194 research outputs found
Imaging in left-sided VHD
In terms of valvular heart disease (VHD) imaging, transthoracic echocardiography (TTE) is the preferred first choice because of its widespread availability. Other modalities, such as transesophageal echocardiography, computed tomography and magnetic resonance imaging, have played a supplementary role in diagnosis for severity, deciding the timing/type of treatment, detection of post procedural complications, and prognostic predictions. However, there are few consensuses on how to employ these modalities, as the evidence is not extensive as that for TTE. On the other hand, these imaging modalities also have their own unique strengths. If employed properly, these modalities have the potential to play a more prominent role in clinical decision making. In this review, we focus on the potential, limitations and application of current imaging modalities in the management of left-sided VH
GLS following high-dose chemotherapy
Background
Cardiac amyloidosis (CA) is a secondary form of cardiomyopathy where abnormal accumulation of amyloid protein in the myocardial interstitium causes cardiac hypertrophy and myocardial fibrosis. If primary CA advances to heart failure, most patients do not survive for very long after the diagnosis.
Case summary
A 40-year-old man was admitted to our hospital for dyspnoea, progressive anaemia, and decreased appetite. He has diagnosed with amyloid light-chain (AL) amyloidosis. Although BD treatment (bortezomib + dexamethasone) and medical treatment were started, there was no sign of improvement. Then, high-dose chemotherapy followed by autologous peripheral blood stem cell transplantation (auto-PBSCT) was initiated. Pretreatment echocardiography revealed typical findings of CA, such as ventricular wall thickening, valvular thickening, diastolic dysfunction, and pericardial effusion. Global longitudinal strain (GLS) was significantly reduced, and bull's-eye mapping showed typical apical sparing. After auto-PBSCT, GLS gradually improved and was almost normal after 2 years. Other echocardiographic parameters, functional status, and laboratory data also showed that there was significant regression of CA.
Discussion
Although the prognosis in primary CA is extremely poor, we achieved long-term survival in a patient with effective high-dose chemotherapy and auto-PBSCT. Global longitudinal strain may be a useful marker of prognosis, regression, and recovery
Reducing echocardiographic examination time through routine use of fully automated software : a comparative study of measurement and report creation time
Background
Manual interpretation of echocardiographic data is time-consuming and operator-dependent. With the advent of artificial intelligence (AI), there is a growing interest in its potential to streamline echocardiographic interpretation and reduce variability. This study aimed to compare the time taken for measurements by AI to that by human experts after converting the acquired dynamic images into DICOM data.
Methods
Twenty-three consecutive patients were examined by a single operator, with varying image quality and different medical conditions. Echocardiographic parameters were independently evaluated by human expert using the manual method and the fully automated US2.ai software. The automated processes facilitated by the US2.ai software encompass real-time processing of 2D and Doppler data, measurement of clinically important variables (such as LV function and geometry), automated parameter assessment, and report generation with findings and comments aligned with guidelines. We assessed the duration required for echocardiographic measurements and report creation.
Results
The AI significantly reduced the measurement time compared to the manual method (159 ± 66 vs. 325 ± 94 s, p < 0.01). In the report creation step, AI was also significantly faster compared to the manual method (71 ± 39 vs. 429 ± 128 s, p < 0.01). The incorporation of AI into echocardiographic analysis led to a 70% reduction in measurement and report creation time compared to manual methods. In cases with fair or poor image quality, AI required more corrections and extended measurement time than in cases of good image quality. Report creation time was longer in cases with increased report complexity due to human confirmation of AI-generated findings.
Conclusions
This fully automated software has the potential to serve as an efficient tool for echocardiographic analysis, offering results that enhance clinical workflow by providing rapid, zero-click reports, thereby adding significant value
Deep learning to predict elevated pulmonary artery pressure in patients with suspected pulmonary hypertension using standard chest X ray
Accurate diagnosis of pulmonary hypertension (PH) is crucial to ensure that patients receive timely treatment. We hypothesized that application of artificial intelligence (AI) to the chest X-ray (CXR) could identify elevated pulmonary artery pressure (PAP) and stratify the risk of heart failure hospitalization with PH. We retrospectively enrolled a total of 900 consecutive patients with suspected PH. We trained a convolutional neural network to identify patients with elevated PAP (> 20 mmHg) as the actual value of PAP. The endpoints in this study were admission or occurrence of heart failure with elevated PAP. In an independent evaluation set for detection of elevated PAP, the area under curve (AUC) by the AI algorithm was significantly higher than the AUC by measurements of CXR images and human observers (0.71 vs. 0.60 and vs. 0.63, all p < 0.05). In patients with AI predicted PH had 2-times the risk of heart failure with PH compared with those without AI predicted PH. This preliminary work suggests that applying AI to the CXR in high risk groups has limited performance when used alone in identifying elevated PAP. We believe that this report can serve as an impetus for a future large study
Echocardiographic artificial intelligence for pulmonary hypertension classification
Objective: The classification of pulmonary hypertension (PH) is crucial for determining the appropriate therapeutic strategy. We investigated whether machine learning (ML) algorithms may assist in echocardiographic PH prediction, where current guidelines recommend integrating several different parameters.
Methods: We obtained physical and echocardiographic data from 885 patients who underwent right heart catheterization (RHC). Patients were classified into three groups: non-PH, pre-capillary PH, and post-capillary PH, based on values obtained from RHC. Utilizing 24 parameters, we created predictive models employing four different classifiers and selected the one with the highest area under the curve (AUC). We then calculated the macro-average classification accuracy for PH on the derivation cohort (n=720) and prospective validation dataset (n=165), comparing the results with guideline-based echocardiographic assessment obtained from each cohort.
Results: Logistic regression with elastic net regularization had the highest classification accuracy, with AUCs of 0.789, 0.766, and 0.742 for normal, pre-capillary PH, and post-capillary PH, respectively. The ML model demonstrated significantly better predictive accuracy than the guideline-based echocardiographic assessment in the derivation cohort (59.4% vs. 51.6%, p<0.01). In the independent validation dataset, the ML model's accuracy was comparable to the guideline-based PH classification (59.4% vs. 57.8%, p=0.638).
Conclusions: This preliminary study suggests promising potential for our ML model in predicting echocardiographic PH. Further research and validation are needed to fully assess its clinical utility in PH diagnosis and treatment decision-making
Artificial intelligence-assisted interpretation of systolic function by echocardiogram
Objective: Precise and reliable echocardiographic assessment of left ventricular ejection fraction (LVEF) is needed for clinical decision-making. Recently, artificial intelligence (AI) models have been developed to estimate LVEF accurately. The aim of this study was to evaluate whether an AI model could estimate an expert read of LVEF and reduce the interinstitutional variability of level 1 readers with the AI-LVEF displayed on the echocardiographic screen.
Methods: This prospective, multicentre echocardiographic study was conducted by five cardiologists of level 1 echocardiographic skill (minimum level of competency to interpret images) from different hospitals. Protocol 1: Visual LVEFs for the 48 cases were measured without input from the AI-LVEF. Protocol 2: the 48 cases were again shown to all readers with inclusion of AI-LVEF data. To assess the concordance and accuracy with or without AI-LVEF, each visual LVEF measurement was compared with an average of the estimates by five expert readers as a reference.
Results: A good correlation was found between AI-LVEF and reference LVEF (r=0.90, p<0.001) from the expert readers. For the classification LVEF, the area under the curve was 0.95 on heart failure with preserved EF and 0.96 on heart failure reduced EF. For the precision, the SD was reduced from 6.1±2.3 to 2.5±0.9 (p<0.001) with AI-LVEF. For the accuracy, the root-mean squared error was improved from 7.5±3.1 to 5.6±3.2 (p=0.004) with AI-LVEF.
Conclusions: AI can assist with the interpretation of systolic function on an echocardiogram for level 1 readers from different institutions
Clinically Feasible and Accurate View Classification of Echocardiographic Images Using Deep Learning
A proper echocardiographic study requires several video clips recorded from different acquisition angles for observation of the complex cardiac anatomy. However, these video clips are not necessarily labeled in a database. Identification of the acquired view becomes the first step of analyzing an echocardiogram. Currently, there is no consensus whether the mislabeled samples can be used to create a feasible clinical prediction model of ejection fraction (EF). The aim of this study was to test two types of input methods for the classification of images, and to test the accuracy of the prediction model for EF in a learning database containing mislabeled images that were not checked by observers. We enrolled 340 patients with five standard views (long axis, short axis, 3-chamber view, 4-chamber view and 2-chamber view) and 10 images in a cycle, used for training a convolutional neural network to classify views (total 17,000 labeled images). All DICOM images were rigidly registered and rescaled into a reference image to fit the size of echocardiographic images. We employed 5-fold cross validation to examine model performance. We tested models trained by two types of data, averaged images and 10 selected images. Our best model (from 10 selected images) classified video views with 98.1% overall test accuracy in the independent cohort. In our view classification model, 1.9% of the images were mislabeled. To determine if this 98.1% accuracy was acceptable for creating the clinical prediction model using echocardiographic data, we tested the prediction model for EF using learning data with a 1.9% error rate. The accuracy of the prediction model for EF was warranted, even with training data containing 1.9% mislabeled images. The CNN algorithm can classify images into five standard views in a clinical setting. Our results suggest that this approach may provide a clinically feasible accuracy level of view classification for the analysis of echocardiographic data
AI for Exercise-Induced Pulmonary Hypertension
Background: Stress echocardiography is an emerging tool used to detect exercise-induced pulmonary hypertension (EIPH). However, facilities that can perform stress echocardiography are limited by issues such as cost and equipment.
Objective: We evaluated the usefulness of a deep learning (DL) approach based on a chest X-ray (CXR) to predict EIPH in 6-min walk stress echocardiography.
Methods: The study enrolled 142 patients with scleroderma or mixed connective tissue disease with scleroderma features who performed a 6-min walk stress echocardiographic test. EIPH was defined by abnormal cardiac output (CO) responses that involved an increase in mean pulmonary artery pressure (mPAP). We used the previously developed AI model to predict PH and calculated PH probability in this cohort.
Results: EIPH defined as ΔmPAP/ΔCO >3.3 and exercise mPAP >25 mmHg was observed in 52 patients, while non-EIPH was observed in 90 patients. The patients with EIPH had a higher mPAP at rest than those without EIPH. The probability of PH based on the DL model was significantly higher in patients with EIPH than in those without EIPH. Multivariate analysis showed that gender, mean PAP at rest, and the probability of PH based on the DL model were independent predictors of EIPH. A model based on baseline parameters (age, gender, and mPAP at rest) was improved by adding the probability of PH predicted by the DL model (AUC: from 0.65 to 0.74; p = 0.046).
Conclusion: Applying the DL model based on a CXR may have a potential for detection of EIPH in the clinical setting
- …