5,478 research outputs found
A novel on-line cable PD localisation method based on cable transfer function and detected PD pulse rise-time
CW-pumped telecom band polarization entangled photon pair generation in a Sagnac interferometer
A polarization entangled photon pair source is widely used in many quantum
information processing applications such as teleportation, quantum swapping,
quantum computation and high precision quantum metrology. Here, we report on
the generation of a continuous-wave pumped degenerated 1550 nm polarization
entangled photon pair source at telecom wavelength using a type-II
phase-matched periodically poled KTiOPO4 crystal in a Sagnac interferometer.
Hong-Ou-Mandel-type interference measurement shows the photon bandwidth of 2.4
nm. High quality of entanglement is verified by various kinds of measurements,
for example two-photon interference fringes, Bell inequality and quantum states
tomography. The wavelength of photons can be tuned over a broad range by
changing the temperature of crystal or pump power without losing the quality of
entanglement. This source will be useful for building up long-distance quantum
networks
Partial discharge pulse propagation in power cable and partial discharge monitoring system
Partial discharge (PD) based condition monitoring has been widely applied to power cables. However, difficulties in interpretation of measurement results (location and criticality) remain to be tackled. This paper aims to develop further knowledge in PD signal propagation in power cables and attenuation by the PD monitoring system devices to address the localization and criticality issues. As on-line or in-service PD monitoring sensors commonly comprise of a high frequency current transformer (HFCT) and a high-pass filter, the characteristics of detected PD pulses depend on the attenuation of the cable, the HFCT used and the filter applied. Simulation of pulse propagation in a cable and PD monitoring system are performed, based on analyses in the frequency domain using the concept of transfer functions. Results have been verified by laboratory experiments and using on-site PD measurements. The knowledge gained from the research on the change in pulse characteristics propagating in a cable and through a PD detection system can be very useful to PD denoising and for development of a PD localization technique
Efficient infrared upconversion via a ladder-type atomic configuration
We have demonstrated experimentally that infrared light at 1529.4nm can be
converted into the visible at 780nm with 54% efficiency through a ladder-type
atomic configuration in 85Rb. Specifically we theoretically analyze that high
efficiency is due to the large nonlinear dispersion of the index of refraction
from the off-resonant enhancement in a four-wave mixing (FWM) process. By using
two perpendicular polarized pump fields, the coherence of two FWM processes in
this configuration is verified.Comment: The new version is published in Journal of Modern Optic
- …