785 research outputs found
Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine
<p>Abstract</p> <p>Background</p> <p>Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis.</p> <p>Methods</p> <p>rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components.</p> <p>Results</p> <p>rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology.</p> <p>Conclusions</p> <p>Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media.</p
A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced) and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms
PURPOSE: To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION: Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. METHODS: Forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuroradiologists rated the time-of-flight-magnetic resonance angiography, the contrast-enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. RESULTS: Inter-observer agreement was excellent for both methods (K = 0.93; 95 % CI: 0.84-1). Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 % CI: 0.93-1) and between time-of-flight-magnetic resonance angiography and contrast-enhanced-magnetic resonance angiography (K = 0.98; 95% CI: 0.93-1). Disagreement occurred in only one case (2.3%), which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between contrast-enhanced-magnetic resonance angiography and digital subtraction angiography was perfect (K = 1; 95% CI: 1-1). In three patients, in-stent stenosis was identified by magnetic resonance angiography but not confirmed by digital subtraction angiography. CONCLUSION: Digital subtraction angiography and both 3T magnetic resonance angiography techniques have excellent reproducibility for the assessment of aneurysms embolized exclusively with coils. In those cases also treated with stent remodeling, digital subtraction angiography may still be necessary to confirm eventual parent artery stenosis, as identified by magnetic resonance angiography
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
Application of postmortem imaging modalities in cases of sudden death due to cardiovascular diseases-current achievements and limitations from a pathology perspective : Endorsed by the Association for European Cardiovascular Pathology and by the International Society of Forensic Radiology and Imaging.
Postmortem imaging (PMI) is increasingly used in postmortem practice and is considered a potential alternative to a conventional autopsy, particularly in case of sudden cardiac deaths (SCD). In 2017, the Association for European Cardiovascular Pathology (AECVP) published guidelines on how to perform an autopsy in such cases, which is still considered the gold standard, but the diagnostic value of PMI herein was not analyzed in detail. At present, significant progress has been made in the PMI diagnosis of acute ischemic heart disease, the most important cause of SCD, while the introduction of postmortem CT angiography (PMCTA) has improved the visualization of several parameters of coronary artery pathology that can support a diagnosis of SCD. Postmortem magnetic resonance (PMMR) allows the detection of acute myocardial injury-related edema. However, PMI has limitations when compared to clinical imaging, which severely impacts the postmortem diagnosis of myocardial injuries (ischemic versus non-ischemic), the age-dating of coronary occlusion (acute versus old), other potentially SCD-related cardiac lesions (e.g., the distinctive morphologies of cardiomyopathies), aortic diseases underlying dissection or rupture, or pulmonary embolism. In these instances, PMI cannot replace a histopathological examination for a final diagnosis. Emerging minimally invasive techniques at PMI such as image-guided biopsies of the myocardium or the aorta, provide promising results that warrant further investigations. The rapid developments in the field of postmortem imaging imply that the diagnosis of sudden death due to cardiovascular diseases will soon require detailed knowledge of both postmortem radiology and of pathology
Automatic Spatiotemporal Analysis of Cardiac Image Series
RĂSUMĂ
Ă ce jour, les maladies cardiovasculaires demeurent au premier rang des principales causes de
dĂ©cĂšs en AmĂ©rique du Nord. Chez lâadulte et au sein de populations de plus en plus jeunes,
la soi-disant Ă©pidĂ©mie dâobĂ©sitĂ© entraĂźnĂ©e par certaines habitudes de vie tels que la mauvaise
alimentation, le manque dâexercice et le tabagisme est lourde de consĂ©quences pour les personnes
affectées, mais aussi sur le systÚme de santé. La principale cause de morbidité et de
mortalitĂ© chez ces patients est lâathĂ©rosclĂ©rose, une accumulation de plaque Ă lâintĂ©rieur des
vaisseaux sanguins à hautes pressions telles que les artÚres coronaires. Les lésions athérosclérotiques
peuvent entraĂźner lâischĂ©mie en bloquant la circulation sanguine et/ou en provoquant
une thrombose. Cela mĂšne souvent Ă de graves consĂ©quences telles quâun infarctus. Outre les
problÚmes liés à la sténose, les parois artérielles des régions criblées de plaque augmentent la
rigidité des parois vasculaires, ce qui peut aggraver la condition du patient. Dans la population
pédiatrique, la pathologie cardiovasculaire acquise la plus fréquente est la maladie de
Kawasaki. Il sâagit dâune vasculite aigĂŒe pouvant affecter lâintĂ©gritĂ© structurale des parois des
artĂšres coronaires et mener Ă la formation dâanĂ©vrismes. Dans certains cas, ceux-ci entravent
lâhĂ©modynamie artĂ©rielle en engendrant une perfusion myocardique insuffisante et en activant
la formation de thromboses.
Le diagnostic de ces deux maladies coronariennes sont traditionnellement effectuĂ©s Ă lâaide
dâangiographies par fluoroscopie. Pendant ces examens paracliniques, plusieurs centaines de
projections radiographiques sont acquises en sĂ©ries suite Ă lâinfusion artĂ©rielle dâun agent de
contraste. Ces images révÚlent la lumiÚre des vaisseaux sanguins et la présence de lésions
potentiellement pathologiques, sâil y a lieu. Parce que les sĂ©ries acquises contiennent de lâinformation
trĂšs dynamique en termes de mouvement du patient volontaire et involontaire (ex.
battements cardiaques, respiration et dĂ©placement dâorganes), le clinicien base gĂ©nĂ©ralement
son interprĂ©tation sur une seule image angiographique oĂč des mesures gĂ©omĂ©triques sont effectuĂ©es
manuellement ou semi-automatiquement par un technicien en radiologie. Bien que
lâangiographie par fluoroscopie soit frĂ©quemment utilisĂ© partout dans le monde et souvent
considĂ©rĂ© comme lâoutil de diagnostic âgold-standardâ pour de nombreuses maladies vasculaires,
la nature bidimensionnelle de cette modalitĂ© dâimagerie est malheureusement trĂšs
limitante en termes de spécification géométrique des différentes régions pathologiques. En effet,
la structure tridimensionnelle des stĂ©noses et des anĂ©vrismes ne peut pas ĂȘtre pleinement
appréciée en 2D car les caractéristiques observées varient selon la configuration angulaire de
lâimageur. De plus, la prĂ©sence de lĂ©sions affectant les artĂšres coronaires peut ne pas reflĂ©ter
la véritable santé du myocarde, car des mécanismes compensatoires naturels (ex. vaisseaux----------ABSTRACT
Cardiovascular disease continues to be the leading cause of death in North America. In adult
and, alarmingly, ever younger populations, the so-called obesity epidemic largely driven by
lifestyle factors that include poor diet, lack of exercise and smoking, incurs enormous stresses
on the healthcare system. The primary cause of serious morbidity and mortality for these
patients is atherosclerosis, the build up of plaque inside high pressure vessels like the coronary
arteries. These lesions can lead to ischemic disease and may progress to precarious blood
flow blockage or thrombosis, often with infarction or other severe consequences. Besides
the stenosis-related outcomes, the arterial walls of plaque-ridden regions manifest increased
stiffness, which may exacerbate negative patient prognosis. In pediatric populations, the
most prevalent acquired cardiovascular pathology is Kawasaki disease. This acute vasculitis
may affect the structural integrity of coronary artery walls and progress to aneurysmal lesions.
These can hinder the blood flowâs hemodynamics, leading to inadequate downstream
perfusion, and may activate thrombus formation which may lead to precarious prognosis.
Diagnosing these two prominent coronary artery diseases is traditionally performed using
fluoroscopic angiography. Several hundred serial x-ray projections are acquired during selective
arterial infusion of a radiodense contrast agent, which reveals the vesselsâ luminal
area and possible pathological lesions. The acquired series contain highly dynamic information
on voluntary and involuntary patient movement: respiration, organ displacement and
heartbeat, for example. Current clinical analysis is largely limited to a single angiographic
image where geometrical measures will be performed manually or semi-automatically by a
radiological technician. Although widely used around the world and generally considered
the gold-standard diagnosis tool for many vascular diseases, the two-dimensional nature of
this imaging modality is limiting in terms of specifying the geometry of various pathological
regions. Indeed, the 3D structures of stenotic or aneurysmal lesions may not be fully appreciated
in 2D because their observable features are dependent on the angular configuration of
the imaging gantry. Furthermore, the presence of lesions in the coronary arteries may not
reflect the true health of the myocardium, as natural compensatory mechanisms may obviate
the need for further intervention. In light of this, cardiac magnetic resonance perfusion
imaging is increasingly gaining attention and clinical implementation, as it offers a direct
assessment of myocardial tissue viability following infarction or suspected coronary artery
disease. This type of modality is plagued, however, by motion similar to that present in fluoroscopic
imaging. This issue predisposes clinicians to laborious manual intervention in order
to align anatomical structures in sequential perfusion frames, thus hindering automation o
- âŠ