is applied to the time series measured from the EEG, electrocardiographic (ECG), respiration, and blood volume pulse (BVP) signals recorded synchronously via wearable sensors in a group of healthy subjects monitored at rest and during mental arithmetic and sustained attention tasks. We find that the human physiological network is highly connected, with predominance of the links internal of each subnetwork (mainly eta-rho and delta-theta, theta-alpha, alpha-beta), but also statistically significant interactions between the two subnetworks (mainly eta-beta and eta-delta). MI values are often spatially heterogeneous across the scalp and are modulated by the physiological state, as indicated by the decrease of cardiorespiratory interactions during sustained attention and by the increase of brain-heart interactions and of brain-brain interactions at the frontal scalp regions during mental arithmetic. These findings illustrate the complex and multi-faceted structure of interactions manifested within and between different physiological systems and subsystems across different levels of mental stress

    Automatic Pain Assessment by Learning from Multiple Biopotentials

    Get PDF
    Kivun täsmällinen arviointi on tärkeää kivunhallinnassa, erityisesti sairaan- hoitoa vaativille ipupotilaille. Kipu on subjektiivista, sillä se ei ole pelkästään aistituntemus, vaan siihen saattaa liittyä myös tunnekokemuksia. Tällöin itsearviointiin perustuvat kipuasteikot ovat tärkein työkalu, niin auan kun potilas pystyy kokemuksensa arvioimaan. Arviointi on kuitenkin haasteellista potilailla, jotka eivät itse pysty kertomaan kivustaan. Kliinisessä hoito- työssä kipua pyritään objektiivisesti arvioimaan esimerkiksi havainnoimalla fysiologisia muuttujia kuten sykettä ja käyttäytymistä esimerkiksi potilaan kasvonilmeiden perusteella. Tutkimuksen päätavoitteena on automatisoida arviointiprosessi hyödyntämällä koneoppimismenetelmiä yhdessä biosignaalien prosessointnin kanssa. Tavoitteen saavuttamiseksi mitattiin autonomista keskushermoston toimintaa kuvastavia biopotentiaaleja: sydänsähkökäyrää, galvaanista ihoreaktiota ja kasvolihasliikkeitä mittaavaa lihassähkökäyrää. Mittaukset tehtiin terveillä vapaaehtoisilla, joille aiheutettiin kokeellista kipuärsykettä. Järestelmän kehittämiseen tarvittavaa tietokantaa varten rakennettiin biopotentiaaleja keräävä Internet of Things -pohjainen tallennusjärjestelmä. Koostetun tietokannan avulla kehitettiin biosignaaleille prosessointimenetelmä jatku- vaan kivun arviointiin. Signaaleista eroteltiin piirteitä sekuntitasoon mukautetuilla aikaikkunoilla. Piirteet visualisoitiin ja tarkasteltiin eri luokittelijoilla kivun ja kiputason tunnistamiseksi. Parhailla luokittelumenetelmillä saavutettiin kivuntunnistukseen 90% herkkyyskyky (sensitivity) ja 84% erottelukyky (specificity) ja kivun voimakkuuden arviointiin 62,5% tarkkuus (accuracy). Tulokset vahvistavat kyseisen käsittelytavan käyttökelpoisuuden erityis- esti tunnistettaessa kipua yksittäisessä arviointi-ikkunassa. Tutkimus vahvistaa biopotentiaalien avulla kehitettävän automatisoidun kivun arvioinnin toteutettavuuden kokeellisella kivulla, rohkaisten etenemään todellisen kivun tutkimiseen samoilla menetelmillä. Menetelmää kehitettäessä suoritettiin lisäksi vertailua ja yhteenvetoa automaattiseen kivuntunnistukseen kehitettyjen eri tutkimusten välisistä samankaltaisuuksista ja eroista. Tarkastelussa löytyi signaalien eroavaisuuksien lisäksi tutkimusmuotojen aiheuttamaa eroa arviointitavoitteisiin, mikä hankaloitti tutkimusten vertailua. Lisäksi pohdit- tiin mitkä perinteisten prosessointitapojen osiot rajoittavat tai edistävät ennustekykyä ja miten, sekä tuoko optimointi läpimurtoa järjestelmän näkökulmasta.Accurate pain assessment plays an important role in proper pain management, especially among hospitalized people experience acute pain. Pain is subjective in nature which is not only a sensory feeling but could also combine affective factors. Therefore self-report pain scales are the main assessment tools as long as patients are able to self-report. However, it remains a challenge to assess the pain from the patients who cannot self-report. In clinical practice, physiological parameters like heart rate and pain behaviors including facial expressions are observed as empirical references to infer pain objectively. The main aim of this study is to automate such process by leveraging machine learning methods and biosignal processing. To achieve this goal, biopotentials reflecting autonomic nervous system activities including electrocardiogram and galvanic skin response, and facial expressions measured with facial electromyograms were recorded from healthy volunteers undergoing experimental pain stimulus. IoT-enabled biopotential acquisition systems were developed to build the database aiming at providing compact and wearable solutions. Using the database, a biosignal processing flow was developed for continuous pain estimation. Signal features were extracted with customized time window lengths and updated every second. The extracted features were visualized and fed into multiple classifiers trained to estimate the presence of pain and pain intensity separately. Among the tested classifiers, the best pain presence estimating sensitivity achieved was 90% (specificity 84%) and the best pain intensity estimation accuracy achieved was 62.5%. The results show the validity of the proposed processing flow, especially in pain presence estimation at window level. This study adds one more piece of evidence on the feasibility of developing an automatic pain assessment tool from biopotentials, thus providing the confidence to move forward to real pain cases. In addition to the method development, the similarities and differences between automatic pain assessment studies were compared and summarized. It was found that in addition to the diversity of signals, the estimation goals also differed as a result of different study designs which made cross dataset comparison challenging. We also tried to discuss which parts in the classical processing flow would limit or boost the prediction performance and whether optimization can bring a breakthrough from the system’s perspective

    Robust Algorithms for Unattended Monitoring of Cardiovascular Health

    Get PDF
    Cardiovascular disease is the leading cause of death in the United States. Tracking daily changes in one’s cardiovascular health can be critical in diagnosing and managing cardiovascular disease, such as heart failure and hypertension. A toilet seat is the ideal device for monitoring parameters relating to a subject’s cardiac health in his or her home, because it is used consistently and requires no change in daily habit. The present work demonstrates the ability to accurately capture clinically relevant ECG metrics, pulse transit time based blood pressures, and other parameters across subjects and physiological states using a toilet seat-based cardiovascular monitoring system, enabled through advanced signal processing algorithms and techniques. The algorithms described herein have been designed for use with noisy physiologic signals measured at non-standard locations. A key component of these algorithms is the classification of signal quality, which allows automatic rejection of noisy segments before feature delineation and interval extractions. The present delineation algorithms have been designed to work on poor quality signals while maintaining the highest possible temporal resolution. When validated on standard databases, the custom QRS delineation algorithm has best-in-class sensitivity and precision, while the photoplethysmogram delineation algorithm has best-in-class temporal resolution. Human subject testing on normative and heart failure subjects is used to evaluate the efficacy of the proposed monitoring system and algorithms. Results show that the accuracy of the measured heart rate and blood pressure are well within the limits of AAMI standards. For the first time, a single device is capable of monitoring long-term trends in these parameters while facilitating daily measurements that are taken at rest, prior to the consumption of food and stimulants, and at consistent times each day. This system has the potential to revolutionize in-home cardiovascular monitoring

    A wearable heart monitor at the ear using ballistocardiogram (BCG) and electrocardiogram (ECG) with a nanowatt ECG heartbeat detection circuit

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2013.Cataloged from PDF version of thesis.Includes bibliographical references (p. 132-137).This work presents a wearable heart monitor at the ear that uses the ballistocardiogram (BCG) and the electrocardiogram (ECG) to extract heart rate, stroke volume, and pre-ejection period (PEP) for the application of continuous heart monitoring. Being a natural anchoring point, the ear is demonstrated as a viable location for the integrated sensing of physiological signals. The source of periodic head movements is identified as a type of BCG, which is measured using an accelerometer. The head BCG's principal peaks (J-waves) are synchronized to heartbeats. Ensemble averaging is used to obtain consistent J-wave amplitudes, which are related to stroke volume. The ECG is sensed locally near the ear using a single-lead configuration. When the BCG and the ECG are used together, an electromechanical duration called the RJ interval can be obtained. Because both head BCG and ECG have low signal-to-noise ratios, cross-correlation is used to statistically extract the RJ interval. The ear-worn device is wirelessly connected to a computer for real time data recording. A clinical test involving hemodynamic maneuvers is performed on 13 subjects. The results demonstrate a linear relationship between the J-wave amplitude and stroke volume, and a linear relationship between the RJ interval and PEP. While the clinical device uses commercial components, a custom integrated circuit for ECG heartbeat detection is designed with the goal of reducing power consumption and device size. With 58nW of power consumption, the ECG circuit replaces the traditional instrumentation amplifier, analog-to-digital converter, and signal processor with a single chip solution. The circuit demonstrates a topology that takes advantage of the ECG's characteristics to extract R-wave timings at the chest and the ear in the presence of baseline drift, muscle artifact, and signal clipping.by David Da He.Ph.D

    Exploring Perovskite Photodiodes:Device Physics and Applications

    Get PDF

    Exploring Perovskite Photodiodes:Device Physics and Applications

    Get PDF

    Psychophysiology in the digital age

    Get PDF
    The research I performed for my thesis revolved around the question how affect-physiology dynamics can be best measured in daily life. In my thesis I focused on three aspects of this question: 1) Do wearable wristband devices have sufficient validity to capture ANS activity? 2) To what extent is the laboratory design suitable to measure affect-ANS dynamics? 3) Are the affect-ANS dynamics subject to individual differences, both in the laboratory and in daily life? In chapter 2, I validated a shortened version of the Sing-a-Song Stress (SSST) test, the SSSTshort. The purpose of this test is to create social-evaluative stress in participants through a simple and brief design that does not require the involvement of multiple confederates. The results indicated that the SSSTshort was effective in inducing ANS and affective reactivity. This makes the SSSTshort a cost-effective alternative to the well-known Trier-Social-Stress task (TSST), which can be easily incorporated into large-scale studies to expand the range of stress types that can be studied in laboratory designs. In chapter 3, I validated a new wrist worn technology for measuring electrodermal activity (EDA). As expected, the overall EDA levels measured on the wrist were lower than those measured on the palm, likely due to the lower density of sweat glands on the wrist. The analysis demonstrated that the frequency measure of non-specific skin conductance response (ns.SCR) was superior to the commonly used measure of skin conductance level (SCL) for both the palm and wrist. The wrist-based ns.SCR measure was sensitive to the experimental manipulations and showed similar correspondence to the pre-ejection period (PEP) as palm-based ns.SCR. Moreover, wrist-based ns.SCR demonstrated similar predictive validity for affective state as PEP. However, the predictive validity of both wrist-based ns.SCR and PEP was lower compared to palm-based ns.SCR. These findings suggest that wrist-based ns.SCR EDA parameter has a promising future for use in psychophysiological research. In Chapter 4 of my thesis, I conducted the first study to directly compare the relationship between affect and ANS activity in a laboratory setting to that in daily life. To elicit stress in the laboratory, four different stress paradigms were employed, while stressful events in daily life were left to chance. In both settings, a valence and arousal scale was constructed from a nine-item affect questionnaire, and ANS activity was collected using the same devices. Data was collected from a single population, and the affect-ANS dynamics were analyzed using the same methodology for both laboratory and daily life settings. The results showed a remarkable similarity between the laboratory and daily life affect-ANS relationships. In Chapter 5 of my thesis, I investigated the influence of individual differences in physical activity and aerobic fitness on ANS and affective stress reactivity. Previous research has yielded inconsistent results due to heterogeneity issues in the population studied, stressor type, and the way fitness was measured. My study made a unique contribution to this field by measuring physical activity in three ways: 1) as objective aerobic fitness, 2) leisure time exercise behavior, and 3) total moderate-to-vigorous exercise (including both exercise and all other regular physical activity behaviors). In addition, we measured the physiological and affective stress response in both a laboratory and daily life setting. The total amount of physical activity showed more relationships with stress reactivity compared to exercise behavior alone, suggesting that future research should include a total physical activity variable. Our results did not support the cross-stressor adaptation hypotheses, suggesting that if exercise has a stress-reducing effect, it is unlikely to be mediated by altered ANS regulation due to repeated exposure to physical stress

    OPTOELECTRONIC DEVICE FOR STRESS DETECTION

    Get PDF
    This research study aims to develop a portable, non-invasive stress monitoring system that uses near-infrared light which enables the recording of brain activities during the actual life experience memory task of a subject. This is to clarify the neurophysiological mechanism of stress response by identifying the local hemodynamic changes in human brain. Recent studies have shown that the stress response system able to influence the front part of the brain known as prefrontal cortex. In this paper, a non-invasive near-infrared spectroscopy (NIRs) technology is being studied to design a basic concept of photometric system that allows to monitor and imaging blood oxygenation through skin tissues. The proposed system is applied to human hands as proof of concept. The idea is to ensure that the photometric system can be applied at the forehead area where the level of oxygenation is expected to be higher at rest under mental stress condition. The data will be evaluated as well as the measurement and calculation made by illuminating the right wavelength towards the tissue and detects the reflected light, enabling spatially resolved spectroscopy to be carried out