    CLIC e+e- Linear Collider Studies - Input to the Snowmass process 2013

    Full text link
    This paper addresses the issues in question for Energy Frontier Lepton and Gamma Colliders by the Frontier Capabilities group of the Snowmass 2013 process and is structured accordingly. It will be accompanied by a paper describing the Detector and Physics studies for the CLIC project currently in preparation for submission to the Energy Frontier group.Comment: Submitted to the Snowmass process 2013. arXiv admin note: substantial text overlap with arXiv:1208.140

    Machine Parameters and Projected Luminosity Performance of Proposed Future Colliders at CERN

    Full text link
    In response to a request from the CERN Scientific Policy Committee (SPC), the machine parameters and expected luminosity performance for several proposed post-LHC collider projects at CERN are compiled: three types of hadron colliders (HL-LHC upgrade, FCC-hh and HE-LHC), a circular lepton collider (FCC-ee), a linear lepton collider (CLIC), and three options for lepton-hadron colliders (LHeC, HE-LHeC, and FCC-eh). Particular emphasis is put on availability, physics run time, and efficiency. The information contained in this document was presented at the SPC Meeting of September 2018. It will serve as one of the inputs to the 2019/20 Update of the European Strategy for Particle Physics

    CLIC e+e- Linear Collider Studies

    Full text link
    This document provides input from the CLIC e+e- linear collider studies to the update process of the European Strategy for Particle Physics. It is submitted on behalf of the CLIC/CTF3 collaboration and the CLIC physics and detector study. It describes the exploration of fundamental questions in particle physics at the energy frontier with a future TeV-scale e+e- linear collider based on the Compact Linear Collider (CLIC) two-beam acceleration technique. A high-luminosity high-energy e+e- collider allows for the exploration of Standard Model physics, such as precise measurements of the Higgs, top and gauge sectors, as well as for a multitude of searches for New Physics, either through direct discovery or indirectly, via high-precision observables. Given the current state of knowledge, following the observation of a \sim125 GeV Higgs-like particle at the LHC, and pending further LHC results at 8 TeV and 14 TeV, a linear e+e- collider built and operated in centre-of-mass energy stages from a few-hundred GeV up to a few TeV will be an ideal physics exploration tool, complementing the LHC. Two example scenarios are presented for a CLIC accelerator built in three main stages of 500 GeV, 1.4 (1.5) TeV, and 3 TeV, together with the layout and performance of the experiments and accompanied by cost estimates. The resulting CLIC physics potential and measurement precisions are illustrated through detector simulations under realistic beam conditions.Comment: Submitted to the European Strategy Preparatory Grou

    The Compact Linear Collider (CLIC) - 2018 Summary Report

    Get PDF
    The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear e+e- collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years

    A scalable data taking system at a test beam for LHC

    Get PDF
    We propose the installation of a data taking system at a test beam for the simultaneous test of LHC detectors, trigger and readout electronics, together with the development of the supporting architecture in a multiprocessor environment. A strong emphasis is put on a highly modular design, such that new hardware and software developments can be conveniently introduced for training and evaluation. One of the main thrusts of the project will be the modelling and system integration of different readout architectures, which are meant to provide a valuable training ground for new techniques. To address these aspects in a realistic manner, we propose to collaborate with two detector R+D projects

    Development of fluorocarbon evaporative cooling recirculators and controls for the ATLAS inner silicon tracker

    Get PDF
    We report on the development of evaporative fluorocarbon cooling recirculators and their control systems for the ATLAS inner silicon tracker. We have developed a prototype circulator using a dry, hermetic compressor with C/sub 3/F/sup 8/ refrigerant, and have prototyped the remote-control analog pneumatic links for the regulation of coolant mass flows and operating temperatures that will be necessary in the magnetic field and radiation environment around ATLAS. pressure and flow measurement and control use 150+ channels of standard ATLAS LMB ("Local Monitor Board") DAQ and DACs on a multi-drop CAN network administered through a BridgeVIEW user interface. A hardwired thermal interlock system has been developed to cut power to individual silicon modules should their temperatures exceed safe values. Highly satisfactory performance of the circulator under steady state, partial-load and transient conditions was seen, with proportional fluid flow tuned to varying circuit power. Future developments, including a 6 kW demonstrator with ~25 cooling circuits, are outlined

    AX-PET: A novel PET concept with G-APD readout

    Get PDF
    Abstract The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 keV and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS strips are individually read out using Geiger-mode Avalanche Photo Diodes (G-APDs). The sensitivity of such a detector can be adjusted by changing the number of layers and the resolution is defined by the crystal and strip dimensions. Two AX-PET modules were built and fully characterized in dedicated test set-ups at CERN, with point-like 22 Na sources. Their performance in terms of energy ( R energy ≈ 11.8 % (FWMH) at 511 keV) and spatial resolution was assessed ( σ axial ≈ 0.65 mm ), both individually and for the two modules in coincidence. Test campaigns at ETH Zurich and at the company AAA allowed the tomographic reconstructions of more complex phantoms validating the 3D reconstruction algorithms. The concept of the AX-PET modules will be presented together with some characterization results. We describe a count rate model which allows to optimize the planing of the tomographic scans