3,711 research outputs found
Ultrasound shear wave elastography for liver disease. A critical appraisal of the many actors on the stage
In the last 12\u200a-\u200a18 months nearly all ultrasound manufacturers have arrived to implement ultrasound shear wave elastography modality in their equipment for the assessment of chronic liver disease; the few remaining players are expected to follow in 2016.When all manufacturers rush to a new technology at the same time, it is evident that the clinical demand for this information is of utmost value. Around 1990, there was similar demand for color Doppler ultrasound; high demand for contrast-enhanced ultrasonography was evident at the beginning of this century, and around 2010 demand increased for strain elastography. However, some issues regarding the new shear wave ultrasound technologies must be noted to avoid misuse of the resulting information for clinical decisions. As new articles are expected to appear in 2016 reporting the findings of the new technologies from various companies, we felt that the beginning of this year was the right time to present an appraisal of these issues. We likewise expect that in the meantime EFSUMB will release a new update of the existing guidelines 1 2.The first ultrasound elastography method became available 13 years ago in the form of transient elastography with Fibroscan(\uae) 3. It was the first technique providing non-invasive quantitive information about the stiffness of the liver and hence regarding the amount of fibrosis in chronic liver disease 3. The innovation was enormous, since a non-invasive modality was finally available to provide findings otherwise achievable only by liver biopsy. In fact, prior to ultrasound elastography, a combination of conventional and Doppler ultrasound parameters were utilized to inform the physician about the presence of cirrhosis and portal hypertension 4. However, skilled operators were required, reproducibility and diagnostic accuracy were suboptimal, and it was not possible to differentiate the pre-cirrhotic stages of fibrosis. All these limitations were substantially improved by transient elastography, performed with Fibroscan(\uae), a technology dedicated exclusively to liver elastography. Since then, more than 1300 articles dealing with transient elastography have been listed in PubMed, some describing results with more than 10,000 patients 5. The technique has been tested in nearly all liver disease etiologies, with histology as the reference standard. Meta-analysis of data, available in many etiologies 6, showed good performance and reproducibility as well as some situations limiting reliability 5. Thresholds for the different fibrosis stages (F0 to F4) have been provided by many large-scale studies utilizing histology as the reference standard 7. Transient elastography tracks the velocity of shear waves generated by the gentle hit of a piston on the skin, with the resulting compression wave traveling in the liver along its longitudinal axis. The measurement is made in a 4\u200acm long section of the liver, thus able to average slightly inhomogeneous fibrotic deposition.In 2008 a new modality became available, Acoustic Radiation Force Impulse (ARFI) quantification, and classified by EFSUMB 1 as point shear wave elastography (pSWE), since the speed of the shear wave (perpendicular to the longitudinal axis) is measured in a small region (a "point", few millimeters) at a freely-choosen depth within 8\u200acm from the skin. This technology was the first to be implemented in a conventional ultrasound scanner by Siemens(\uae) 8. Several articles have been published regarding this technology, most with the best reference standards 9, some including findings on more than 1000 hepatitis C patients 10 or reporting meta-analysis of data 11. Although the correlation between Siemens pSWE and transient elastography appeared high 12 13, the calculated thresholds for the different fibrosis stages and the stiffness ranges between the two techniques are not superimposable.Interestingly, pSWE appears to provide greater applicability than transient elastography for measuring both liver 13 and spleen stiffness, which is a new application of elastography 14, of interest for the prediction of the degree of portal hypertension 15 16.Nowadays other companies have started producing equipment with pSWE technology, but only very few articles have been published so far, for instance describing the use of Philips(\uae) equipment, which was the second to provide pSWE. These articles show preliminary good results also in comparison with TE 17 18. Not enough evidence is currently available in the literature about the elastographic performance of the products most recently introduced to the market. Furthermore, with some products the shear wave velocities generated by a single ultrasound acoustic push pulse can be measured in a bidimensional area (a box in the range of 2\u200a-\u200a3\u200acm per side) rather than in a single small point, producing a so-called bidimensional 2D-SWE 1. The stiffness is depicted in color within the area and refreshing of the measurement occurs every 1\u200a-\u200a2 seconds. Once the best image is acquired, the operator chooses a Region Of Interest (ROI) within the color box, where the mean stiffness is then calculated. 2D-SWE can be performed as a "one shot" technique or as a semi-"real-time" technique for a few seconds (at about 1 frame per second) in order to obtain a stable elastogram. With either technique, there should be no motion/breathing during image acquisition. A bidimensional averaged area should overcome the limitation of pSWE to inadvertently investigate small regions of greater or lesser stiffness than average. A shear wave quality indicator could be useful to provide real-time feedback and optimize placement of the sampling ROIs, a technology recently presented by Toshiba(\uae), but which is still awaiting validation in the literature.Supersonic Imagine by Aixplorer(\uae) which works with a different modality of insonation and video analysis compared to the the previously-mentioned three techniques (i.\u200ae., transient elastography, pSWE and 2D-SWE), leading to a bidimensional assessment of liver stiffness in real time up to 5\u200aHz and in larger regions; thus this technique is also termed real-time 2\u200aD SWE. It has been available on the market for a few years 19 20, and many articles have been published showing stiffness values quite similar to those of Fibroscan(\uae) 21; likewise, defined thresholds based on histological findings have appeared in several articles 19 20 21.After this brief summary of the technological state of the art we would like to mention the following critical issues that we believe every user should note prior to providing liver stiffness reports. \ub7 The thresholds obtained from the "oldest" techniques for the various fibrosis stages based on hundreds of patients with histology as reference standard cannot be straightforwardly applied to the new ultrasound elastography techniques, even if based on the same principle (e.\u200ag. pSWE). In fact, the different manufacturers apply proprietary patented calculation modes, which might result in slightly to moderately different values. It should be kept in mind that the range for intermediate fibrosis stages (F1 to F3) is quite narrow, in the order of 2\u200a-\u200a3 kilopascal (over a total range spanning 2 to 75 kPa with Fibroscan), so that slightly different differences in outputs could shift the assessment of patients from one stage to another. Comparative studies using phantoms and healthy volunteers, as well as patients, are eagerly awaited. In fact, the equipment might not produce linear correlations of measurements at different degrees of severity of fibrosis. As a theoretical example, some equipment might well correlate in their values with an older technique, such as transient elastography, at low levels of liver fibrosis, but not as well in cases of more advanced fibrosis or vice versa. Consequentely, when elastography data are included in a report, the equipment utilized for the measurement should be clearly specified, and conclusions about the fibrosis stage should be withheld if an insufficient number of comparative studies with solid reference standards are available for that specific equipment.. \ub7 Future studies using histology as a reference might be biased in comparison to previous studies, since nowadays fewer patients with chronic hepatitis C or hepatitis B undergo biopsy. In fact, due to wide availability of effective drugs as well as the use of established elastography methods for patients with viral hepatitis, most cases submitted to biopsy today have uncertain etiology or inconsistent and inconclusive clinical data. Therefore, extrapolated thresholds from such inhomogeneous populations applied to more ordinary patients with viral hepatitis might become problematic in the future, although no better solution is currently anticipated. This situation might lead to the adoption of a standard validated elastographic method as reference, but this has to be agreed-upon at an international level.. \ub7 Ultrasound elastography embedded in conventional scanners usually allows the choice of where to place the ROI within the color stiffness box and whether to confirm or exclude each single measurement when determining the final value. Thus, the operator has a greater potential to influence the final findings than with Fibroscan\uae, where these choices are not available. This has to be kept in mind to avoid the possibility that an operator could, even inadvertently, tend to confirm an assumption about that specific patient or to confirm the patient's expectations.. \ub7 Quality criteria for the new technologies following transient elastography are absent (depending on the manufacturer) or have not been satisfactorily defined, so that the information potentially inserted in a report cannot currently be judged for its reliability by the clinician.. (ABSTRACT TRUNCATED
Hepatic steatosis and fibrosis: Non-invasive assessment
Chronic liver disease is a major cause of morbidity and mortality worldwide and usually develops over many years, as a result of chronic inflammation and scarring, resulting in end-stage liver disease and its complications. The progression of disease is characterised by ongoing inflammation and consequent fibrosis, although hepatic steatosis is increasingly being recognised as an important pathological feature of disease, rather than being simply an innocent bystander. However, the current gold standard method of quantifying and staging liver disease, histological analysis by liver biopsy, has several limitations and can have associated morbidity and even mortality. Therefore, there is a clear need for safe and noninvasive assessment modalities to determine hepatic steatosis, inflammation and fibrosis. This review covers key mechanisms and the importance of fibrosis and steatosis in the progression of liver disease. We address non-invasive imaging and blood biomarker assessments that can be used as an alternative to information gained on liver biopsy
Diagnostic value of two dimensional shear wave elastography combined with texture analysis in early liver fibrosis.
BACKGROUND: Staging diagnosis of liver fibrosis is a prerequisite for timely diagnosis and therapy in patients with chronic hepatitis B. In recent years, ultrasound elastography has become an important method for clinical noninvasive assessment of liver fibrosis stage, but its diagnostic value for early liver fibrosis still needs to be further improved. In this study, the texture analysis was carried out on the basis of two dimensional shear wave elastography (2D-SWE), and the feasibility of 2D-SWE plus texture analysis in the diagnosis of early liver fibrosis was discussed.
AIM: To assess the diagnostic value of 2D-SWE combined with textural analysis in liver fibrosis staging.
METHODS: This study recruited 46 patients with chronic hepatitis B. Patients underwent 2D-SWE and texture analysis; Young\u27s modulus values and textural patterns were obtained, respectively. Textural pattern was analyzed with regard to contrast, correlation, angular second moment (ASM), and homogeneity. Pathological results of biopsy specimens were the gold standard; comparison and assessment of the diagnosis efficiency were conducted for 2D-SWE, texture analysis and their combination.
RESULTS: 2D-SWE displayed diagnosis efficiency in early fibrosis, significant fibrosis, severe fibrosis, and early cirrhosis (AUC \u3e 0.7, P \u3c 0.05) with respective AUC values of 0.823 (0.678-0.921), 0.808 (0.662-0.911), 0.920 (0.798-0.980), and 0.855 (0.716-0.943). Contrast and homogeneity displayed independent diagnosis efficiency in liver fibrosis stage (AUC \u3e 0.7, P \u3c 0.05), whereas correlation and ASM showed limited values. AUC of contrast and homogeneity were respectively 0.906 (0.779-0.973), 0.835 (0.693-0.930), 0.807 (0.660-0.910) and 0.925 (0.805-0.983), 0.789 (0.639-0.897), 0.736 (0.582-0.858), 0.705 (0.549-0.883) and 0.798 (0.650-0.904) in four liver fibrosis stages, which exhibited equivalence to 2D-SWE in diagnostic efficiency (P \u3e 0.05). Combined diagnosis (PRE) displayed diagnostic efficiency (AUC \u3e 0.7, P \u3c 0.01) for all fibrosis stages with respective AUC of 0.952 (0.841-0.994), 0.896 (0.766-0.967), 0.978 (0.881-0.999), 0.947 (0.835-0.992). The combined diagnosis showed higher diagnosis efficiency over 2D-SWE in early liver fibrosis (P \u3c 0.05), whereas no significant differences were observed in other comparisons (P \u3e 0.05).
CONCLUSION: Texture analysis was capable of diagnosing liver fibrosis stage, combined diagnosis had obvious advantages in early liver fibrosis, liver fibrosis stage might be related to the hepatic tissue hardness distribution
Serum proteome profiling identifies novel and powerful markers of cystic fibrosis liver disease.
Cystic Fibrosis associated liver disease (CFLD) develops in approximately 30% of CF patients. However, routine sensitive diagnostic tools for CFLD are lacking. Within this study, we aimed to identify new experimental biomarkers for the detection of CFLD.
45 CF patients were included in the study and received transient elastography. Differential regulation of 220 different serum proteins was assessed in a subgroup of patients with and without CFLD. Most interesting candidate proteins were further quantified and validated by ELISA in the whole patient cohort. To assess a potential relation of biomarker expression to the degree of hepatic fibrosis, serum biomarkers were further determined in 18 HCV patients where liver histology was available.
43 serum proteins differed at least 2-fold in patients with CFLD compared to those without liver disease as identified in proteome profiling. In ELISA quantifications, TIMP-4 and Endoglin were significantly up-regulated in patients with CFLD as diagnosed by clinical guidelines or increased liver stiffness. Pentraxin-3 was significantly decreased in patients with CFLD. Serum TIMP-4 and Endoglin showed highest values in HCV patients with liver cirrhosis compared to those with fibrosis but without cirrhosis. At a cut-off value of 6.3 kPa, transient elastography compassed a very high diagnostic accuracy and specificity for the detection of CFLD. Among the biomarkers, TIMP-4 and Endoglin exhibited a high diagnostic accuracy for CFLD. Diagnostic sensitivities and negative predictive values were increased when elastography and TIMP-4 and Endoglin were combined for the detection of CFLD.
Serum TIMP-4 and Endoglin are increased in CFLD and their expression correlates with hepatic staging. Determination of TIMP-4 and Endoglin together with transient elastography can increase the sensitivity for the non-invasive diagnosis of CFLD
Assessment of liver fibrosis and associated risk factors in HIV-infected individuals using transient elastography and serum biomarkers
Background: Liver fibrosis in human immunodeficiency virus (HIV)-infected individuals is mostly attributable to co-infection with hepatitis B or C. The impact of other risk factors, including prolonged exposure to combined antiretroviral therapy (cART) is poorly understood. Our aim was to determine the prevalence of liver fibrosis and associated risk factors in HIV-infected individuals based on non-invasive fibrosis assessment using transient elastography (TE) and serum biomarkers (Fibrotest [FT]).
Methods: In 202 consecutive HIV-infected individuals (159 men; mean age 47 ± 9 years; 35 with hepatitis-C-virus [HCV] co-infection), TE and FT were performed. Repeat TE examinations were conducted 1 and 2 years after study inclusion.
Results: Significant liver fibrosis was present in 16% and 29% of patients, respectively, when assessed by TE (≥ 7.1 kPa) and FT (> 0.48). A combination of TE and FT predicted significant fibrosis in 8% of all patients (31% in HIV/HCV co-infected and 3% in HIV mono-infected individuals). Chronic ALT, AST and γ-GT elevation was present in 29%, 20% and 51% of all cART-exposed patients and in 19%, 8% and 45.5% of HIV mono-infected individuals. Overall, factors independently associated with significant fibrosis as assessed by TE (OR, 95% CI) were co-infection with HCV (7.29, 1.95-27.34), chronic AST (6.58, 1.30-33.25) and γ-GT (5.17, 1.56-17.08) elevation and time on dideoxynucleoside therapy (1.01, 1.00-1.02). In 68 HIV mono-infected individuals who had repeat TE examinations, TE values did not differ significantly during a median follow-up time of 24 months (median intra-patient changes at last TE examination relative to baseline: -0.2 kPa, p = 0.20).
Conclusions: Chronic elevation of liver enzymes was observed in up to 45.5% of HIV mono-infected patients on cART. However, only a small subset had significant fibrosis as predicted by TE and FT. There was no evidence for fibrosis progression during follow-up TE examinations
Systematic review: the diagnosis and staging of non-alcoholic fatty liver disease and non-alcoholic steatohepatitis.
Background: Non-alcoholic fatty liver disease (NAFLD) has become the most prevalent cause of liver disease in Western countries. The development of non-alcoholic steatohepatitis (NASH) and fibrosis identifies an at-risk group with increased risk of cardiovascular and liver-related deaths. The identification and management of this at-risk group remains a clinical challenge. \ud
\ud
Aim: To perform a systematic review of the established and emerging strategies for the diagnosis and staging of NAFLD. \ud
\ud
Methods: Relevant research and review articles were identified by searching PubMed, MEDLINE and EMBASE. \ud
Results: There has been a substantial development of non-invasive risk scores, biomarker panels and radiological modalities to identify at-risk patients with NAFLD without recourse to liver biopsy on a routine basis. These modalities and algorithms have improved significantly in their diagnosis and staging of fibrosis and NASH in patients with NAFLD, and will likely impact on the number of patients undergoing liver biopsy. \ud
\ud
Conclusions: Staging for NAFLD can now be performed by a combination of radiological and laboratory techniques, greatly reducing the requirement for invasive liver biopsy
Acoustic radiation force impulse imaging for differentiation of thyroid nodules
Background: Acoustic Radiation Force Impulse (ARFI)-imaging is an ultrasound-based elastography method enabling quantitative measurement of tissue stiffness. The aim of the present study was to evaluate sensitivity and specificity of ARFI-imaging for differentiation of thyroid nodules and to compare it to the well evaluated qualitative real-time elastography (RTE).
Methods: ARFI-imaging involves the mechanical excitation of tissue using acoustic pulses to generate localized displacements resulting in shear-wave propagation which is tracked using correlation-based methods and recorded in m/s. Inclusion criteria were: nodules $5 mm, and cytological/histological assessment. All patients received conventional ultrasound, real-time elastography (RTE) and ARFI-imaging.
Results: One-hundred-fifty-eight nodules in 138 patients were available for analysis. One-hundred-thirty-seven nodules were benign on cytology/histology, and twenty-one nodules were malignant. The median velocity of ARFI-imaging in the healthy thyroid tissue, as well as in benign and malignant thyroid nodules was 1.76 m/s, 1.90 m/s, and 2.69 m/s, respectively. While no significant difference in median velocity was found between healthy thyroid tissue and benign thyroid nodules, a significant difference was found between malignant thyroid nodules on the one hand and healthy thyroid tissue (p = 0.0019) or benign thyroid nodules (p = 0.0039) on the other hand. No significant difference of diagnostic accuracy for the diagnosis of malignant thyroid nodules was found between RTE and ARFI-imaging (0.74 vs. 0.69, p = 0.54). The combination of RTE with ARFI did not improve diagnostic accuracy.
Conclusions: ARFI can be used as an additional tool in the diagnostic work up of thyroid nodules with high negative predictive value and comparable results to RTE
Cost-effectiveness of non-invasive methods for assessment and monitoring of liver fibrosis and cirrhosis in patients with chronic liver disease: systematic review and economic evaluation
BACKGROUND: Liver biopsy is the reference standard for diagnosing the extent of fibrosis in chronic liver disease; however, it is invasive, with the potential for serious complications. Alternatives to biopsy include non-invasive liver tests (NILTs); however, the cost-effectiveness of these needs to be established. OBJECTIVE: To assess the diagnostic accuracy and cost-effectiveness of NILTs in patients with chronic liver disease. DATA SOURCES: We searched various databases from 1998 to April 2012, recent conference proceedings and reference lists. METHODS: We included studies that assessed the diagnostic accuracy of NILTs using liver biopsy as the reference standard. Diagnostic studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Meta-analysis was conducted using the bivariate random-effects model with correlation between sensitivity and specificity (whenever possible). Decision models were used to evaluate the cost-effectiveness of the NILTs. Expected costs were estimated using a NHS perspective and health outcomes were measured as quality-adjusted life-years (QALYs). Markov models were developed to estimate long-term costs and QALYs following testing, and antiviral treatment where indicated, for chronic hepatitis B (HBV) and chronic hepatitis C (HCV). NILTs were compared with each other, sequential testing strategies, biopsy and strategies including no testing. For alcoholic liver disease (ALD), we assessed the cost-effectiveness of NILTs in the context of potentially increasing abstinence from alcohol. Owing to a lack of data and treatments specifically for fibrosis in patients with non-alcoholic fatty liver disease (NAFLD), the analysis was limited to an incremental cost per correct diagnosis. An analysis of NILTs to identify patients with cirrhosis for increased monitoring was also conducted. RESULTS: Given a cost-effectiveness threshold of £20,000 per QALY, treating everyone with HCV without prior testing was cost-effective with an incremental cost-effectiveness ratio (ICER) of £9204. This was robust in most sensitivity analyses but sensitive to the extent of treatment benefit for patients with mild fibrosis. For HBV [hepatitis B e antigen (HBeAg)-negative)] this strategy had an ICER of £28,137, which was cost-effective only if the upper bound of the standard UK cost-effectiveness threshold range (£30,000) is acceptable. For HBeAg-positive disease, two NILTs applied sequentially (hyaluronic acid and magnetic resonance elastography) were cost-effective at a £20,000 threshold (ICER: £19,612); however, the results were highly uncertain, with several test strategies having similar expected outcomes and costs. For patients with ALD, liver biopsy was the cost-effective strategy, with an ICER of £822. LIMITATIONS: A substantial number of tests had only one study from which diagnostic accuracy was derived; therefore, there is a high risk of bias. Most NILTs did not have validated cut-offs for diagnosis of specific fibrosis stages. The findings of the ALD model were dependent on assuptions about abstinence rates assumptions and the modelling approach for NAFLD was hindered by the lack of evidence on clinically effective treatments. CONCLUSIONS: Treating everyone without NILTs is cost-effective for patients with HCV, but only for HBeAg-negative if the higher cost-effectiveness threshold is appropriate. For HBeAg-positive, two NILTs applied sequentially were cost-effective but highly uncertain. Further evidence for treatment effectiveness is required for ALD and NAFLD. STUDY REGISTRATION: This study is registered as PROSPERO CRD42011001561. FUNDING: The National Institute for Health Research Health Technology Assessment programme
- …