2,026 research outputs found
Resonances and Exclusive Channels: an Experimenter's Summary
A very remarkable number of new results in the study of resonances and
exclusive channels has been presented at this conference giving fundamental
information in the understanding of strong interactions at low energies. The
first results from the new high luminosity colliders are impressive and a lot
of activity in this field is foreseen for the future. The most relevant issues
are summarized and discussed in this paper.Comment: Talk given at PHOTON 2001, Ascona, Switzerland, September 200
Exclusive Channels in Photon-Photon Collisions at LEP
The study of exclusive channels in photon-photon collisions at e+e- colliders
allows to investigate the structure and the properties of hadrons in a very
clean experimental environment. A concise review of the most recent results
obtained at LEP is presented.Comment: Talk given at XXVIIth Rencontres de Moriond Les Arcs, France, March,
200
Present challenges in hadrontherapy techniques
Hadrontherapy is a high-precision technique in cancer radiation therapy, which allows obtaining a superior conformal treatment with respect to photons used in conventional radiation therapy. To reach this ambitious goal without reducing the patient throughput needed in a hospital-based environment, the physical and radiobiological properties of charged hadrons, protons and carbon ions in particular, have to be exploited at best, making use of the most modern technologies issued from research in nuclear and particle physics. In the present days, we are assisting to a continuous technological challenge, leading to the conception and to the development of innovative methods and instruments. In this paper, the most relevant challenges in dose delivery systems, gantries, imaging, quality assurance and particle accelerators are reviewe
Study of the Final State and the Inclusive Production in Two-Photon Collisions with the L3 Detector at LEP
The KK final state in two-photon collisions is studied with the L3 detector at LEP using data collected at centre of mass energies from 91 GeV to 202 GeV. The mass spectrum is dominated by the formation of the f(1525) tensor meson in helicity two state. Clear evidence for destructive f-a interference is observed. The first study of the f(1710) in two-photon collisions is presented. No signal has been observed in the region around 2.2 GeV and an upper limit for the two-photon partial width of the (2220) glueball candidate is derived. In the reaction \epem\rightarrow\epemhadrons the inclusive production of \kos mesons is studied using data collected by the L3 detector at LEP centre of mass energies from 189 to 202 GeV. The differential production cross sections as a function of the transverse momentum and of the pseudorapidity are measured and a reasonable agreement is found between our measurement and the Next-to-Leading order QCD predictions
A system for online beam emittance measurements and proton beam characterization
A system for online measurement of the transverse beam emittance was
developed. It is named PrOBaM (4-Profiler Online Beam
Emittance Measurement) and was conceived to measure the emittance in a fast and
efficient way using the multiple beam profiler method. The core of the system
is constituted by four consecutive UniBEaM profilers, which are based on silica
fibers passing across the beam. The PrOBaM system was
deployed for characterization studies of the 18~MeV proton beam produced by the
IBA Cyclone 18 MeV cyclotron at Bern University Hospital (Inselspital). The
machine serves daily radioisotope production and multi-disciplinary research,
which is carried out with a specifically conceived Beam Transport Line (BTL).
The transverse RMS beam emittance of the cyclotron was measured as a function
of several machine parameters, such as the magnetic field, RF peak voltage, and
azimuthal angle of the stripper. The beam emittance was also measured using the
method based on the quadrupole strength variation. The results obtained with
both techniques were compared and a good agreement was found. In order to
characterize the longitudinal dynamics, the proton energy distribution was
measured. For this purpose, a method was developed based on aluminum absorbers
of different thicknesses, a UniBEaM detector, and a Faraday cup. The results
were an input for a simulation of the BTL developed in the MAD-X software. This
tool allows machine parameters to be tuned online and the beam characteristics
to be optimized for specific applications.Comment: published in Journal of Instrumentatio
An adjustable focusing system for a 2 MeV H- ion beam line based on permanent magnet quadrupoles
A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed,
constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ
model is realised using finite element simulations, providing an integrated
field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype
is constructed and the magnetic field is measured, demonstrating good agreement
with the simulation. Particle track simulations provide initial values for the
quadrupole positions. Accordingly, four PMQs are constructed and assembled on
the beam line, their positions are then tuned to obtain a minimal beam spot
size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam
line for an external ion beam. The novel compact design based on commercially
available NdFeB magnets allows high flexibility for ion beam applications.Comment: published in JINST (4th Feb 2013
Magnetic field dependence of vortex activation energy: a comparison between MgB2, NbSe2 and Bi2Sr2Ca2Cu3O10 superconductors
The dissipative mechanism at low current density is compared in three
different classes of superconductors. This is achieved by measurement of
resistance as a function of temperature and magnetic field in clean
polycrystalline samples of NbSe2, MgB2 and Bi2Sr2Ca2Cu3O10 superconductors.
Thermally activated flux flow behavior is clearly identified in bulk MgB2.
While the activation energy at low fields for MgB2 is comparable to
Bi2Sr2Ca2Cu3O10, its field dependence follows a parabolic behavior unlike a
power law dependence seen in Bi2Sr2Ca2Cu3O10. We analyze our results based on
the Kramer's scaling for grain boundary pinning in MgB2and NbSe2
Significant enhancement of irreversibility field in clean-limit bulk MgB2
Low resistivity ("clean") MgB2 bulk samples annealed in Mg vapor show an
increase in upper critical field Hc2(T) and irreversibility field Hirr(T) by a
factor of 2 in both transport and magnetic measurements. The best sample
displayed Hirr above 14 T at 4.2 K and 6 T at 20 K. These changes were
accompanied by an increase of the 40 K resistivity from 1.0 to 18 microohm-cm
and a lowering of the resistivity ratio from 15 to 3, while the critical
temperature Tc decreased by only 1-2 K. These results point the way to make
prepare MgB2 attractive for magnet applications.Comment: 3 pages, 4 figures, submitted to Applied Physics Letter
Highly effective and isotropic pinning in epitaxial Fe(Se,Te) thin films grown on CaF2 substrates
We report on the isotropic pinning obtained in epitaxial Fe(Se,Te) thin films
grown on CaF2 (001) substrate. High critical current density values larger than
1 MA/cm2 in self field in liquid helium are reached together with a very weak
dependence on the magnetic field and a complete isotropy. Analysis through
Transmission Electron Microscopy evidences the presence of defects looking like
lattice disorder at a very small scale, between 5 and 20 nm, which are thought
to be responsible for such isotropic behavior in contrast to what observed on
SrTiO3, where defects parallel to the c-axis enhance pinning in that directio
Parameters of scalar resonances from the combined analysis of data on processes and decays
A combined analysis of data on isoscalar S-wave processes
and on decays
from the DM2, Mark III and BESIII
collaborations is performed to study mesons. The method of analysis is
based on analyticity and unitarity and uses an uniformization procedure. In the
analysis limited only to the multi-channel -scattering data, two
possible sets of parameters of the were found: in both cases the
mass was about 700 MeV but the total width was either about 600 or 930 MeV. The
extension of the analysis using only the DM2 and Mark III data on the
decays does not allow to choose between these sets. However, the data from
BESIII on the di-pion mass distribution in the decay
clearly prefers the wider state. Spectroscopic implications from
results of the analysis are also discussed.Comment: the formalism is also described (text overlap) in arXiv:1108.3725;
new extended analysis of data; revised PRD versio
- …
