    Modeling and Experimental Verification of Adaptive 100% Stator Ground Fault Protection Schemes for Synchronous Generators

    Get PDF
    Salient pole synchronous generators as the main component of an electricity generation station should be carefully maintained and their operation has to be monitored such that any damage on them is avoided. Otherwise, the generating station might experience frequent shut downs which results in electricity generation interruptions and high costs associated with repairing and compensation of lack of energy. In this sense, many protective schemes focusing on a variety of synchronous generator faults have already been proposed and are still modified and developed to further enhance the quality of protection. In this thesis, synchronous generator stator windings to ground fault is studied as one of the most common and crucial faults in these machines. Numerous methods of stator winding to ground fault protection schemes are also reported in the literature. Third harmonic differential voltage and sub-harmonic schemes are studied in this research. A novel adaptive scheme for both methods is modelled and implemented in a comprehensive lab scale set-up where a real generation unit is scaled down including all different components and apparatus. The simulation model is also established based on simultaneous finite element analysis (FEA) and coupled magnetic circuit to assist with system configuration design and parameter selections. The adaptive scheme is proved to be capable of detecting stator windings to ground faults based on actual experimental data. Finally, the proposed adaptive scheme is compared against other available non-adaptive protection schemes currently used in industrial relays. Several important performance evaluation criteria in protection schemes such as sensitivity and security of operation referred to as reliability are considered. It is shown that the adaptive scheme offers higher reliability than other schemes which emphasizes its credibility and applicability

    Annual Report, 2014-2015

    Get PDF

    IEEE Trans Ind Appl

    Get PDF
    The underground-mining environment can affect radio-signal propagation in various ways. Understanding these effects is especially critical in evaluating communications systems used during normal mining operations and during mine emergencies. One of these types of communications systems relies on medium-frequency (MF) radio frequencies. This paper presents the simulation and measurement results of recent National Institute for Occupational Safety and Health (NIOSH) research aimed at investigating MF coupling between a transmission line (TL) and a loop antenna in an underground coal mine. Two different types of measurements were completed: 1) line-current distribution and 2) line-to-antenna coupling. Measurements were taken underground in an experimental coal mine and on a specially designed surface test area. The results of these tests are characterized by current along a TL and voltage induced in the loop from a line. This paper concludes with a discussion of issues for MF TLs. These include electromagnetic fields at the ends of the TL, connection of the ends of the TL, the effect of other conductors underground, and the proximity of coal or earth. These results could help operators by providing examples of these challenges that may be experienced underground and a method by which to measure voltage induced by a line.CC999999/Intramural CDC HHS/United States2016-10-24T00:00:00Z27784954PMC5076858vault:1986

    Power source electronic ballast for electrodeless fluorescent lamps

    Get PDF
    This paper presents the design, control strategy and experimental results of a two-step, power factor correction stage (PFC) and resonant inverter (RI), electronic ballast proposal to supply 150 W electrodeless fluorescent lamps (EFL). The PFC acts as a controlled power source and provides mid and long-term stability to the system, while the stability of the current through the lamp is achieved with the RI. In addition, the power-mode control requires limitation of the output voltage. The dual operation mode of the PFC (voltage source mode and power source mode) enables an e cient soft resonant ignition and the implementation of simple dimming regulation.This work has been supported by the Spanish Ministry of Science and Innovation and the EU through the projects CICYT-FEDER-TEC2014-52316-R: “Estimation and Optimal Control for Energy Conversion with Digital Devices, ECOTRENDD” and RTI2018-095138-B-C31 PEGIA: “Power Electronics for the Grid and Industry Applications”

    Annual Report, 2017-2018

    Get PDF

    A Coordinated Control Approach for DC link and Rotor Crowbars to Improve Fault Ride-Through of DFIG-Based Wind Turbine

    Get PDF
    Nowadays, most double fed induction generators (DFIGs)-based wind turbines are equipped with a rotor crowbar connected in parallel with the rotor side converter (RSC). The parallel rotor side crowbar (PRSC) is used to protect the RSC and dc-link capacitor by dissipating the rotor energy during grid fault condition. In this paper, two types of crowbar protections are used, one in the rotor winding and the second in the dc link. During the fault condition, the rotor winding crowbar connects in series with the rotor winding and RSC to decrease the RSC current and dissipate the rotor energy. The general PRSC does not have the ability to significantly decrease the over-current. To protect the semiconductor switches of RSC, DFIG should not be kept connected with the utility grids under severe faults. The dc-link capacitor crowbar (DCCC) operates only if the dc capacitor voltage exceeds a threshold level. Both the series rotor side crowbar (SRSC) and the DCCC operate in coordination with each other to protect RSC and dc link during fault condition, and improve the fault ride through of the DFIG. Using the proposed SRSC, RSC continues its operation to control the DFIG during fault condition. Thereby, the reactive power can be injected to support the voltage at the point of common coupling. The behavior of the DFIG is investigated when the combined crowbars are operating with the proposed coordinated control approach and results are presented

    Air Force Institute of Technology Research Report 2018

    Get PDF
    This Research Report presents the FY18 research statistics and contributions of the Graduate School of Engineering and Management (EN) at AFIT. AFIT research interests and faculty expertise cover a broad spectrum of technical areas related to USAF needs, as reflected by the range of topics addressed in the faculty and student publications listed in this report. In most cases, the research work reported herein is directly sponsored by one or more USAF or DOD agencies. AFIT welcomes the opportunity to conduct research on additional topics of interest to the USAF, DOD, and other federal organizations when adequate manpower and financial resources are available and/or provided by a sponsor. In addition, AFIT provides research collaboration and technology transfer benefits to the public through Cooperative Research and Development Agreements (CRADAs). Interested individuals may discuss ideas for new research collaborations, potential CRADAs, or research proposals with individual faculty using the contact information in this document

    A mapping study on documentation in Continuous Software Development

    Get PDF
    Context: With an increase in Agile, Lean, and DevOps software methodologies over the last years (collectively referred to as Continuous Software Development (CSD)), we have observed that documentation is often poor. Objective: This work aims at collecting studies on documentation challenges, documentation practices, and tools that can support documentation in CSD. Method: A systematic mapping study was conducted to identify and analyze research on documentation in CSD, covering publications between 2001 and 2019. Results: A total of 63 studies were selected. We found 40 studies related to documentation practices and challenges, and 23 studies related to tools used in CSD. The challenges include: informal documentation is hard to understand, documentation is considered as waste, productivity is measured by working software only, documentation is out-of-sync with the software and there is a short-term focus. The practices include: non-written and informal communication, the usage of development artifacts for documentation, and the use of architecture frameworks. We also made an inventory of numerous tools that can be used for documentation purposes in CSD. Overall, we recommend the usage of executable documentation, modern tools and technologies to retrieve information and transform it into documentation, and the practice of minimal documentation upfront combined with detailed design for knowledge transfer afterwards. Conclusion: It is of paramount importance to increase the quantity and quality of documentation in CSD. While this remains challenging, practitioners will benefit from applying the identified practices and tools in order to mitigate the stated challenges
    • …