16 research outputs found
Distal end of flexible bronchoscope using fiber reinforced soft actuator
Flexible bronchoscope (FOB) is a medical intervention instrument that provide distal end bending capability for inspecting respiratory airways. Although the use of the FOB is considered to be safe and easier, there are a major complication called pneumothorax which is a lesion on the surface of the respiratory airways that causes air leakage in the respiratory system due to the extreme movement o f the distal end of the FOB. The bronchoscopist must also manually rotate the whole body o f the flexible tube to do rotation movement. On the other side, research on fiber reinforced soft actuator (FRSA) becomes a prospective opportunity for development in medical devices and soft robotics. So, the objectives of this research are to develop a novel distal end o f the FOB prototype that minimize the risk of pneumothorax by providing local rotation in the novel distal end of the FOB and apply soft actuator mechanism in the development of distal end of the FOB. The concept of the system is a distal end of the FOB that provide smooth motion bend, soft material, and local rotation by using FRSA mechanism. A simulation was conducted using finite element analysis software which compared by type of fiber angles, fiber amount, and material. Prototype fabrication was also conducted using Rapid Prototyping Software and Computed Numerical Control Machine. The In-Vitro Experimental Setup consist of deformation angle measurement, bending force measurement, and functional testing using respiratory airways phantom. The testing result showed the prototype is able to bend 90° to the right, 89° to the left and 166° to rotate. The simulation and experiment similarity was 75.7% for right, 82.5% for the left, and 85.7% for the rotation. The maximum force that produced from the bending movement was 0.2 N which able to minimize the occurrence of pneumothorax. By in-vitro test, the prototype also able to inspect and manuver inside the respiratory airways
Pengembangan Fitur Keselamatan Mekanikal Blue Light Therapy Berbasis Motor Linear Terintegrasi
Pada perkembangan teknologi di era globalisasi saat ini dapat mempengaruhi terhadap suatu perkembangan peralatan, diantaranya yaitu peralatan rumah tangga, perkantoran, industri hingga peralatan kesehatan. Ketika ada sambaran petir dapat menghasilkan lonjakan tegangan listrik yang sangat besar, yang bisa merusak atau mempengaruhi perangkat elektronik. Pengembangan Fitur Keselamatan Mekanikal Blue Light Therapy Menggunakan Sensor Ultraviolet, Ultrasonik, Dan Motor Terintegrasi. Metode penelitian ini menggunakan metode prototype pada suatu alat. Studi Literatur yang berfungsi untuk mengumpulkan dan memahami beberapa referensi penelitian serta mendapatkan berbagai data dan informasi. Dalam penelitian ini, dilakukan pengembangan alat blue light therapy yang menggunakan sensor ultraviolet. Dalam pengembangan prototype pada sistem alat blue light therapy dengan fitur keselamatan menggunakan sensor guva s12sd (ultraviolet), ultrasonik, dan motor terintegrasi serta dirancang dalam bentuk box yang berwarna hitam dengan ukuran panjang 18,5 cm dan lebar 11,5 cm. Pada jarak 150 mm, dimmer di posisi 9 menghasilkan tegangan 198V dengan intensitas cahaya 4296,31 lux di LCD dan 4130 lux di luxmeter. Pada jarak 200 mm, posisi 9 menghasilkan 200,3V dengan 2148,44 lux di LCD dan 3080 lux di luxmeter. Sensor ultraviolet mengukur intensitas cahaya untuk memastikan bahwa paparan UV tetap dalam batas aman
AUTOMATIC LEAKAGE CURRENT MEASUREMENT METHOD AND THRESHOLD DECISION FEATURE OF IEC 62353:2014
Electrical safety testing is a very important activity to ensure safe operating standards for every product that uses electricity, especially medical devices. IEC 62353:2014 is used as standard for periodic and after repair testing on electromedical equipment. There are three methods, namely alternative methods, differential methods and direct methods. However, there are still many electromedical practitioners who have difficulty deciding which method will be used when conducting electrical safety testing on a certain medical device. Therefore, an automatic leakage current measurement method and threshold decision feature of IEC 62353:2014 is developed. The development is implementing the method decision flow chart in appendix of IEC 62353:2014 document in google spreadsheet platform
HOSPITAL BUILDING SAFETY: A SYSTEMATIC REVIEW
Safety is the most important aspect that needs to be considered in a hospital. There are several types of safety: patient safety, health personnel safety, building safety, equipment safety, green productivity, and hospital business safety. Building safety is determined to be the third common adverse event that occurred in hospital and affects directly to the safety of patients and health workers. Building safety in hospitals consists of electrical installations, fire and lightning protection, wastewater treatment plants, medical gas systems and medical vacuum, and elevator installation. A systematic review of problems and solutions to improve hospital building safety is expected to become a useful information for any health profession, engineers, and researchers. The purpose of this study is to identify the result of research on the implementation of building safety in the hospital. Some literature on adverse events and solutions from 2000-2019 was reviewed. The result shows various adverse events such as fall of the elevator, fire, damage electrical current which resulted in many victims. The result of this literature review can be a reference for hospitals to conduct evaluation and innovation in the implementation of building safety in hospitals
PEMELIHARAAN ALAT KESEHATAN PUSKESMAS REJOSARI
Puskesmas Rejosari adalah organisasi fungsional yang menyediakan layanan kesehatan kepada masyarakat di wilayah kerjanya, yang meliputi delapan kelurahan di Kecamatan Tenayan Raya, serta melayani pasien dari wilayah luar. Puskesmas ini diresmikan oleh Gubernur Riau pada 21 Juni 2017. Untuk meningkatkan layanan kesehatan pada tahun 2023, program studi Teknologi Rekayasa Elektromedis bekerja sama dengan DPD Ikatemi Riau dan IKTA melaksanakan kegiatan pengabdian masyarakat di Puskesmas Rejosari. Kegiatan ini meliputi pengecekan pemeliharaan dan kalibrasi alat kesehatan seperti sphygmomanometer, nebulizer, EKG, timbangan badan, dan sterilisator kering. Tujuan dari pengecekan ini adalah memastikan alat kesehatan dalam kondisi layak pakai, aman, dan berfungsi dengan baik untuk memberikan pelayanan optimal kepada pasien. Pemeliharaan preventif dilakukan sebelum kalibrasi, termasuk pembersihan, pemeriksaan fungsi, penyetelan, dan pelumasan alat kesehatan. Kegiatan ini tidak hanya meningkatkan kualitas pelayanan kesehatan di Puskesmas Rejosari, tetapi juga memberikan pengalaman praktis dan peningkatan kapasitas bagi dosen dan mahasiswa Institut Kesehatan dan Teknologi Al Insyirah dalam industri alat kesehatan.Puskesmas Rejosari adalah organisasi fungsional yang menyediakan layanan kesehatan kepada masyarakat di wilayah kerjanya, yang meliputi delapan kelurahan di Kecamatan Tenayan Raya, serta melayani pasien dari wilayah luar. Puskesmas ini diresmikan oleh Gubernur Riau pada 21 Juni 2017. Untuk meningkatkan layanan kesehatan pada tahun 2023, program studi Teknologi Rekayasa Elektromedis bekerja sama dengan DPD Ikatemi Riau dan IKTA melaksanakan kegiatan pengabdian masyarakat di Puskesmas Rejosari. Kegiatan ini meliputi pengecekan pemeliharaan dan kalibrasi alat kesehatan seperti sphygmomanometer, nebulizer, EKG, timbangan badan, dan sterilisator kering. Tujuan dari pengecekan ini adalah memastikan alat kesehatan dalam kondisi layak pakai, aman, dan berfungsi dengan baik untuk memberikan pelayanan optimal kepada pasien. Pemeliharaan preventif dilakukan sebelum kalibrasi, termasuk pembersihan, pemeriksaan fungsi, penyetelan, dan pelumasan alat kesehatan. Kegiatan ini tidak hanya meningkatkan kualitas pelayanan kesehatan di Puskesmas Rejosari, tetapi juga memberikan pengalaman praktis dan peningkatan kapasitas bagi dosen dan mahasiswa Institut Kesehatan dan Teknologi Al Insyirah dalam industri alat kesehatan
PELATIHAN INSPECTION PREVENTIVE MAINTENANCE ALAT SPECTROPHOTOMETER UV-VIS UNTUK TEKNISI ELEKTROMEDIS DI PROVINSI RIAU
Abstract. Uv-Vis Spectrophotometer is one of the instruments in the hospital located in the clinical laboratory where its management is under the responsibility of the Electromedical Technician. The medical device technology development has led to adjustments and developments in managing the Uv-Vis spectrophotometer. The purpose of this service activity is to provide Inspection Preventive Maintainance (IPM) training for Uv-Vis spectrophotometer equipment and share developments in Uv-Vis spectrophotometer technology with electromedical technicians. With this, hospitals can provide complete services to the community. The training was held on March 26, 2022, using the Zoom Meeting media and was attended by 401 participants from all over Indonesia. Participants were given a pretest and posttest to determine the level of participants abilities with this training. Before the training, the ability of the participants was 60.30% while after the training the ability of the participants was 78.55% so there was an increase in the ability of the participants by 18.25%. The average level of participant satisfaction with this training activity is 85.54%, which is in the very satisfactory category Abstrak. Spektrofotometer Uv-Vis merupakan salah satu alat di rumah sakit yang berada pada laboratorium klinik dimana pengelolaannya di bawah tanggung jawab Teknisi Elektromedis. Perkembangan teknologi alat kesehatan menyebabkan adanya penyesuaian dan perkembangan terhadap pengelolaan alat spektrofotometer Uv-Vis. Tujuan dari kegiatan pengabdian ini adalah memberikan pelatihan Inspection Preventive Maintainance (IPM) peralatan spektrofotometer Uv-Vis dan sharing perkembangan teknologi spektrofotometer Uv-Vis kepada teknisi elektromedis. Dengan hal itu, rumah sakit dapat memberikan pelayanan yang paripurna kepada masyarakat. Pelatihan dilaksanakan pada tanggal 26 maret 2022 menggunakan media Zoom Meeting dan diikuti oleh 401 peserta dari seluruh Indonesia. Peserta diberikan pretest dan postest unutk mengetahui tingkat kemampuan peserta dengan adanya pelatihan ini. Sebelum pelatihan kemampuan peserta sebesar 60,30% sedangkan setelah pelatihan kemampuan peserta sebesar 78,55% sehingga terjadi peningkatan kemampuan peserta sebesar 18,25%. Adapun rata-rata tingkat kepuasan peserta terhadap kegiatan pelatihan ini adalah 85,54% berada pada kategori sangat memuaskan.
ANALYSIS INFUSION PUMP CALIBRATION RESULTS MERK TERUMO TYPE TE-112
The infusion pump functions to periodically control and regulate the administration of substances that are liquid nutrients or drugs at the right dose into the patient's body in a certain amount through the blood vessels with moderate precision. The use of an infusion pump for a long time will affect the accuracy and accuracy of the tool, which can result in compression and thus disrupt the flow rate regulation. For this reason, the Infusion Pump must be calibrated periodically. Infusion Pump calibration is carried out using a direct measurement method by testing the parameters of the physical condition and function of the tool, measuring electrical safety and its flow rate. Based on the results of the research and analysis of the calculation of the uncertainty of the measurement, the parameters of the physical condition and function of the tool as well as the electrical safety are in 100% good condition, while the flow rate parameter is in a condition of 66.67%. After reviewing the calibration results of the three parameters, the total value was 83.33%. So that the Infusion Pump tool is in a USAGE-worthy status
STUDI REKOMENDASI PENGHAPUSAN ALAT KESEHATAN DENGAN MENGGUNAKAN METODE ANALISIS BIAYA DI RSUD ARIFIN AHMAD KOTA PEKANBARU
Penumpukan alat kesehatan yang sudah tidak layak pakai lagi menjadi suatu permasalahan di rumah sakit karena bisa memenuhi ruangan gudang dan jika tidak dihapuskan maka akan terjadi penambahan ruangan untuk alat kesehatan yang sudah rusak serta bisa mengakibatkan pencemaran lingkungan. Penelitian ini untuk studi rekomendasi penghapusan alat kesehatan dengan metode analisi biaya kota pekanbaru di harapkan penelitian ini bisa membantu teknisi dan rumah sakit dalam melakukan penghapusan alat kesehatan, jenis penelitian ini adalah penelitian kualitatif dan kuantitatif. Dari hasil penelitian dapat disimpulkan bahwa terdapat 2 jenis kendala dalam penghapusan alat kesehatan di RSUD Arifin Ahmad yaitu kendala dari pihak luar maupun dari dalam. Untuk kendala dari pihak luar seperti KPKNL (kantor pelayanan kekayaan Negara dan lelang), pihak KPKNL dengan sumber daya manusia yang terbatas menjadi kendala dalam hal lelang dikarenakan pihak KPKNL memiliki jadwal yang sangat padat jadi RSUD harus menunggu jadwalnya fungsi dari KPKNL yaitu menetapkan harga alat kesehatan yang akan dilelang, Sedangkan kendala didalam RSUD sulitnya mengurus surat penghapusan ke gubernur serta izin surat dari BPOM, BAPETEN dan sebagainya serta terkendala dalam sumber daya manusia di bagian logistik sebab alat kesehatan yang rusak RSUD sebanyak 1000 lebih sehingga harus membentuk tim yang besar dalam penghapusan alat sebanyak ini, jadi solusinya memperbaiki sistem dari masing-masing pihak dengan menambah sumber daya manusia mengadakan pelatihan keterampilan, memberikan edukasi, mengadakan pembinaan dikarenakan untuk melakukan penghapusan dengan jumlah alat yang sampai ribuan memerlukan tim yang sangat besar dengan konsekuensi menambah biaya pengeluaran dan menggunakan metode lelang atau penjualan ke perusahaan yang akan menguntungkan pihak rumah sakit.
Braided angle soft actuator for flexible bronchoscopy tip: design, simulation, and manufacture
This paper presents a new design of braided angle soft actuator for flexible bronchoscopy tip, which combines twisting and bending motions of soft actuator. This study is focused on the design, simulation and manufacture stages. The soft actuator was designed to fit with the anatomy of human bronchial tree for inspection purpose. The simulation of the design was done to verify the best structure for producing the functional requirement. The fabrication of the soft actuator utilized a molding system. From the gradient value of linear regression analysis, it demonstrated that the proposed soft-tip is capable of moving close to the functional requirement after standard pressure driving experiment was executed
A Novel Design of Needle Aspiration Biopsy Monitoring Instrument (NAOMI) Tested on a Low Cost Chest Phantom
Needle biopsy is a medical intervention method for taking a lung tissue sample that suspected as a cancer. The disadvantage is the physicians directly visualize the anatomical structures in an open surgery for lung cancer biopsy procedure. There is a need to develop an instrument that may help the physician to guarantee the accuracy and efficiency while performing needle aspiration biopsy. Therefore, a needle aspiration biopsy monitoring instrument or named as NAOMI is proposed. It consists of a microcontroller system, an IMU sensor, an ultrasonic ranging module, a bluetooth module, and a 9V lithium battery. The experimental testing consist of performance testing, functional testing using chest phantom, and user acceptances. The results showed that the NAOMI improve the accuracy and efficiency while performing the needle biopsy operation