2,491 research outputs found

    Optimization of a 65 nm CMOS imaging process for monolithic CMOS sensors for high energy physics

    Get PDF
    The long term goal of the CERN Experimental Physics Department R&D on monolithic sensors is the development of sub-100nm CMOS sensors for high energy physics. The first technology selected is the TPSCo 65nm CMOS imaging technology. A first submission MLR1 included several small test chips with sensor and circuit prototypes and transistor test structures. One of the main questions to be addressed was how to optimize the sensor in the presence of significant in-pixel circuitry. In this paper this optimization is described as well as the experimental results from the MLR1 run confirming its effectiveness. A second submission investigating wafer-scale stitching has just been completed. This work has been carried out in strong synergy with the ITS3 upgrade of the ALICE experiment

    Optimization of a 65 nm CMOS imaging process for monolithic CMOS sensors for high energy physics

    Get PDF
    The long term goal of the CERN Experimental Physics Department R&D on monolithic sensors is the development of sub-100nm CMOS sensors for high energy physics. The first technology selected is the TPSCo 65nm CMOS imaging technology. A first submission MLR1 included several small test chips with sensor and circuit prototypes and transistor test structures. One of the main questions to be addressed was how to optimize the sensor in the presence of significant in-pixel circuitry. In this paper this optimization is described as well as the experimental results from the MLR1 run confirming its effectiveness. A second submission investigating wafer-scale stitching has just been completed. This work has been carried out in strong synergy with the ITS3 upgrade of the ALICE experiment

    Acute diverticulitis management: evolving trends among Italian surgeons. A survey of the Italian Society of Colorectal Surgery (SICCR)

    Get PDF
    Acute diverticulitis (AD) is associated with relevant morbidity/mortality and is increasing worldwide, thus becoming a major issue for national health systems. AD may be challenging, as clinical relevance varies widely, ranging from asymptomatic picture to life-threatening conditions, with continuously evolving diagnostic tools, classifications, and management. A 33-item-questionnaire was administered to residents and surgeons to analyze the actual clinical practice and to verify the real spread of recent recommendations, also by stratifying surgeons by experience. CT-scan remains the mainstay of AD assessment, including cases presenting with recurrent mild episodes or women of child-bearing age. Outpatient management of mild AD is slowly gaining acceptance. A conservative management is preferred in non-severe cases with extradigestive air or small/non-radiologically drainable abscesses. In severe cases, a laparoscopic approach is preferred, with a non-negligible number of surgeons confident in performing emergency complex procedures. Surgeons are seemingly aware of several options during emergency surgery for AD, since the rate of Hartmann procedures does not exceed 50% in most environments and damage control surgery is spreading in life-threatening cases. Quality of life and history of complicated AD are the main indications for delayed colectomy, which is mostly performed avoiding the proximal vessel ligation, mobilizing the splenic flexure and performing a colorectal anastomosis. ICG is spreading to check anastomotic stumps' vascularization. Differences between the two experience groups were found about the type of investigation to exclude colon cancer (considering the experience only in terms of number of colectomies performed), the size of the peritoneal abscess to be drained, practice of damage control surgery and the attitude towards colovesical fistula

    How future surgery will benefit from SARS-COV-2-related measures: a SPIGC survey conveying the perspective of Italian surgeons

    Get PDF
    COVID-19 negatively affected surgical activity, but the potential benefits resulting from adopted measures remain unclear. The aim of this study was to evaluate the change in surgical activity and potential benefit from COVID-19 measures in perspective of Italian surgeons on behalf of SPIGC. A nationwide online survey on surgical practice before, during, and after COVID-19 pandemic was conducted in March-April 2022 (NCT:05323851). Effects of COVID-19 hospital-related measures on surgical patients' management and personal professional development across surgical specialties were explored. Data on demographics, pre-operative/peri-operative/post-operative management, and professional development were collected. Outcomes were matched with the corresponding volume. Four hundred and seventy-three respondents were included in final analysis across 14 surgical specialties. Since SARS-CoV-2 pandemic, application of telematic consultations (4.1% vs. 21.6%; p < 0.0001) and diagnostic evaluations (16.4% vs. 42.2%; p < 0.0001) increased. Elective surgical activities significantly reduced and surgeons opted more frequently for conservative management with a possible indication for elective (26.3% vs. 35.7%; p < 0.0001) or urgent (20.4% vs. 38.5%; p < 0.0001) surgery. All new COVID-related measures are perceived to be maintained in the future. Surgeons' personal education online increased from 12.6% (pre-COVID) to 86.6% (post-COVID; p < 0.0001). Online educational activities are considered a beneficial effect from COVID pandemic (56.4%). COVID-19 had a great impact on surgical specialties, with significant reduction of operation volume. However, some forced changes turned out to be benefits. Isolation measures pushed the use of telemedicine and telemetric devices for outpatient practice and favored communication for educational purposes and surgeon-patient/family communication. From the Italian surgeons' perspective, COVID-related measures will continue to influence future surgical clinical practice

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector