2,063 research outputs found
High pressure space suit glove
The High Pressure Space Suit Glove Program yielded one prototype glove assembly with an operating pressure of 8.0 psi. The following developments are reported: (1) A new layup technique for incorporation of the mini-convolute systems; (2) modification in the mini-convolute construction to assure cycle life at 8.0 psi in excess of 100,000 cycles; (3) the development of a unique non-orthogonal low torque wrist joint; (4) the development of a low torque single axis joint for use in the thumb and finger first metacarpal joints; and (5) a number of approaches to 1st metacarpal joints were fabricated and tested to establish the joint technqiues
Liquid-cooled liner for helmets
Liner acts as coolant tubing, manifold, and supporting structures. Fabric of waffle-design is made of several integrated channels (or capillaries) through which coolant liquid can flow. Thin and light-weight liner can be incorporated into any type of helmet or head gear
Convoluted fabric for full-pressure gloves
Fabric, made of nylon ripstop coated with Neoprene, provides expansive and contractive mobility along posterior surface of glove fingers allowing maximum digital dexterity and tactility
Liquid cooled brassiere and method of diagnosing malignant tumors therewith
A device for enhancing the detection of malignant tissue in the breasts of a woman was described. A brassiere-like garment which is fitted with a pair of liquid-perfused cooling panels which completely and compliantly cover the breasts and upper torso was studied. The garment is connected by plastic tubing to a liquid cooling system comprising a fluid pump, a solenoid control valve for controlling the flow of fluid to either the cooling unit or the heating unit, a fluid reservoir, a temperature sensor in the reservoir, and a restrictor valve to control the pressure in the garment inlet cooling line
Double window viewing chamber assembly
A viewing chamber which permits observation of a sample retained therein includes a pair of double window assemblies mounted in opposed openings in the walls thereof so that a light beam can directly enter and exit from the chamber. A flexible mounting arrangement for the outer windows of the window assemblies enables the windows to be brought into proper alignment. An electrical heating arrangement prevents fogging of the outer windows whereas desiccated air in the volume between the outer and inner windows prevents fogging of the latter
Phase 2, 3 and 4 8 psi pressure glove
The feasibility of providing a high pressure, very mobile and reliable space suit glove system is demonstrated. A 'soft' toroidal wrist joint assembly was developed. A representative Kevlar and steel wrist section was tested and proved the useful lifetime to be in excess of 1,000,000 cycles. Improved comfort was accomplished by increasing the first finger metacarpal dimensions. Recommendations concern design refinements, and EVA configuration
Advanced extravehicular mobility unit study
Components of the advanced extravehicular mobility unit (suit) are described. Design considerations for radiation protection, extravehicular operational pressure, mobility effects, tool/glove/effector, anthropometric definition, lighting, and equipment turnaround are addressed
EV space suit gloves (passive)
A pair of pressure and thermal insulating overgloves to be used with an Extravehicular (EV) suit assembly was designed, developed, fabricated, and tested. The design features extensive use of Nomex felt materials in lieu of the multiple layer insulation formerly used with the Apollo thermal glove. The glove theoretically satisfies all of the thermal requirements. The presence of the thermal glove does not degrade pressure glove tactility by more than the acceptable 10% value. On the other hand, the thermal glove generally degrades pressure glove mobility by more than the acceptable 10% value, primarily in the area of the fingers. Life cycling tests were completed with minimal problems. The thermal glove/pressure glove ensemble was also tested for comfort; the test subjects found no problems with the thermal glove although they did report difficulties with pressure points on the pressure glove which were independent of the thermal glove
Hypnosis for acute procedural pain: a critical review
Clinical evidence for the effectiveness of hypnosis in the treatment of acute procedural pain was critically evaluated based on reports from randomized controlled clinical trials (RCTs). Results from the 29 RCTs meeting inclusion criteria suggest that hypnosis decreases pain compared to standard care and attention control groups and that it is at least as effective as comparable adjunct psychological or behavioral therapies. In addition, applying hypnosis in multiple sessions prior to the day of the procedure produced the highest percentage of significant results. Hypnosis was most effective in minor surgical procedures. However, interpretations are limited by considerable risk of bias. Further studies using minimally effective control conditions and systematic control of intervention dose and timing are required to strengthen conclusions
A flexible flight display research system using a ground-based interactive graphics terminal
Requirements and research areas for the air transportation system of the 1980 to 1990's were reviewed briefly to establish the need for a flexible flight display generation research tool. Specific display capabilities required by aeronautical researchers are listed and a conceptual system for providing these capabilities is described. The conceptual system uses a ground-based interactive graphics terminal driven by real-time radar and telemetry data to generate dynamic, experimental flight displays. These displays are scan converted to television format, processed, and transmitted to the cockpits of evaluation aircraft. The attendant advantages of a Flight Display Research System (FDRS) designed to employ this concept are presented. The detailed implementation of an FDRS is described. The basic characteristics of the interactive graphics terminal and supporting display electronic subsystems are presented and the resulting system capability is summarized. Finally, the system status and utilization are reviewed
- …