14 research outputs found

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Firefly Light Flashing: Oxygen Supply Mechanism

    No full text
    Firefly luminescence is an intriguing phenomenon with potential technological applications, whose biochemistry background was only recently established. The physics side of this phenomenon, however, was still unclear, specifically as far as the oxygen supply mechanism for light flashing is concerned. This uncertainty is due to the complex microscopic structure of the tracheal system: without fully knowing its geometry, one cannot reliably test the proposed mechanisms. We solved this problem using synchrotron phase contrast microtomography and transmission x-ray microscopy, finding that the oxygen consumption corresponding to mitochondria functions exceeds the maximum rate of oxygen diffusion from the tracheal system to the photocytes. Furthermore, the flashing mechanism uses a large portion of this maximum rate. Thus, the flashing control requires passivation of the mitochondria functions, e.g., by nitric oxide, and switching of the oxygen supply from them to photoluminescence

    Robust estimation of bacterial cell count from optical density [Elektronisk resurs]

    No full text
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.AuthorOverflow(1393

    Author Correction: Robust estimation of bacterial cell count from optical density

    No full text
    An amendment to this paper has been published and can be accessed via a link at the top of the paper.</jats:p

    Robust estimation of bacterial cell count from optical density

    No full text
    AbstractOptical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals  &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.</jats:p

    Bioinformatics and Translation Elongation

    No full text

    Fundamentals of Proteomics

    No full text
    corecore