39,900 research outputs found

    Static and dynamic accuracy of an innovative miniaturized wearable platform for short range distance measurements for human movement applications

    Get PDF
    Magneto-inertial measurement units (MIMU) are a suitable solution to assess human motor performance both indoors and outdoors. However, relevant quantities such as step width and base of support, which play an important role in gait stability, cannot be directly measured using MIMU alone. To overcome this limitation, we developed a wearable platform specifically designed for human movement analysis applications, which integrates a MIMU and an Infrared Time-of-Flight proximity sensor (IR-ToF), allowing for the estimate of inter-object distance. We proposed a thorough testing protocol for evaluating the IR-ToF sensor performances under experimental conditions resembling those encountered during gait. In particular, we tested the sensor performance for different (i) target colors; (ii) sensor-target distances (up to 200 mm) and (iii) sensor-target angles of incidence (AoI) (up to 60°). Both static and dynamic conditions were analyzed. A pendulum, simulating the oscillation of a human leg, was used to generate highly repeatable oscillations with a maximum angular velocity of 6 rad/s. Results showed that the IR-ToF proximity sensor was not sensitive to variations of both distance and target color (except for black). Conversely, a relationship between error magnitude and AoI values was found. For AoI equal to 0°, the IR-ToF sensor performed equally well both in static and dynamic acquisitions with a distance mean absolute error <1.5 mm. Errors increased up to 3.6 mm (static) and 11.9 mm (dynamic) for AoI equal to ±30°, and up to 7.8 mm (static) and 25.6 mm (dynamic) for AoI equal to ±60°. In addition, the wearable platform was used during a preliminary experiment for the estimation of the inter-foot distance on a single healthy subject while walking. In conclusion, the combination of magneto-inertial unit and IR-ToF technology represents a valuable alternative solution in terms of accuracy, sampling frequency, dimension and power consumption, compared to existing technologies

    Real-time human ambulation, activity, and physiological monitoring:taxonomy of issues, techniques, applications, challenges and limitations

    Get PDF
    Automated methods of real-time, unobtrusive, human ambulation, activity, and wellness monitoring and data analysis using various algorithmic techniques have been subjects of intense research. The general aim is to devise effective means of addressing the demands of assisted living, rehabilitation, and clinical observation and assessment through sensor-based monitoring. The research studies have resulted in a large amount of literature. This paper presents a holistic articulation of the research studies and offers comprehensive insights along four main axes: distribution of existing studies; monitoring device framework and sensor types; data collection, processing and analysis; and applications, limitations and challenges. The aim is to present a systematic and most complete study of literature in the area in order to identify research gaps and prioritize future research directions

    The Relationship between Force Platform Measures and Total Body Center of Mass

    Get PDF
    The ability of a person to maintain stable posture is essential for activities of daily living. Research in this field has evolved to include sensitive assessment technology including force platforms and 3-dimensional kinematic motion analysis systems. Although many studies have investigated postural stability under the auspice of posturography and the use of force platforms, relatively few have incorporated kinematic motion analysis techniques. Furthermore, of the studies that have utilized a multivariate research model, none have sought to identify the relationship between force platform measures including both the variation of movement of the x- and y-coordinates of the center of pressure (COP), and the 3-dimensional coordinates of the total body center of mass (COM). This study used a descriptive design to evaluate the relationship between force platform measures and the kinematic measures dealing with the total body COM in 14 healthy participants (height = 1.70 ± 0.09 m, mass = 67.7 ± 9.9 kg; age = 24.9 ± 3.8 yrs). Intraclass correlations (ICC) and standard error of measurements (SEM) were determined for common variables of interest used in standard posturography models. The results suggest that the variation of the excursion of the COP coordinates best represent the variation of the total body COM in the x- and y-directions. There was a force platform measure that correlated significantly with the vertical component of total body COM in only 3 of the 8 conditions. The ICC values obtained when analyzing individual conditions revealed that the variation in the force measurements were much more reliable than those representing the variation in movement of the COP, suggesting a need for the development of higher order methods of modeling 3-dimensional COM information from force platforms
    • 

    corecore