32,245 research outputs found
Non-Contact Temperature Requirements (NCTM) for drop and bubble physics
Many of the materials research experiments to be conducted in the Space Processing program require a non-contaminating method of manipulating and controlling weightless molten materials. In these experiments, the melt is positioned and formed within a container without physically contacting the container's wall. An acoustic method, which was developed by Professor Taylor G. Wang before coming to Vanderbilt University from the Jet Propulsion Laboratory, has demonstrated the capability of positioning and manipulating room temperature samples. This was accomplished in an earth-based laboratory with a zero-gravity environment of short duration. However, many important facets of high temperature containerless processing technology have not been established yet, nor can they be established from the room temperature studies, because the details of the interaction between an acoustic field an a molten sample are largely unknown. Drop dynamics, bubble dynamics, coalescence behavior of drops and bubbles, electromagnetic and acoustic levitation methods applied to molten metals, and thermal streaming are among the topics discussed
Method and apparatus for producing microshells
A method is described for forming hollow particles, or shells, of extremely small size. The shell material is heated to a molten temperature in the presence of a gas that is at least moderately soluble in the shell material, to form a solution of the molten shell material and the soluble gas. The solution is atomized to form a multiplicity of separate droplets that are cooled while in free fall. Cooling of a droplet from the outside traps the desolved gas and forces it to form a gas bubble at the center of the droplet which now forms a gas filled shell. The shell is reheated and then cooled in free fall, in an environment having a lower pressure than the gas pressure in the shell. This causes expansion of the shell and the formation of a shell having a small wall thickness compared to its diameter
Stability of an Ultra-Relativistic Blast Wave in an External Medium with a Steep Power-Law Density Profile
We examine the stability of self-similar solutions for an accelerating
relativistic blast wave which is generated by a point explosion in an external
medium with a steep radial density profile of a power-law index > 4.134. These
accelerating solutions apply, for example, to the breakout of a gamma-ray burst
outflow from the boundary of a massive star, as assumed in the popular
collapsar model. We show that short wavelength perturbations may grow but only
by a modest factor <~ 10.Comment: 12 pages, 3 figures, submitted to Physical Review
Immunoisolation Patch System for Cellular Transplantation
An immunoisolation patch system, and particularly a patch system comprising multiple immunoisolation microcapsules, each encapsulating biological material such as cells for transplantation, which can be used in the prophylactic and therapeutic treatment of disease in large animals and humans without the need for immunosuppression
Sphere based fluid systems
Systems are described for using multiple closely-packed spheres. In one system for passing fluid, a multiplicity of spheres lie within a container, with all of the spheres having the same outside diameter and with the spheres being closely nested in one another to create multiple interstitial passages of a known size and configuration and smooth walls. The container has an inlet and outlet for passing fluid through the interstitial passages formed between the nested spheres. The small interstitial passages can be used to filter out material, especially biological material such as cells in a fluid, where the cells can be easily destroyed if passed across sharp edges. The outer surface of the spheres can contain a material that absorbs a constitutent in the flowing fluid, such as a particular contamination gas, or can contain a catalyst to chemically react the fluid passing therethrough, the use of multiple small spheres assuring a large area of contact of these surfaces of the spheres with the fluid. In a system for storing and releasing a fluid such as hydrogen as a fuel, the spheres can include a hollow shell containing the fluid to be stored, and located within a compressable container that can be compressed to break the shells and release the stored fluid
A Measure of the Proportion of Treatment Effect Explained by a Surrogate Marker
Randomized clinical trials with rare primary endpoints or long duration times are costly. Because of this, there has been increasing interest in replacing the true endpoint with an earlier measured marker. However, surrogate markers must be appropriately validated. A quantitative measure for the proportion of treatment effect explained by the marker in a specific trial is a useful concept. Freedman, Graubard, and Schatzkin (1992, Statistics in Medicine 11, 167–178) suggested such a measure of surrogacy by the ratio of regression coefficients for the treatment indicator from two separate models with or without adjusting for the surrogate marker. However, it has been shown that this measure is very variable and there is no guarantee that the two models both fit. In this article, we propose alternative measures of the proportion explained that adapts an idea in Tsiatis, DeGruttola, and Wulfsohn (1995, Journal of the American Statistical Association 90 , 27–37). The new measures require fewer assumptions in estimation and allow more flexibility in modeling. The estimates of these different measures are compared using data from an ophthalmology clinical trial and a series of simulation studies. The results suggest that the new measures are less variable.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65535/1/j.0006-341X.2002.00803.x.pd
Network connectivity during mergers and growth: optimizing the addition of a module
The principal eigenvalue of a network's adjacency matrix often
determines dynamics on the network (e.g., in synchronization and spreading
processes) and some of its structural properties (e.g., robustness against
failure or attack) and is therefore a good indicator for how ``strongly'' a
network is connected. We study how is modified by the addition of a
module, or community, which has broad applications, ranging from those
involving a single modification (e.g., introduction of a drug into a biological
process) to those involving repeated additions (e.g., power-grid and transit
development). We describe how to optimally connect the module to the network to
either maximize or minimize the shift in , noting several applications
of directing dynamics on networks.Comment: 7 pages, 5 figure
The Bloch-Okounkov correlation functions, a classical half-integral case
Bloch and Okounkov's correlation function on the infinite wedge space has
connections to Gromov-Witten theory, Hilbert schemes, symmetric groups, and
certain character functions of \hgl_\infty-modules of level one. Recent works
have calculated these character functions for higher levels for \hgl_\infty
and its Lie subalgebras of classical type. Here we obtain these functions for
the subalgebra of type of half-integral levels and as a byproduct, obtain
-dimension formulas for integral modules of type at half-integral level.Comment: v2: minor changes to the introduction; accepted for publication in
Letters in Mathematical Physic
Reply to "Comment on 'Fano resonance for Anderson Impurity Systems' "
In a recent Comment, Kolf et al. (cond-mat/0503669) state that our analysis
of the Fano resonance for Anderson impurity systems [Luo et al., Phys. Rev.
Lett 92, 256602 (2004)] is incorrect. Here we want to point out that their
comments are not based on firm physical results and their criticisms are
unjustified and invalid.Comment: 1 page, 1 figure, to appear in PR
Reactor for making uniform capsules
The present invention provides a novel reactor for making capsules with uniform membrane. The reactor includes a source for providing a continuous flow of a first liquid through the reactor; a source for delivering a steady stream of drops of a second liquid to the entrance of the reactor; a main tube portion having at least one loop, and an exit opening, where the exit opening is at a height substantially equal to the entrance. In addition, a method for using the novel reactor is provided. This method involves providing a continuous stream of a first liquid; introducing uniformly-sized drops of the second liquid into the stream of the first liquid; allowing the drops to react in the stream for a pre-determined period of time; and collecting the capsules
- …