2,251 research outputs found

    Exploring Team Growth and Fixed Mindsets in Work Teams at a Large Korean Corporation

    Get PDF
    We conducted a qualitative study to understand how team mindsets can be manifested in work teams. We interviewed 21 participants from seven departments in one of the big corporations in Korea

    Closed P2P system for PVR-based file sharing

    Full text link

    Digital Workflow for Retrofitting a Surveyed Crown Using a Removable Partial Denture as an Antagonist

    Full text link
    Digital workflow expedites the procedure of retrofitting a surveyed crown against an existing removable partial denture (RPD). This article describes a simple and straightforward technique of digital workflow where an existing RPD is scanned as an antagonist to design the rest seat, guide plane, and height of contour of a surveyed crown.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/156192/2/jopr13187_am.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/156192/1/jopr13187.pd

    Temperature dependence of Mott transition in VO_2 and programmable critical temperature sensor

    Full text link
    The temperature dependence of the Mott metal-insulator transition (MIT) is studied with a VO_2-based two-terminal device. When a constant voltage is applied to the device, an abrupt current jump is observed with temperature. With increasing applied voltages, the transition temperature of the MIT current jump decreases. We find a monoclinic and electronically correlated metal (MCM) phase between the abrupt current jump and the structural phase transition (SPT). After the transition from insulator to metal, a linear increase in current (or conductivity) is shown with temperature until the current becomes a constant maximum value above T_{SPT}=68^oC. The SPT is confirmed by micro-Raman spectroscopy measurements. Optical microscopy analysis reveals the absence of the local current path in micro scale in the VO_2 device. The current uniformly flows throughout the surface of the VO_2 film when the MIT occurs. This device can be used as a programmable critical temperature sensor.Comment: 4 pages, 3 figure

    Simple Use of the Suppository Type Povidone-Iodine Can Prevent Infectious Complications in Transrectal Ultrasound-Guided Prostate Biopsy

    Get PDF
    Purpose. To determine the effect of simple use of suppository povidone-iodine on infectious complications after transrectal ultrasonography-guided biopsy of the prostate. Methods. All 481 patients are included and received antibiotic prophylaxis. Among them, 360 patients received povidone-iodine suppository (Gynobetadine; 200 mg) immediately prior to biopsy and 121 patients did not. Infectious complications were classified. To evaluate bactericidal effects, we counted bacterial colonies in the rectum, harvested from a rectal swab before insertion of the suppository and after biopsy. Aliquots of the suspended bacterial strains were added to Mueller-Hinton agar medium for incubation. Colony counts were determined. Results. Infectious complications developed in 1 case (0.3%) in the rectal preparation group (Group 1) and in 8 cases (6.6%) in the nonrectal preparation group (Group 2). One in Group 1 had a fever without sepsis. Two patients had sepsis and six had fever without sepsis in Group 2. Rectal preparation was a statistically significant risk factor influencing the development of infectious complications. In vitro experiments, the mean number of colony-forming units decreased 99.9% after the rectal povidone-iodine preparation. Conclusions. All through the biopsy, povidone-iodine melted into the rectum and decreased the bacterial colony count. Simple use of povidone-iodine suppository before prostate biopsy minimizes the risk of infectious complications

    Inaccuracy of intraocular pressure measurement in congenital corneal opacity: three case reports

    Get PDF
    Background To report three cases of congenital corneal opacity where intraocular pressure (IOP) readings were high despite the use of multiple anti-glaucoma eye drops and normalized after corneal transplantation. Case presentation Three Korean infants presented with bilateral dense stromal opacification which had been present since birth. IOPs measured by rebound tonometer were high despite administration of multiple anti-glaucoma medications. One eye of each patient underwent penetrating keratoplasty (PK) because corneal opacity impaired visual development. Immediately after PK, IOPs were normalized and maintained normal without medication, whereas they remained high in the contralateral unoperated eye. On histology, stromal fibrosis was observed in the removed corneal button, and molecular assays revealed increased levels of type 1 and 5 collagens. Conclusion The IOP measurement using the conventional applanation-based tonometry can be inaccurate in congenital corneal opacity which is marked by corneal fibrosis. Therefore, IOP values should be interpreted with caution in these patients, and the possibility of false-positive diagnosis of glaucoma considered.This study was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and future Planning (NRF-2018R1A2B2004108). The funder supported funding for molecular assay for corneal collagens in this study
    corecore