318,008 research outputs found
Photovoltaics as a terrestrial energy source. Volume 2: System value
Assumptions and techniques employed by the electric utility industry and other electricity planners to make estimates of the future value of photovoltaic (PV) systems interconnected with U.S. electric utilities were examined. Existing estimates of PV value and their interpretation and limitations are discussed. PV value is defined as the marginal private savings accruing to potential PV owners. For utility-owned PV systems, these values are shown to be the after-tax savings in conventional fuel and capacity displaced by the PV output. For non-utility-owned (distributed) systems, the utility's savings in fuel and capacity must first be translated through the electric rate structure (prices) to the potential PV system owner. Base-case estimates of the average value of PV systems to U.S. utilities are presented. The relationship of these results to the PV Program price goals and current energy policy is discussed; the usefulness of PV output quantity goals is also reviewed
Magnetohydrodynamic power generation
Magnetohydrodynamic (MHD) Power Generation is a concise summary of MHD theory, history, and future trends. Results of the major international MHD research projects are discussed. Data from MHD research is included. Economics of initial and operating costs are considered
Analysis of Full-Test tools and their limitations as applied to terminal junction blocks
Discovery of unlocked contacts in Deutsch Block terminal junctions in Solid Rocket Booster flight hardware prompted an investigation into pull test techniques to help insure against possible failures. Internal frictional forces between socket and pin and between wire and grommet were examined. Pull test force must be greater than internal friction yet less than the crimp strength of the pin or socket. For this reason, a 100 percent accurate test is impossible. Test tools were evaluated. Available tools are adequate for pull testing
Development of a simplified optical technique for the simultaneous measurement of particle size distribution and velocity
Existing techniques were surveyed, an experimental procedure was developed, a laboratory test model was fabricated, limited data were recovered for proof of principle, and the relationship between particle size distribution and amplitude measurements was illustrated in an effort to develop a low cost, simplified optical technique for measuring particle size distributions and velocities in fluidized bed combustors and gasifiers. A He-Ne laser illuminated Rochi Rulings (range 10 to 500 lines per inch). Various samples of known particle size distributions were passed through the fringe pattern produced by the rulings. A photomultiplier tube converted light from the fringe volume to an electrical signal which was recorded using an oscilloscope and camera. The signal amplitudes were correlated against the known particle size distributions. The correlation holds true for various samples
Domain State Occurring in the de Haas-van Alphen Effect in Silver
Hysteresis has been observed in de Haas-van Alphen measurements of the Condon
domains in silver, and it shows the first-order nature of the transition to the
domain state. The hysteresis, and thus the first-order nature, is manifested in
a nonlinear effect where a double-valued response of the amplitude with the
applied external field is observed
Historical evidence of importance to the industrialization of flat-plate silicon photovoltaic systems. Volume 1: Executive summary
An analysis is given of the Low-Cost Silicon Solar Array Project plans for the industrialization of new production technologies expected to be forthcoming as a result of the project's technology development efforts. In particular, LSSA's mandate to insure an annual production capability of 500 MW peak for the photovoltaic supply industry by 1986 is critically examined. The examination focuses on one of the concerns behind this goal -- timely development of industrial capacity to supply anticipated demand. Some of the conclusions include: (1) construction of small-scale pilot plants should be undertaken only for purposes of technology development; (2) large-scale demonstrations should be undertaken only when the technology is well in hand; (3) commercial-scale production should be left to the private sector; (4) the 500-MW annual output goal should be shifted to Program Headquarters
Adherence to prophylaxis in adolescents and young adults with severe haemophilia, A qualitative study with patients
© 2018 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.Abstract Introduction: Reported levels of adherence to prophylaxis among young people with haemophilia (YPH) vary widely and are predominately based on estimations made by healthcare professionals and parents. Reasons for (non)adherence among YPH in particular have not been evidenced. Aim: to examine experiences in relation to prophylaxis with YPH themselves, and barriers and facilitators to their adherence. Methods: 11 Participants were recruited in five haemophilia centres across England and Wales. All patients who met the inclusion criteria (aged 12-25, diagnosed with haemophilia, on prophylaxis) were approached during a routine check-up appointment, and all participants who agreed to take part were interviewed. Interviews were audio recorded, transcribed and analysed using Interpretative Phenomenological Analysis. Results: Self-reported adherence to prophylaxis was good. Few participants admitted to intentionally skipping injections although they reported sometimes forgetting. However, due to the increasingly personalised and flexible approach to prophylaxis, adherence is not straightforward to define. Barriers to adherence included a busy lifestyle, dislike of the intravenous injection, venous access issues, anxiety or stress and being out of one’s normal routine. Support was an important facilitator to adherence, including support from health professionals at the haemophilia centre as well as friends. Parents appear to be very involved with their sons’ haemophilia management, even after their sons leave home. Conclusion: What this study adds is that the increasingly flexible and personalized approach to managing prophylaxis in haemophilia may sometimes lead to confusion around treatment frequency and dosing. This may lead to accidental non-adherence, which is distinct from both skipping and forgetting. Advice from haemophilia teams may not always be consistent, and is likely to be interpreted differently by different individuals. Some additional training and education of patients and their families to increase their knowledge and skills around prophylaxis may reduce this confusion and therefore is likely to improve adherence further.Peer reviewedFinal Published versio
A New Approach to Fibrous Composite Laminate Strength Prediction
A method of predicting the strength of cross-plied fibrous composite laminates is based on expressing the classical maximum-shear-stress failure criterion for ductile metals in terms of strains. Starting with such a formulation for classical isotropic materials, the derivation is extended to orthotropic materials having a longitudinal axis of symmetry, to represent the fibers in a unidirectional composite lamina. The only modification needed to represent those same fibers with properties normalized to the lamina rather than fiber is a change in axial modulus. A mirror image is added to the strain-based lamina failure criterion for fiber-dominated failures to reflect the cutoffs due to the presence of orthogonal fibers. It is found that the combined failure envelope is now identical with the well-known maximum-strain failure model in the tension-tension and compression-compression quadrants but is truncated in the shear quadrants. The successive application of this simple failure model for fibers in the 0/90 degree and +/- 45 degree orientations, in turn, is shown to be the necessary and sufficient characterization of the fiber-dominated failures of laminates made from fibers having the same tensile and compressive strengths. When one such strength is greater than the other, the failure envelope is appropriately truncated for the lesser direct strain. The shear-failure cutoffs are now based on the higher axial strain to failure since they occur at lower strains than and are usually not affected by such mechanisms as microbuckling. Premature matrix failures can also be covered by appropriately truncating the fiber failure envelope. Matrix failures are excluded from consideration for conventional fiber/polymer composites but the additional features needed for a more rigorous analysis of exotic materials are covered. The new failure envelope is compared with published biaxial test data. The theory is developed for unnotched laminates but is easily shrunk to incorporate reductions to allow for bolt holes, cutouts, reduced compressive strength after impact, and the like
- …