93 research outputs found

    Combined Anterior Sclera Staphylectomy and Vitrectomy with Anterior Sclera Staphyloma and Vitreous Hemorrhage Occurring 38 Years after Cataract Surgery

    Get PDF
    Introduction. To report a case of anterior sclera staphyloma and vitreous hemorrhage occurring over 38 years after bilateral cataract surgery. Methods. A 58-year-old man presented with anterior sclera staphyloma and vitreous hemorrhage in the right eye, after bilateral cataract surgery, over 38 years ago. We performed combined anterior sclera staphylectomy and vitrectomy of right eye for anterior sclera staphyloma and vitreous hemorrhage. Results. Forty-eight months after the combined surgery, best-corrected visual acuity was 0.3 (+10.00/−4.50 × 60) with eutopic stitches of the corneoscleral junction on the superior nasal quadrant and a stable ocular surface. Conclusions. This is the first reported case of anterior sclera staphyloma with vitreous hemorrhage successfully managed by combined surgery

    Value of multiplanar reconstruction in multi-slice computed tomography for the detection of foreign body in the pulmonary artery: a case report

    No full text
    Multi-slice computed tomography (MSCT) is the primary method for the detection and visualization of foreign bodies in the pulmonary artery because it provides high sensitivity and accuracy. It is very difficult to diagnose a patient with a non-iatrogenic pulmonary artery foreign body who does not have a history of a penetrating trauma. This case report describes a 36-year-old male that presented with coughing and haemoptysis. Based on conventional coronal and cross-sectional CT, the foreign body was misdiagnosed as pulmonary tuberculosis and pulmonary artery thrombosis. During treatment of the bronchial artery embolization and anti-tuberculosis therapy, the patient continued to experience haemoptysis. After further analysis of the pulmonary artery CT angiography images and curved multiplane reconstruction, an approximately 6-cm long toothpick was identified in the pulmonary artery with an unclear entry route. After surgery to remove the toothpick, symptoms of coughing and haemoptysis were resolved. This current case demonstrated that multiplane reconstruction in MSCT can improve the detection and visualization of pulmonary artery foreign bodies, which can aid in the diagnosis of pulmonary artery diseases of unknown cause

    Phacoemulsification surgery in 105-year-old patients

    Full text link

    Short-term effect of a developed warming moist chamber goggle for video display terminal-associated dry eye

    No full text
    Abstract Background Video display terminal (VDT)-associated dry eye (DE) patients are the rising group worldwide, and moisture goggles are the preferable treatment since they are capable of improving tear film stability and DE discomfort. The current study aims to evaluate the short-term efficacy and safety of the developed warming moist chamber goggles (WMCGs) for VDT-associated DE patients. Methods In this prospective self-control study, 22 DE patients (22 eyes) working with VDTs over 4 h daily were enrolled and instructed to wear WMCGs for 15 min. Sodium hyaluronate (SH, 0.1%) eyedrops were applied as a control on another day on these same patients, however 4 subjects denied the eyedrop application. The symptomatology visual analog scale (VAS) score, tear meniscus height (TMH), noninvasive tear film break-up time (NI-BUT), tear film lipid layer thickness (LLT), and bulbar conjunctival redness were assessed with Keratograph 5 M at baseline, 5, 30 and 60 min after treatment. The WMCGs wearing comfort was also evaluated. Results The ocular discomfort evaluated by VAS decreased in the WMCGs group throughout 60 min (P<0.001), better than the control group levels (P ≤ 0.015). TMH, NI-BUT (including the first BUT and average BUT) increased than baseline level accross 60 min in the WMCG group (P ≤ 0.012), while those in the control group only showed temporary improvements in 5 min. LLT also increased obviously after WMCGs wear, while the change in the control group was nearly innoticeable. No adverse responses were detected. Conclusions Temporary use of the WMCGs is able to relieve ocular discomfort, and improves tear film stability in DE patients for at least 1 h, making it a promising alternative to other treatments

    Exfoliation of Metal-Organic Framework Nanosheets Using Surface Acoustic Waves

    No full text
    Two-dimensional (2D) metal-organic framework (MOF) nanosheets have recently received extensive attention due to their ultra-thin thickness, large specific surface area, chemical and functional designability. In this study, an unconventional method using surface acoustic wave (SAW) technology is proposed to exfoliate large quantities and uniform layers of 2D MOF-Zn2(bim)4 nanosheets in a microfluidic system. We successfully demonstrated that the thickness of 2D MOF is effectively and accurately controlled by optimizing the SAW parameters. The mechanisms for the efficient exfoliation of 2D MOF nanosheets is attributed to both the electric and acoustic fields generated by the SAWs in the liquid. The electric field ionizes the methanol to produce H + ions, which intercalate Zn2(bim)4 sheets and weaken the interlayer bonding, and the strong shear force generated by SAWs separates the MOF sheets. A yield of 66 for monolayer MOFs with a maximum size of 3.5 μm is achieved under the combined effect of electric and acoustic fields. This fast, low-energy exfoliation platform has the potential to provide a simple and scalable microfluidic exfoliation method for production of large-area and quantities of 2D MOFs

    Clinical Results of Densiron 68 Intraocular Tamponade for Complicated Retinal Detachment

    Full text link
    &lt;i&gt;Purpose:&lt;/i&gt;To assess the success rates and complications of Densiron 68 intraocular tamponade in the management of complicated retinal detachment (RD) with proliferative vitreoretinopathy (PVR). &lt;i&gt;Methods:&lt;/i&gt;Twenty-one eyes of 20 patients with complicated RD and PVR were included in this prospective study. Vitreoretinal surgery with Densiron 68 intraocular tamponade was performed in all patients. &lt;i&gt;Results:&lt;/i&gt;The success rate with 1 operation using Densiron 68 was 85.7%, and with further surgery 90.5%. Visual acuity improved from a mean logMAR of 2.25 (SD 0.73) to 1.19 (SD 0.88), p = 0.0001. There was little evidence of dispersion and excessive inflammation. &lt;i&gt;Conclusion:&lt;/i&gt;According to the results of this study, vitreoretinal surgery with temporary Densiron 68 intraocular tamponade appears to increase the anatomical success and improve visual acuity, while giving rise to minimal complications, in selected cases of complicated RD and PVR.</jats:p
    corecore