117 research outputs found

    Doctor of Philosophy

    Get PDF
    dissertationThis dissertation presents results documenting advancements on the control of untethered magnetic devices, such as magnetic \microrobots" and magnetically actuated capsuleendoscopes, motivated by problems in minimally invasive medicine. This dissertationfocuses on applying rotating magnetic elds for magnetic manipulation. The contributions include advancements in the way that helical microswimmers (devices that mimicthe propulsion of bacterial agella) are controlled in the presence of gravitational forces, advancements in ways that groups of untethered magnetic devices can be dierentiated and semi-independently controlled, advancements in the way that untethered magnetic device can be controlled with a single rotating permanent magnet, and an improved understanding in the nature of the magnetic force applied to an untethered device by a rotating magnet

    Doctor of Philosophy

    Get PDF
    dissertationThis dissertation explores the design and use of an electromagnetic manipulation system that has been optimized for the dipole-eld model. This system can be used for noncontact manipulation of adjacent magnetic tools and combines the eld strength control of current electromagnetic systems with the analytical modeling of permanent-magnet systems. To design such a system, it is rst necessary to characterize how the shape of the eld source aects the shape of the magnetic eld. The magnetic eld generated by permanent magnets and electromagnets can be modeled, far from the source, using a multipole expansion. The error associated with the multipole expansion is quantied, and it is shown that, as long as the point of interest is 1.5 radii of the smallest sphere that can fully contain the magnetic source, the full expansion will have less than 1% error. If only the dipole term, the rst term in the expansion, is used, then the error is minimized for cylindrical shapes with a diameter-to-length ratio of 4=3 and for rectangular-bars with a cube. Applying the multipole expansion to electromagnets, an omnidirectional electromagnet, comprising three orthogonal solenoids and a spherical core, is designed that has minimal dipole-eld error and equal strength in all directions. Although this magnet can be constructed with any size core, the optimal design contains a spherical core with a diameter that is 60% of the outer dimension of the magnet. The resulting magnet's ability to dextrously control the eld at a point is demonstrated by rotating an endoscopic-pill mockup to drive it though a lumen and roll a permanent-magnet ball though several trajectories. Dipole elds also apply forces on adjacent magnetized objects. The ability to control these forces is demonstrated by performing position control on an orientation-constrained magnetic oat and nally by steering a permanent magnet, which is aligned with the applied dipole eld, around a rose curve

    Doctor of Philosophy

    Get PDF
    dissertationClosed-loop control of wireless capsule endoscopes is an active area of research because it would drastically improve screening of the gastrointestinal tract. Traditional endoscopic procedures are unable to view the entire gastrointestinal tract and current commercial wireless capsule endoscopes are limited in their effectiveness due to their passive nature. This dissertation advances the field of active capsule endoscopy by developing methods to localize the full six-degree-of-freedom (6-DOF) pose of a screw-type magnetic capsule while it is being propelled through a lumen (such as the small intestines) using an external rotating magnetic dipole. The same external magnetic dipole is utilized for both propulsion and localization. Hardware was designed and constructed to enable testing of the magnetic localization and propulsion methods, including a robotic end-effector used as the external actuator magnet, and a prototype capsule embedded with Hall-effect sensors. Due to the use of a rotating magnetic field for propulsion, at any given time, the capsule can be in one of three regimes: synchronously rotating with the applied field, in "step-out" where it is free to move but the external field is rotating too quickly for the capsule to remain synchronously rotating, or completely stationary. We show that it is only necessary to distinguish whether or not the capsule is synchronously rotating (i.e., a single localization method can be used for a capsule in either the step-out or stationary regimes). Two magnetic localization methods are developed. The first uses nonlinear least squares to estimate the capsule's pose when it has no (or approximately no) net motion (e.g., to find the initial capsule pose or when it is stuck in an intestinal fold). The second method estimates the 6-DOF capsule pose as it synchronously rotates with the applied magnetic field using a square-root variant of the Unscented Kalman filter. A simple process model is adopted that restricts the capsule's movement to translation along and rotation about its principle axis. The capsule is actively propelled forward or backward, but it is not actively steered, rather, steering is provided by the lumen. The propulsion parameters that transform magnetic force and torque to the capsule's spatial velocity and angular velocity are estimated with an additional square-root Unscented Kalman filter to enable the capsule to navigate heterogeneous environments such as the small intestines. An optimized localization-propulsion system is described using the two localization algorithms and prior work in screw-type magnetic capsule propulsion with a single rotating dipole field. The capsule's regime is determined and the corresponding localization method is employed. Based on the capsule's estimated pose and the current estimates of its propulsion parameters, the actuator magnet's pose relative to the capsule is optimized to maximize the capsule's forward propulsion. Using this system, our prototype magnetic capsule successfully completed U-shaped and S-shaped trajectories in fresh bovine intestines with an average forward velocity of 5.5mm/s and 3.5 mm/s, respectively. At this rate it would take approximately 18-30 minutes to traverse the 6 meters of a typical human small intestine

    Capsule endoscopy of the future: What's on the horizon?

    Get PDF
    Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today's standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years

    Study on Magnetic Control Systems of Micro-Robots

    Get PDF
    Magnetic control systems of micro-robots have recently blossomed as one of the most thrilling areas in the field of medical treatment. For the sake of learning how to apply relevant technologies in medical services, we systematically review pioneering works published in the past and divide magnetic control systems into three categories: stationary electromagnet control systems, permanent magnet control systems and mobile electromagnet control systems. Based on this, we ulteriorly analyze and illustrate their respective strengths and weaknesses. Furthermore, aiming at surmounting the instability of magnetic control system, we utilize SolidWorks2020 software to partially modify the SAMM system to make its final overall thickness attain 111 mm, which is capable to control and observe the motion of the micro-robot under the microscope system in an even better fashion. Ultimately, we emphasize the challenges and open problems that urgently need to be settled, and summarize the direction of development in this field, which plays a momentous role in the wide and safe application of magnetic control systems of micro-robots in clinic

    Master of Science

    Get PDF
    thesisUntethered magnetic devices such as magnetic capsule endoscopes, magnetic swimming microrobots, and magnetic screws, as well as tethered magnetic devices such as magnet-tipped catheters and magnet-tipped cochlear-implant electrode arrays, can be actuate

    Closed-Loop Magnetic Manipulation for Robotic Transesophageal Echocardiography

    Full text link
    This paper presents a closed-loop magnetic manipulation framework for robotic transesophageal echocardiography (TEE) acquisitions. Different from previous work on intracorporeal robotic ultrasound acquisitions that focus on continuum robot control, we first investigate the use of magnetic control methods for more direct, intuitive, and accurate manipulation of the distal tip of the probe. We modify a standard TEE probe by attaching a permanent magnet and an inertial measurement unit sensor to the probe tip and replacing the flexible gastroscope with a soft tether containing only wires for transmitting ultrasound signals, and show that 6-DOF localization and 5-DOF closed-loop control of the probe can be achieved with an external permanent magnet based on the fusion of internal inertial measurement and external magnetic field sensing data. The proposed method does not require complex structures or motions of the actuator and the probe compared with existing magnetic manipulation methods. We have conducted extensive experiments to validate the effectiveness of the framework in terms of localization accuracy, update rate, workspace size, and tracking accuracy. In addition, our results obtained on a realistic cardiac tissue-mimicking phantom show that the proposed framework is applicable in real conditions and can generally meet the requirements for tele-operated TEE acquisitions.Comment: Accepted by IEEE Transactions on Robotics. Copyright may be transferred without notice, after which this version may no longer be accessibl

    Magnetic Surgical Instruments for Robotic Abdominal Surgery.

    Get PDF
    This review looks at the implementation of magnetic-based approaches in surgical instruments for abdominal surgeries. As abdominal surgical techniques advance toward minimizing surgical trauma, surgical instruments are enhanced to support such an objective through the exploration of magnetic-based systems. With this design approach, surgical devices are given the capabilities to be fully inserted intraabdominally to achieve access to all abdominal quadrants, without the conventional rigid link connection with the external unit. The variety of intraabdominal surgical devices are anchored, guided, and actuated by external units, with power and torque transmitted across the abdominal wall through magnetic linkage. This addresses many constraints encountered by conventional laparoscopic tools, such as loss of triangulation, fulcrum effect, and loss/lack of dexterity for surgical tasks. Design requirements of clinical considerations to aid the successful development of magnetic surgical instruments, are also discussed

    Development of A Soft Robotic Approach for An Intra-abdominal Wireless Laparoscopic Camera

    Get PDF
    In Single-Incision Laparoscopic Surgery (SILS), the Magnetic Anchoring and Guidance System (MAGS) arises as a promising technique to provide larger workspaces and field of vision for the laparoscopes, relief space for other instruments, and require fewer incisions. Inspired by MAGS, many concept designs related to fully insertable magnetically driven laparoscopes are developed and tested on the transabdominal operation. However, ignoring the tissue interaction and insertion procedure, most of the designs adopt rigid structures, which not only damage the patients\u27 tissue with excess stress concentration and sliding motion but also require complicated operation for the insertion. Meanwhile, lacking state tracking of the insertable camera including pose and contact force, the camera systems operate in open-loop control. This provides mediocre locomotion precision and limited robustness to uncertainties in the environment. This dissertation proposes, develops, and validates a soft robotic approach for an intra-abdominal wireless laparoscopic camera. Contributions presented in this work include (1) feasibility of a soft intra-abdominal laparoscopic camera with friendly tissue interaction and convenient insertion, (2) six degrees of freedom (DOF) real-time localization, (3) Closed-loop control for a robotic-assisted laparoscopic system and (4) untethering solution for wireless communication and high-quality video transmission. Embedding magnet pairs into the camera and external actuator, the camera can be steered and anchored along the abdominal wall through transabdominal magnetic coupling. To avoid the tissue rapture by the sliding motion and dry friction, a wheel structure is applied to achieve rolling motion. Borrowing the ideas from soft robotic research, the main body of the camera implements silicone material, which grants it the bendability to passively attach along the curved abdominal wall and the deformability for easier insertion. The six-DOF pose is estimated in real-time with internal multi-sensor fusion and Newton-Raphson iteration. Combining the pose tracking and force-torque sensor measurement, an interaction model between the deformable camera and tissue is established to evaluate the interaction force over the tissue surface. Moreover, the proposed laparoscopic system is integrated with a multi-DOF manipulator into a robotic-assisted surgical system, where a closed-loop control is realized based on a feedback controller and online optimization. Finally, the wireless control and video streaming are accomplished with Bluetooth Low Energy (BLE) and Analog Video (AV) transmission. Experimental assessments have been implemented to evaluate the performance of the laparoscopic system
    • …
    corecore