Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures - Fig 1
<p>(a) Blade Screw DHS (ODRC Dynamic Hip Screw System, Chin Bone Corp., Taiwan; US FDA 510(k): K103015). (b) Radiographs of an 101 years-old woman showing fixation with a Blade Screw DHS post-operation. (c) The design and components of Blade Screw DHS.</p
A femoral head test model was fixed in the HIPS system and subjected to multi-axial loading.
<p>A femoral head test model was fixed in the HIPS system and subjected to multi-axial loading.</p
(a) Size of a test block; (b) Cellular rigid polyurethane foam (Type 1522–11) used to simulate a mild osteoporotic bone; (c) Open-cell rigid polyurethane foam (Type 1522–524) used to simulate a severely osteoporotic bone.
<p>(a) Size of a test block; (b) Cellular rigid polyurethane foam (Type 1522–11) used to simulate a mild osteoporotic bone; (c) Open-cell rigid polyurethane foam (Type 1522–524) used to simulate a severely osteoporotic bone.</p
(a) Specimen after lag screw excessive migration (≥10 mm); (b) TAD values of the Blade Screw and traditional DHS groups immediately after surgery and at 3-months follow-up.
<p>(a) Specimen after lag screw excessive migration (≥10 mm); (b) TAD values of the Blade Screw and traditional DHS groups immediately after surgery and at 3-months follow-up.</p
Anterior-posterior translations of medial and lateral tibial compartments in the reconstructed knee joint with different graft strengths.
<p>The anterior-posterior translations of the medial tibial compartment are noticeably affected by the graft strength.</p
Finite element model of human knee including the femur, tibia, fibula, articular cartilage layers, menisci, and four main ligaments.
<p>Finite element model of human knee including the femur, tibia, fibula, articular cartilage layers, menisci, and four main ligaments.</p
The in-situ forces in the grafts with different strengths under a 100 N posterior tibial force.
<p>The in-situ forces and graft strengths represented a proportional relationship.</p
Tibial rotations in the reconstructed knee joint with different graft strengths.
<p>Internal tibial rotation occurred in the PCL fully-ruptured knee model. In all PCL reconstruction cases the tibia rotated externally.</p
Maximum load, stiffness, and elongation at failure load.
<p>Maximum load, stiffness, and elongation at failure load.</p
Recommended from our members