1,714 research outputs found

    Objective Evaluation Criteria for Shooting Quality of Stereo Cameras over Short Distance

    Get PDF
    Stereo cameras are the basic tools used to obtain stereoscopic image pairs, which can lead to truly great image quality. However, some inappropriate shooting conditions may cause discomfort while viewing stereo images. It is therefore considerably necessary to establish the perceptual criteria that can be used to evaluate the shooting quality of stereo cameras. This article proposes objective quality evaluation criteria based on the characteristics of parallel and toed-in camera configurations. Considering the different internal structures and basic shooting principles, this paper focuses on short-distance shooting conditions and establishes assessment criteria for both parallel and toed-in camera configurations. Experimental results show that the proposed evaluation criteria can predict the visual perception of stereoscopic images and effectively evaluate stereoscopic image quality

    Morphing a Stereogram into Hologram

    Full text link
    This paper develops a simple and fast method to reconstruct reality from stereoscopic images. We bring together ideas from robust optical flow techniques, morphing deformations and lightfield 3D rendering in order to create unsupervised multiview images of a scene. The reconstruction algorithm provides a good visualization of the virtual 3D imagery behind stereograms upon display on a headset-free Looking Glass 3D monitor. We discuss the possibility of applying the method for live 3D streaming optimized via an associated lookup table.Comment: PDF, 8 pages, 4 Fig

    Wavelet based stereo images reconstruction using depth images

    Get PDF
    It is believed by many that three-dimensional (3D) television will be the next logical development toward a more natural and vivid home entertaiment experience. While classical 3D approach requires the transmission of two video streams, one for each view, 3D TV systems based on depth image rendering (DIBR) require a single stream of monoscopic images and a second stream of associated images usually termed depth images or depth maps, that contain per-pixel depth information. Depth map is a two-dimensional function that contains information about distance from camera to a certain point of the object as a function of the image coordinates. By using this depth information and the original image it is possible to reconstruct a virtual image of a nearby viewpoint by projecting the pixels of available image to their locations in 3D space and finding their position in the desired view plane. One of the most significant advantages of the DIBR is that depth maps can be coded more efficiently than two streams corresponding to left and right view of the scene, thereby reducing the bandwidth required for transmission, which makes it possible to reuse existing transmission channels for the transmission of 3D TV. This technique can also be applied for other 3D technologies such as multimedia systems. In this paper we propose an advanced wavelet domain scheme for the reconstruction of stereoscopic images, which solves some of the shortcommings of the existing methods discussed above. We perform the wavelet transform of both the luminance and depth images in order to obtain significant geometric features, which enable more sensible reconstruction of the virtual view. Motion estimation employed in our approach uses Markov random field smoothness prior for regularization of the estimated motion field. The evaluation of the proposed reconstruction method is done on two video sequences which are typically used for comparison of stereo reconstruction algorithms. The results demonstrate advantages of the proposed approach with respect to the state-of-the-art methods, in terms of both objective and subjective performance measures

    Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions

    A Virtual Testbed for Fish-Tank Virtual Reality: Improving Calibration with a Virtual-in-Virtual Display

    Get PDF
    With the development of novel calibration techniques for multimedia projectors and curved projection surfaces, volumetric 3D displays are becoming easier and more affordable to build. The basic requirements include a display shape that defines the volume (e.g. a sphere, cylinder, or cuboid) and a tracking system to provide each user's location for the perspective corrected rendering. When coupled with modern graphics cards, these displays are capable of high resolution, low latency, high frame rate, and even stereoscopic rendering; however, like many previous studies have shown, every component must be precisely calibrated for a compelling 3D effect. While human perceptual requirements have been extensively studied for head-tracked displays, most studies featured seated users in front of a flat display. It remains unclear if results from these flat display studies are applicable to newer, walk-around displays with enclosed or curved shapes. To investigate these issues, we developed a virtual testbed for volumetric head-tracked displays that can measure calibration accuracy of the entire system in real-time. We used this testbed to investigate visual distortions of prototype curved displays, improve existing calibration techniques, study the importance of stereo to performance and perception, and validate perceptual calibration with novice users. Our experiments show that stereo is important for task performance, but requires more accurate calibration, and that novice users can make effective use of perceptual calibration tools. We also propose a novel, real-time calibration method that can be used to fine-tune an existing calibration using perceptual feedback. The findings from this work can be used to build better head-tracked volumetric displays with an unprecedented amount of 3D realism and intuitive calibration tools for novice users

    Automatic 3DS Conversion of Historical Aerial Photographs

    Get PDF
    In this paper we present a method for the generation of 3D stereo (3DS) pairs from sequences of historical aerial photographs. The goal of our work is to provide a stereoscopic display when the existing exposures are in a monocular sequence. Each input image is processed using its neighbours and a synthetic image is rendered, which, together with the original one, form a stereo pair. Promising results on real images taken from a historical photo archive are shown, that corroborate the viability of generating 3DS data from monocular footage

    An automated calibration method for non-see-through head mounted displays

    Get PDF
    Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical see-through HMDs. Building on our existing approach to HMD calibration Gilson et al. (2008), we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside a HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in multiple positions. The centroids of the markers on the calibration object are recovered and their locations re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the HMD display's intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors without the need for error-prone human judgements
    • …
    corecore