204 research outputs found

    Rebuilding vascular access: from the viewpoint of mechanics and materials

    Get PDF
    This review presents a comprehensive analysis of vascular access in hemodialysis, focusing on the current modalities, their associated challenges, and recent technological advancements. It closely examines the status of three primary types of vascular access: arteriovenous fistulas, arteriovenous grafts, and central venous catheters. The review delves into the complications and pathologies associated with these access types, emphasizing the mechanobiology-related pathogenesis of arteriovenous access. Furthermore, it explores recent clinical trials, biomaterials, and device innovations, highlighting novel pharmaceutical approaches, advanced materials, device designs, and cutting-edge technologies aimed at enhancing the efficacy, safety, and longevity of vascular access in hemodialysis. This synthesis of current knowledge and emerging trends underscores the dynamic evolution of vascular access strategies and their critical role in improving patient care in hemodialysis

    Donor‐Derived Engineered Microvessels for Cardiovascular Risk Stratification of Patients with Kidney Failure

    Get PDF
    Cardiovascular disease is the cause of death in ≈50% of hemodialysis patients. Accumulation of uremic solutes in systemic circulation is thought to be a key driver of the endothelial dysfunction that underlies elevated cardiovascular events. A challenge in understanding the mechanisms relating chronic kidney disease to cardiovascular disease is the lack of in vitro models that allow screening of the effects of the uremic environment on the endothelium. Here, a method is described for microfabrication of human blood vessels from donor cells and perfused with donor serum. The resulting donor-derived microvessels are used to quantify vascular permeability, a hallmark of endothelial dysfunction, in response to serum spiked with pathophysiological levels of indoxyl sulfate, and in response to serum from patients with chronic kidney disease and from uremic pigs. The uremic environment has pronounced effects on microvascular integrity as demonstrated by irregular cell-cell junctions and increased permeability in comparison to cell culture media and healthy serum. Moreover, the engineered microvessels demonstrate an increase in sensitivity compared to traditional 2D assays. Thus, the devices and the methods presented here have the potential to be utilized to risk stratify and to direct personalized treatments for patients with chronic kidney disease

    Toward Patient-Centered Innovation: A Conceptual Framework for Patient-Reported Outcome Measures for Transformative Kidney Replacement Devices

    Get PDF
    Individuals with dialysis-dependent kidney failure experience considerable disease- and treatment-related decline in functional status and overall well-being. Despite these experiences, there have been few substantive technological advances in KRT in decades. As such, new federal initiatives seek to accelerate innovation. Historically, integration of patient perspectives into KRT product development has been limited. However, the US Food and Drug Administration recognizes the importance of incorporating patient perspectives into the total product life cycle (i.e., from product conception to postmarket surveillance) and encourages the consideration of patient-reported outcomes in regulatory-focused clinical trials when appropriate. Recognizing the significance of identifying patient-reported outcome measures (PROMs) that capture contemporary patient priorities, the Kidney Health Initiative, a public-private partnership between the American Society of Nephrology and US Food and Drug Administration, convened a workgroup to (1) develop a conceptual framework for a health-related quality of life PROM; (2) identify and map existing PROMs to the conceptual framework, prioritizing them on the basis of their supporting evidence for use in the regulatory environment; and (3) describe next steps for identifying PROMs for use in regulatory clinical trials of transformative KRT devices. This paper summarizes the proposed health-related quality-of-life PROM conceptual framework, maps and prioritizes PROMs, and identifies gaps and future needs to advance the development of rigorous, meaningful PROMS for use in clinical trials of transformative KRT devices

    Association of Bradycardia and Asystole Episodes with Dialytic Parameters: An Analysis of the Monitoring in Dialysis (MiD) Study

    Get PDF
    BACKGROUND: Bradycardia and asystole events are common among patients treated with maintenance hemodialysis. However, triggers of these events in patients on maintenance hemodialysis (HD), particularly during the long interdialytic period when these events cluster, are uncertain. METHODS: The Monitoring in Dialysis Study (MiD) enrolled 66 patients on maintenance HD who were implanted with loop recorders and followed for 6 months. We analyzed associations of predialysis laboratory values with clinically significant bradyarrhythmia or asystole (CSBA) during the 12 hours before an HD session. Associations with CSBA were analyzed with mixed-effect models. Adjusted negative binomial mixed-effect regression was used to estimate incidence rate ratios (IRR) for CSBA. We additionally evaluated associations of CSBA at any time during follow-up with time-averaged dialytic and laboratory parameters and associations of peridialytic parameters with occurrence of CSBA from the start of one HD session to the beginning of the next. RESULTS: There were 551 CSBA that occurred in the last 12 hours of the interdialytic interval preceding 100 HD sessions in 12% of patients and 1475 CSBA events in 23% of patients overall. We did not identify significant associations between dialytic parameters or serum electrolytes and CSBA in the last 12 hours of the interdialytic interval in adjusted analyses. Median time-averaged ultrafiltration rate was significantly higher in individuals without CSBA (9.8 versus 8, CONCLUSIONS: Although a few factors had modest associations with CSBA in some analyses, we did not identify any robust associations of modifiable parameters with CSBA in the MiD Study. Further investigation is needed to understand the high rates of arrhythmia in the hemodialysis population

    Temporal evolution of hemodynamics in murine arteriovenous fistula: A micro-CT based CFD study.

    Get PDF
    In this study, we investigated the hemodynamic characteristics of arteriovenous fistulas (AVFs) in murine models using micro-CT based computational fluid dynamics (CFD). By combining high-resolution micro-CT imaging with ultrasound flow measurements, our methodology offers a cost-effective and efficient alternative to traditional MRI-based approaches. CFD simulations performed at 7 and 21 days post-surgery revealed significant temporal changes in both geometry and hemodynamics. Geometric analysis showed that the proximal artery diameter increased from 0.29 mm to 0.38 mm, whereas the initial 2 mm fistula segment showed a 21.6% decrease (0.74 mm to 0.58 mm). Blood flow through the AVF nearly doubled from 1.33 mL/min to 2.57 mL/min. Time-averaged wall shear stress (TAWSS) peak values and locations changed from 142 Pa (day 7) within the proximal artery to 200 Pa (day 21) in the stenotic region. The oscillatory shear index (OSI) showed marked elevation at the anastomosis (increasing from 0.22 to 0.48), indicating disturbed flow development. An inverse relationship between TAWSS and OSI was identified, consistent with previous studies. Our methodology demonstrates the capability to analyze relationships between early hemodynamics and subsequent geometric changes. This approach could enable identification of regions susceptible to stenosis development and monitoring of AVF maturation, which could ultimately lead to quantitative metrics to evaluate surgical outcomes and early therapeutic interventions

    Subnormothermic Oxygenated Machine Perfusion (24 h) in DCD Kidney Transplantation

    Get PDF
    Background: Ex vivo kidney perfusion is an evolving platform that demonstrates promise in preserving and rehabilitating the kidney grafts. Despite this, there is little consensus on the optimal perfusion conditions. Hypothermic perfusion offers limited functional assessment, whereas normothermic perfusion requires a more complex mechanical system and perfusate. Subnormothermic machine perfusion (SNMP) has the potential to combine the advantages of both approaches but has undergone limited investigation. Therefore, the present study sought to determine the suitability of SNMP for extended kidney preservation. Methods: SNMP at 22-25 °C was performed on a portable device for 24 h with porcine kidneys. Graft assessment included measurement of mechanical parameters and biochemical analysis of the perfusate using point-of-care tests. To investigate the viability of kidneys preserved by SNMP, porcine kidney autotransplants were performed in a donation after circulatory death (DCD) model. SNMP was also compared with static cold storage (SCS). Finally, follow-up experiments were conducted in a subset of human kidneys to test the translational significance of findings in porcine kidneys. Results: In the perfusion-only cohort, porcine kidneys all displayed successful perfusion for 24 h by SNMP, evidenced by stable mechanical parameters and biological markers of graft function. Furthermore, in the transplant cohort, DCD grafts with 30 min of warm ischemic injury demonstrated superior posttransplant graft function when preserved by SNMP in comparison with SCS. Finally, human kidneys that underwent 24-h perfusion exhibited stable functional and biological parameters consistent with observations in porcine organs. Conclusions: These observations demonstrate the suitability and cross-species generalizability of subnormothermic machine perfusion to maintain stable kidney perfusion and provide foundational evidence for improved posttransplant graft function of DCD kidneys after SNMP compared with SCS

    Design and baseline characteristics of the finerenone in reducing cardiovascular mortality and morbidity in diabetic kidney disease trial

    Get PDF
    Background: Among people with diabetes, those with kidney disease have exceptionally high rates of cardiovascular (CV) morbidity and mortality and progression of their underlying kidney disease. Finerenone is a novel, nonsteroidal, selective mineralocorticoid receptor antagonist that has shown to reduce albuminuria in type 2 diabetes (T2D) patients with chronic kidney disease (CKD) while revealing only a low risk of hyperkalemia. However, the effect of finerenone on CV and renal outcomes has not yet been investigated in long-term trials. Patients and Methods: The Finerenone in Reducing CV Mortality and Morbidity in Diabetic Kidney Disease (FIGARO-DKD) trial aims to assess the efficacy and safety of finerenone compared to placebo at reducing clinically important CV and renal outcomes in T2D patients with CKD. FIGARO-DKD is a randomized, double-blind, placebo-controlled, parallel-group, event-driven trial running in 47 countries with an expected duration of approximately 6 years. FIGARO-DKD randomized 7,437 patients with an estimated glomerular filtration rate >= 25 mL/min/1.73 m(2) and albuminuria (urinary albumin-to-creatinine ratio >= 30 to <= 5,000 mg/g). The study has at least 90% power to detect a 20% reduction in the risk of the primary outcome (overall two-sided significance level alpha = 0.05), the composite of time to first occurrence of CV death, nonfatal myocardial infarction, nonfatal stroke, or hospitalization for heart failure. Conclusions: FIGARO-DKD will determine whether an optimally treated cohort of T2D patients with CKD at high risk of CV and renal events will experience cardiorenal benefits with the addition of finerenone to their treatment regimen. Trial Registration: EudraCT number: 2015-000950-39; ClinicalTrials.gov identifier: NCT02545049
    corecore