5,257 research outputs found
Chemiluminescent Tags for Tracking Insect Movement in Darkness: Application to Moth Photo-Orientation
The flight tracks of Manduca sexta (Lepidoptera: Sphingidae) flying toward a 5 watt incandescent light bulb were recorded under low light conditions with the aid of a camera-mounted photomultiplier and a glowing marker technique. Small felt pads bearing a chemiluminescent (glowi maerial, Cyalume®, were affixed to the abdomens of free-flying moths. insects orienting to a dim incandescent bulb were easily visible to the naked eye and were clearly captured on videotape. On their initial approach to the light source, M. sexta were found to orient at a mean angle of -0.220 ± 2.70 (mean ± SEM). The speed of the initial approach flight (OA ± 0.03 m/s) was significantly faster than the speed immediately after passing the light (0.29 ± 0.02 m/s; t =6.4, PM. sexta initially fly approximately at a light source and only after passing it, do they engage in circular flight around the source. M. sexta flight to lights does not entirely match any paths predicted by several light orientation mechanisms, including the commonly invoked light compass theory
Electrical switching in a magnetically intercalated transition metal dichalcogenide.
Advances in controlling the correlated behaviour of transition metal dichalcogenides have opened a new frontier of many-body physics in two dimensions. A field where these materials have yet to make a deep impact is antiferromagnetic spintronics-a relatively new research direction promising technologies with fast switching times, insensitivity to magnetic perturbations and reduced cross-talk1-3. Here, we present measurements on the intercalated transition metal dichalcogenide Fe1/3NbS2 that exhibits antiferromagnetic ordering below 42 K (refs. 4,5). We find that remarkably low current densities of the order of 104 A cm-2 can reorient the magnetic order, which can be detected through changes in the sample resistance, demonstrating its use as an electronically accessible antiferromagnetic switch. Fe1/3NbS2 is part of a larger family of magnetically intercalated transition metal dichalcogenides, some of which may exhibit switching at room temperature, forming a platform from which to build tuneable antiferromagnetic spintronic devices6,7
Direct estimation of cause-specific mortality fractions from verbal autopsies: multisite validation study using clinical diagnostic gold standards
Abstract Background Verbal autopsy (VA) is used to estimate the causes of death in areas with incomplete vital registration systems. The King and Lu method (KL) for direct estimation of cause-specific mortality fractions (CSMFs) from VA studies is an analysis technique that estimates CSMFs in a population without predicting individual-level cause of death as an intermediate step. In previous studies, KL has shown promise as an alternative to physician-certified verbal autopsy (PCVA). However, it has previously been impossible to validate KL with a large dataset of VAs for which the underlying cause of death is known to meet rigorous clinical diagnostic criteria. Methods We applied the KL method to adult, child, and neonatal VA datasets from the Population Health Metrics Research Consortium gold standard verbal autopsy validation study, a multisite sample of 12,542 VAs where gold standard cause of death was established using strict clinical diagnostic criteria. To emulate real-world populations with varying CSMFs, we evaluated the KL estimations for 500 different test datasets of varying cause distribution. We assessed the quality of these estimates in terms of CSMF accuracy as well as linear regression and compared this with the results of PCVA. Results KL performance is similar to PCVA in terms of CSMF accuracy, attaining values of 0.669, 0.698, and 0.795 for adult, child, and neonatal age groups, respectively, when health care experience (HCE) items were included. We found that the length of the cause list has a dramatic effect on KL estimation quality, with CSMF accuracy decreasing substantially as the length of the cause list increases. We found that KL is not reliant on HCE the way PCVA is, and without HCE, KL outperforms PCVA for all age groups. Conclusions Like all computer methods for VA analysis, KL is faster and cheaper than PCVA. Since it is a direct estimation technique, though, it does not produce individual-level predictions. KL estimates are of similar quality to PCVA and slightly better in most cases. Compared to other recently developed methods, however, KL would only be the preferred technique when the cause list is short and individual-level predictions are not needed.</p
Retro-biosynthetic screening of a modular pathway design achieves selective route for microbial synthesis of 4-methyl-pentanol
Increasingly complex metabolic pathways have been engineered by modifying natural pathways and establishing de novo pathways with enzymes from a variety of organisms. Here we apply retro-biosynthetic screening to a modular pathway design to identify a redox neutral, theoretically high yielding route to a branched C6 alcohol. Enzymes capable of converting natural E. coli metabolites into 4-methyl-pentanol (4MP) via coenzyme A (CoA)-dependent chemistry were taken from nine different organisms to form a ten-step de novo pathway. Selectivity for 4MP is enhanced through the use of key enzymes acting on acyl-CoA intermediates, a carboxylic acid reductase from Nocardia iowensis and an alcohol dehydrogenase from Leifsonia sp. strain S749. One implementation of the full pathway from glucose demonstrates selective carbon chain extension and acid reduction with 4MP constituting 81% (90±7 mg l⁻¹) of the observed alcohol products. The highest observed 4MP titre is 192±23 mg l⁻¹. These results demonstrate the ability of modular pathway screening to facilitate de novo pathway engineering.United States. Army Research Office (W911NF-09-0001
Bostonia. Volume 4
Founded in 1900, Bostonia magazine is Boston University's main alumni publication, which covers alumni and student life, as well as university activities, events, and programs
Yang-Mills gravity in biconformal space
We write a gravity theory with Yang-Mills type action using the biconformal
gauging of the conformal group. We show that the resulting biconformal
Yang-Mills gravity theories describe 4-dim, scale-invariant general relativity
in the case of slowly changing fields. In addition, we systematically extend
arbitrary 4-dim Yang-Mills theories to biconformal space, providing a new arena
for studying flat space Yang-Mills theories. By applying the biconformal
extension to a 4-dim pure Yang-Mills theory with conformal symmetry, we
establish a 1-1, onto mapping between a set of gravitational gauge theories and
4-dim, flat space gauge theories.Comment: 27 pages; paper emphasis shifted to focus on gravity; references
adde
Centerscope
Centerscope, formerly Scope, was published by the Boston University Medical Center "to communicate the concern of the Medical Center for the development and maintenance of improved health care in contemporary society.
Demonstration of a switchable damping system to allow low-noise operation of high-Q low-mass suspension systems
Low mass suspension systems with high-Q pendulum stages are used to enable
quantum radiation pressure noise limited experiments. Utilising multiple
pendulum stages with vertical blade springs and materials with high quality
factors provides attenuation of seismic and thermal noise, however damping of
these high-Q pendulum systems in multiple degrees of freedom is essential for
practical implementation. Viscous damping such as eddy-current damping can be
employed but introduces displacement noise from force noise due to thermal
fluctuations in the damping system. In this paper we demonstrate a passive
damping system with adjustable damping strength as a solution for this problem
that can be used for low mass suspension systems without adding additional
displacement noise in science mode. We show a reduction of the damping factor
by a factor of 8 on a test suspension and provide a general optimisation for
this system.Comment: 5 pages, 5 figure
The SKA Particle Array Prototype: The First Particle Detector at the Murchison Radio-astronomy Observatory
We report on the design, deployment, and first results from a scintillation
detector deployed at the Murchison Radio-astronomy Observatory (MRO). The
detector is a prototype for a larger array -- the Square Kilometre Array
Particle Array (SKAPA) -- planned to allow the radio-detection of cosmic rays
with the Murchison Widefield Array and the low-frequency component of the
Square Kilometre Array. The prototype design has been driven by stringent
limits on radio emissions at the MRO, and to ensure survivability in a desert
environment. Using data taken from Nov.\ 2018 to Feb.\ 2019, we characterize
the detector response while accounting for the effects of temperature
fluctuations, and calibrate the sensitivity of the prototype detector to
through-going muons. This verifies the feasibility of cosmic ray detection at
the MRO. We then estimate the required parameters of a planned array of eight
such detectors to be used to trigger radio observations by the Murchison
Widefield Array.Comment: 17 pages, 14 figures, 3 table
- …
