449 research outputs found

    Occupational dental erosion from exposure to acids—a review

    Get PDF
    Objective Dental erosion is characterized as a disorder with a multifactorial aetiology including environmental acid exposure. The purpose of this article was to summarize and discuss the available information concerning occupational dental erosion. Methods Information from original scientific papers, case reports and reviews with additional case reports listed in PubMed, Medline or EMBASE [search term: (dental OR enamel OR dentin) AND (erosion OR tooth wear) AND (occupational OR worker)] were included in the review. References from the identified publications were manually searched to identify additional relevant articles. Results The systematic search resulted in 59 papers, of which 42 were suitable for the present review. Seventeen papers demonstrated evidence that battery, galvanizing and associated workers exposed to sulphuric or hydrochloric acid were at higher risk of dental erosion. For other industrial workers, wine tasters and competitive swimmers, only a few clinical studies exist and these do not allow the drawing of definitive conclusions. Conclusion Occupational acid exposure might increase the risk of dental erosion. Evidence for occupational dental erosion is limited to battery and galvanizing workers, while data for other occupational groups need to be confirmed by further studie

    Colour improvement and stability of white spot lesions following infiltration, micro-abrasion, or fluoride treatments in vitro

    Get PDF
    SUMMARYBACKGROUND/OBJECTIVES: White spot lesions (WSLs) are unwelcome side effects of fixed appliances that compromise the treatment outcome. Recently, infiltration of WSLs has been introduced as a viable treatment alternative. The objective was to evaluate the colour improvement of WSLs and their stability against discolouration following infiltration, fluoride, or micro-abrasion treatments in vitro. MATERIALS/METHODS: Artificial WSLs were created in bovine enamel (N = 96) using acidic buffer solution (pH 5, 10 days) and were randomly allocated to four groups. Specimens were treated with infiltration (Icon, DMG), fluoride (Elmex Caries Protection, GABA), and micro-abrasion (Opalustre, Ultradent) or remained untreated (control). Groups were discoloured for 24 hours in tea or tea + citric acid. Colour components and visible colour change (L*, a*, b*, ΔE) were measured spectrophotometrically on following time points: baseline, after WSL formation, after treatment, and during discolouration (8, 16, and 24 hours). Data were analysed using Kruskal-Wallis and Mann-Whitney tests. RESULTS: WSL formation increased (L*) in all groups. Only infiltration reduced this effect to baseline. Highest ΔE improvement was obtained by infiltration and micro-abrasion followed by fluoride. This improvement was stable only for infiltration during discolouration. L*, a*, and b* changed significantly during discolouration in all groups except infiltration. Within the same treatment group, discolouration solutions did not differ significantly. LIMITATIONS: In vitro testing cannot replicate the actual mode of colour improvement or stability but can be used for ranking materials and techniques. CONCLUSIONS/IMPLICATIONS: Infiltration and micro-abrasion treatments were capable of diminishing the whitish appearance of WSLs. Only infiltrated WSLs were stable following discolouration challeng

    Impact of storage conditions on profilometry of eroded dental hard tissue

    Full text link
    The aim of the present study was to analyze in how far drying of eroded dentin and enamel surfaces influence the results of profilometrical determinations with a stylus profilometer. Each five dentin and enamel samples were eroded with HCl (pH 2.6, 2 min). Surface profiles of the samples were recorded with a stylus profilometer in three series. In series 1, the samples were measured while stored in water and in series 2, under ambient conditions (21 degrees C, 35% humidity). In series 3, samples were completely desiccated and then rewetted. Profilometry was conducted at various time intervals for a period of up to 181 min (series 1 and 2) and 72 h (series 3). Only the dentin samples were affected by the storage conditions. Stable profilometrical readings for the eroded dentin samples were only feasible when the specimens were stored in water during the complete period of the experiment, including the profilometrical measurement. Thus, for erosion experiments using profilometrical analysis with a stylus profilometer, it is advised to store and measure dentin samples under wet conditions

    A new method for chlorhexidine (CHX) determination: CHX release after application of differently concentrated CHX-containing preparations on artificial fissures

    Get PDF
    Aims of the study were (1) to establish a method for quantification of chlorhexidine (CHX) in small volumes and (2) to determine CHX release from differently concentrated CHX-containing preparations, varnishes, and a CHX gel applied on artificial fissures. CHX determination was conducted in a microplate reader using polystyrene wells. The reduced intensity of fluorescence of the microplates was used for CHX quantification. For verification of the technique, intra- and inter-assay coefficients of variation were calculated for graded series of CHX concentrations, and the lower limit of quantification (LLOQ) was determined. Additionally, artificial fissures were prepared in 50 bovine enamel samples, divided into five groups (A-E, n = 10) and stored in distilled water (7days); A: CHX-varnish EC40; B: CHX-varnish Cervitec; C: CHX-gel Chlorhexamed; D: negative control, no CHX application; and E: CXH-diacetate standard (E1, n = 5) or CHX-digluconate (E2, n = 5) in the solution. The specimens were brushed daily, and CHX in the solution was measured. The method showed intra- and inter-assay coefficients of variation of <10 and <20%, respectively; LLOQ was 0.91-1.22nmol/well. The cumulative CHX release (mean ± SD) during the 7days was: EC40 (217.2 ± 41.8nmol), CHX-gel (31.3 ± 8.5nmol), Cervitec (18.6 ± 1.7nmol). Groups A-C revealed a significantly higher CHX release than group D and a continuous CHX-release with the highest increase from day0 to 7 for EC40 and the lowest for Chlorhexamed. The new method is a reliable tool to quantify CHX in small volumes. Both tested varnishes demonstrate prolonged and higher CHX release from artificial fissures than the CHX-gel teste

    Is bovine dentine an appropriate substitute in abrasion studies?

    Get PDF
    The study aimed to compare the wear behaviour of human and bovine dentine due to toothbrushing with different relative dentin abrasivity (RDA) toothpastes. Forty human and 40 bovine dentine samples were prepared from bovine lower incisors or human premolars roots, and baseline surface profiles were recorded. The samples were distributed to four groups (each group n = 10 human and 10 bovine samples) and brushed with fluoridated experimental toothpastes with different RDAs (group A: RDA 10, B: RDA 20, C: RDA 50, and D: RDA 100). Toothbrushing was performed in an automatic brushing machine with a brushing frequency of 60 strokes per minute and a brushing force of 2.5N. After 2, 5, 10, and 25min of toothbrushing, new surface profiles were recorded, and the dentine wear was calculated with a customised computer programme. The dentine wear of human and bovine dentine within the four groups was compared with unpaired t tests. No statistically significant difference was recorded for the dentine wear of human and bovine samples within the different group

    Effect of Caries Infiltrant on Margin Integrity of Composite Fillings Placed Adjacent to Demineralised Primary Enamel

    Full text link
    PURPOSE To investigate the influence of pretreating demineralised enamel with an infiltrant on the margin integrity of Class V like composite restorations on primary teeth bonded with different adhesives. MATERIALS AND METHODS Forty specimens from primary molars were demineralised and circular class-V-like cavities were prepared. The cavities were treated with a universal adhesive (Scotchbond Universal Adhesive, 3M Oral Care), applied either in self-etch (SE) or etch-and-rinse mode (ER) mode. In groups SE-I and ER-I, the demineralised margins were pretreated with a caries infiltrant (Icon, DMG) prior to adhesive application. The cavities were restored with a nanofilled composite material and thermocycled. Marginal integrity was evaluated using SEM, and the percentage of continuous margin was statistically analysed. RESULTS Specimens treated with the caries infiltrant followed by the adhesive showed similar marginal continuity as the adhesive alone. CONCLUSIONS Pretreatment of demineralised primary enamel with a caries infiltrant before applying a universal adhesive does not influence the marginal integrity of composite fillings

    Posttraumatische Verfärbungen

    Get PDF
    Nach einem Zahntrauma mit oder ohne Dislokationsverletzung kann es zu unterschiedlichen Verfärbungen der klinischen Krone kommen. So können graue, rötliche oder gelbliche Farbveränderungen beobachtet werden. Der folgende Beitrag befasst sich mit den Ursachen und Therapiemöglichkeiten der jeweiligen Verfärbung

    Systematic evaluation of the features influencing the accuracy of third order measurements

    Get PDF
    The aims of this study were to evaluate the relationship of third order measurements on dental casts with those on lateral radiographs, and to identify those incisor features on radiographs which can best explain third order measurements on dental casts. Lateral cephalograms and corresponding dental casts were obtained from 39 untreated Caucasians (12 males, 27 females; mean age 19.5 years; standard deviation 3.7 years) with occlusal relationships considered to be ‘normal'. The upper (U1) and lower (L1) incisors were assessed with reference to the occlusal plane perpendicular which was established on the lateral radiographs, including third order angles (U1TR, L1TR) which were also derived from direct dental cast measurements (U1TA, L1TA). Both single regression and multiple linear regression analysis with stepwise variable selection were performed using third order measurements on casts as the dependent variable and crown axis (U1C, L1C), root axis (U1R, L1R), tip-apex connecting line (U1E, L1E), and radiographic third order measurements as independent variables. Single regression analysis indicated an overall difference of 0.02 degrees between radiographic third order inclination and cast assessment in the maxilla (mandible: −2.83 degrees). A change of 1 degree in radiographic third order inclination would produce a change of 0.65 degrees for U1TA and 0.86 degrees for L1TA assessments. Third order measurements on dental casts can best be explained by a linear combination of U1TR and U1E (maxilla) and of L1TR and L1C (mandible) measurements. This study demonstrates the functional enmeshment between two different third order assessments and the most common incisor features on lateral radiographs. Both methods of third order evaluation show sufficient reliability and are appropriate for routine orthodontic practic

    Dynamic interactions between Candida albicans and different streptococcal species in a multispecies oral biofilm

    Get PDF
    The oral cavity is colonized by a plethora of bacteria, fungi, and archaea, including streptococci of the mitis group (MSG) and the yeast Candida albicans. This study aims to investigate the role of streptococcal species in the development of oral biofilm and the cross-kingdom interactions between some of the members of the commensal MSG and the pathogen yeast C. albicans using a multispecies supragingival biofilm model. A total of nine different in vitro biofilms were grown, quantified with culture analyses, and visually examined with confocal laser scanning microscopy (CLSM). A four-species biofilm without any streptococcal species was used as a basic biofilm. In each subsequent inoculum, one species of MSG was added and afterward combined with Streptococcus mutans. The eight-species biofilm contained all eight strains used in this study. Culture analyses showed that the presence of S. mutans in a four-species biofilm with Streptococcus oralis or S. oralis subsp. tigurinus did not differ significantly in C. albicans colony-forming unit (CFU) counts compared to biofilms without S. mutans. However, compared to other mitis species, Streptococcus gordonii combined with S. mutans resulted in the lowest CFUs of C. albicans. Visual observation by CLSM showed that biofilms containing both S. mutans and one species of MSG seemed to induce the formation of filamentous form of C. albicans. However, when several species of MSG were combined with S. mutans, C. albicans was again found in its yeast form

    Polymerization shrinkage and shrinkage force kinetics of high- and low-viscosity dimethacrylate- and ormocer-based bulk-fill resin composites

    Full text link
    The aim of the present study was to investigate polymerization shrinkage, shrinkage force development, and degree of monomer conversion of high- and low-viscosity dimethacrylate- and ormocer-based bulk-fill resin composites. Two flowable bulk-fill composites (SDR, x-tra base), two high-viscosity bulk-fill composites (Bulk Ormocer, SonicFill), and two conventional composite materials (Esthet X flow, Esthet X HD) were photoactivated for 20 s at 1275 mW/cm. Linear polymerization shrinkage and shrinkage force were recorded in real time using custom-made devices, and the force rate and time to achieve maximum force rate were determined. Degree of conversion was measured using Fourier-transform infrared spectroscopy. Data were analyzed with one-way ANOVA and Tukey's HSD post-hoc test, and bivariate correlations were computed (α = 0.05). The category of high-viscosity bulk-fill resin composites showed the significantly lowest polymerization shrinkage and force development. Within the tested flowable composite materials, SDR bulk-fill generated the significantly lowest shrinkage forces during polymerization and attained the significantly highest degree of conversion. Strong positive correlations were revealed between shrinkage force and both linear polymerization shrinkage (r = 0.902) and maximum force rate (r = 0.701). Linear shrinkage and shrinkage force both showed a negative correlation with filler volume content (r = - 0.832 and r = - 0.704, respectively). Bulk-fill resin composites develop lower shrinkage forces than their conventional flowable and high-viscosity counterparts, respectively, which supports their use for restoring high C-factor posterior cavities. Overall, bulk-fill composites with high filler amount and low force rate showed the most favorable shrinkage force characteristics
    • …
    corecore