405 research outputs found

    GridNet with automatic shape prior registration for automatic MRI cardiac segmentation

    Full text link
    In this paper, we propose a fully automatic MRI cardiac segmentation method based on a novel deep convolutional neural network (CNN) designed for the 2017 ACDC MICCAI challenge. The novelty of our network comes with its embedded shape prior and its loss function tailored to the cardiac anatomy. Our model includes a cardiac centerof-mass regression module which allows for an automatic shape prior registration. Also, since our method processes raw MR images without any manual preprocessing and/or image cropping, our CNN learns both high-level features (useful to distinguish the heart from other organs with a similar shape) and low-level features (useful to get accurate segmentation results). Those features are learned with a multi-resolution conv-deconv "grid" architecture which can be seen as an extension of the U-Net. Experimental results reveal that our method can segment the left and right ventricles as well as the myocardium from a 3D MRI cardiac volume in 0.4 second with an average Dice coefficient of 0.90 and an average Hausdorff distance of 10.4 mm.Comment: 8 pages, 1 tables, 2 figure

    3D cine DENSE MRI: ventricular segmentation and myocardial stratin analysis

    Get PDF
    Includes abstract. Includes bibliographical references

    Automatic segmentation of the left ventricle cavity and myocardium in MRI data

    Get PDF
    A novel approach for the automatic segmentation has been developed to extract the epi-cardium and endo-cardium boundaries of the left ventricle (lv) of the heart. The developed segmentation scheme takes multi-slice and multi-phase magnetic resonance (MR) images of the heart, transversing the short-axis length from the base to the apex. Each image is taken at one instance in the heart's phase. The images are segmented using a diffusion-based filter followed by an unsupervised clustering technique and the resulting labels are checked to locate the (lv) cavity. From cardiac anatomy, the closest pool of blood to the lv cavity is the right ventricle cavity. The wall between these two blood-pools (interventricular septum) is measured to give an approximate thickness for the myocardium. This value is used when a radial search is performed on a gradient image to find appropriate robust segments of the epi-cardium boundary. The robust edge segments are then joined using a normal spline curve. Experimental results are presented with very encouraging qualitative and quantitative results and a comparison is made against the state-of-the art level-sets method

    Multilevel comparison of deep learning models for function quantification in cardiovascular magnetic resonance: On the redundancy of architectural variations

    Get PDF
    Background: Cardiac function quantification in cardiovascular magnetic resonance requires precise contouring of the heart chambers. This time-consuming task is increasingly being addressed by a plethora of ever more complex deep learning methods. However, only a small fraction of these have made their way from academia into clinical practice. In the quality assessment and control of medical artificial intelligence, the opaque reasoning and associated distinctive errors of neural networks meet an extraordinarily low tolerance for failure. Aim: The aim of this study is a multilevel analysis and comparison of the performance of three popular convolutional neural network (CNN) models for cardiac function quantification. Methods: U-Net, FCN, and MultiResUNet were trained for the segmentation of the left and right ventricles on short-axis cine images of 119 patients from clinical routine. The training pipeline and hyperparameters were kept constant to isolate the influence of network architecture. CNN performance was evaluated against expert segmentations for 29 test cases on contour level and in terms of quantitative clinical parameters. Multilevel analysis included breakdown of results by slice position, as well as visualization of segmentation deviations and linkage of volume differences to segmentation metrics via correlation plots for qualitative analysis. Results: All models showed strong correlation to the expert with respect to quantitative clinical parameters (r(z)(') = 0.978, 0.977, 0.978 for U-Net, FCN, MultiResUNet respectively). The MultiResUNet significantly underestimated ventricular volumes and left ventricular myocardial mass. Segmentation difficulties and failures clustered in basal and apical slices for all CNNs, with the largest volume differences in the basal slices (mean absolute error per slice: 4.2 +/- 4.5 ml for basal, 0.9 +/- 1.3 ml for midventricular, 0.9 +/- 0.9 ml for apical slices). Results for the right ventricle had higher variance and more outliers compared to the left ventricle. Intraclass correlation for clinical parameters was excellent (>= 0.91) among the CNNs. Conclusion: Modifications to CNN architecture were not critical to the quality of error for our dataset. Despite good overall agreement with the expert, errors accumulated in basal and apical slices for all models

    An image segmentation and registration approach to cardiac function analysis using MRI

    No full text
    Cardiovascular diseases (CVDs) are one of the major causes of death in the world. In recent years, significant progress has been made in the care and treatment of patients with such diseases. A crucial factor for this progress has been the development of magnetic resonance (MR) imaging which makes it possible to diagnose and assess the cardiovascular function of the patient. The ability to obtain high-resolution, cine volume images easily and safely has made it the preferred method for diagnosis of CVDs. MRI is also unique in its ability to introduce noninvasive markers directly into the tissue being imaged(MR tagging) during the image acquisition process. With the development of advanced MR imaging acquisition technologies, 3D MR imaging is more and more clinically feasible. This recent development has allowed new potentially 3D image analysis technologies to be deployed. However, quantitative analysis of cardiovascular system from the images remains a challenging topic. The work presented in this thesis describes the development of segmentation and motion analysis techniques for the study of the cardiac anatomy and function in cardiac magnetic resonance (CMR) images. The first main contribution of the thesis is the development of a fully automatic cardiac segmentation technique that integrates and combines a series of state-of-the-art techniques. The proposed segmentation technique is capable of generating an accurate 3D segmentation from multiple image sequences. The proposed segmentation technique is robust even in the presence of pathological changes, large anatomical shape variations and locally varying contrast in the images. Another main contribution of this thesis is the development of motion tracking techniques that can integrate motion information from different sources. For example, the radial motion of the myocardium can be tracked easily in untagged MR imaging since the epi- and endocardial surfaces are clearly visible. On the other hand, tagged MR imaging allows easy tracking of both longitudinal and circumferential motion. We propose a novel technique based on non-rigid image registration for the myocardial motion estimation using both untagged and 3D tagged MR images. The novel aspect of our technique is its simultaneous use of complementary information from both untagged and 3D tagged MR imaging. The similarity measure is spatially weighted to maximise the utility of information from both images. The thesis also proposes a sparse representation for free-form deformations (FFDs) using the principles of compressed sensing. The sparse free-form deformation (SFFD) model can capture fine local details such as motion discontinuities without sacrificing robustness. We demonstrate the capabilities of the proposed framework to accurately estimate smooth as well as discontinuous deformations in 2D and 3D CMR image sequences. Compared to the standard FFD approach, a significant increase in registration accuracy can be observed in datasets with discontinuous motion patterns. Both the segmentation and motion tracking techniques presented in this thesis have been applied to clinical studies. We focus on two important clinical applications that can be addressed by the techniques proposed in this thesis. The first clinical application aims at measuring longitudinal changes in cardiac morphology and function during the cardiac remodelling process. The second clinical application aims at selecting patients that positively respond to cardiac resynchronization therapy (CRT). The final chapter of this thesis summarises the main conclusions that can be drawn from the work presented here and also discusses possible avenues for future research

    Quantification in cardiac MRI: advances in image acquisition and processing

    Get PDF
    Cardiac magnetic resonance (CMR) imaging enables accurate and reproducible quantification of measurements of global and regional ventricular function, blood flow, perfusion at rest and stress as well as myocardial injury. Recent advances in MR hardware and software have resulted in significant improvements in image quality and a reduction in imaging time. Methods for automated and robust assessment of the parameters of cardiac function, blood flow and morphology are being developed. This article reviews the recent advances in image acquisition and quantitative image analysis in CMR
    corecore