2 research outputs found
Doppler assessment of aortic stenosis: reading the peak velocity is superior to velocity time integral
Introduction Previous studies of the reproducibility of echocardiographic assessment of aortic stenosis have compared only a pair of observers. The aim of this study was to assess reproducibility across a large group of observers and compare the reproducibility of reading the peak versus the velocity time integral.Methods 25 observers reviewed continuous wave (CW) aortic valve and pulsed wave (PW) LVOT Doppler traces from 20 sequential cases of aortic stenosis in random order. Each operator unknowingly measured the peak velocity and velocity time integral (VTI) twice for each case, with the traces stored for analysis. We undertook a mixed-model analysis of the sources of variance for peak and VTI measurements.Results Measuring the peak is more reproducible than VTI for both PW (coefficient of variation 9.6% versus 15.9%, p<0.001) and CW traces (coefficient of variation 4.0% versus 9.6%, p<0.001), as shown in Figure 1. VTI is inferior because, compared to the middle, it is difficult to reproducibly trace the steep beginning (standard deviation 3.7x and 1.8x larger for CW and PW respectively) and end (standard deviation 2.4x and 1.5x larger for CW and PW respectively). Dimensionless index reduces the coefficient of variation (19% reduction for VTI, 11% reduction for peak) partly because it cancels correlated errors: an operator who over-measures a CW trace is likely to over-measure the matching PW trace (r=0.39, p<0.001?for VTI, r=0.41, p<0.001?for peak), as shown in Figure 2.Conclusions It is more reproducible to measure the peak of a Doppler trace than the VTI, because it is difficult to trace the steep slopes at the beginning and end reproducibly. The difference is non-trivial: an average operator would be 95% confident detecting a 11.1% change in peak velocity but a much larger 27.4% change in VTI. A clinical trial of an intervention for aortic stenosis with a VTI endpoint would need to be 2.4 times larger than one with a peak velocity endpoint. Part of the benefit of dimensionless index in improving reproducibility arises because it cancels individual operators tendency to consistently over- or under-read traces.</p
Open-source, vendor-independent, automated multi-beat tissue Doppler echocardiography analysis
Current guidelines for measuring cardiac function by tissue Doppler recommend using multiple beats, but this has a time cost for human operators. We present an open-source, vendor-independent, drag-and-drop software capable of automating the measurement process. A database of ~8000 tissue Doppler beats (48 patients) from the septal and lateral annuli were analyzed by three expert echocardiographers. We developed an intensity- and gradient-based automated algorithm to measure tissue Doppler velocities. We tested its performance against manual measurements from the expert human operators. Our algorithm showed strong agreement with expert human operators. Performance was indistinguishable from a human operator: for algorithm, mean difference and SDD from the mean of human operators’ estimates 0.48?±?1.12 cm/s (R2?=?0.82); for the humans individually this was 0.43?±?1.11 cm/s (R2?=?0.84), ?0.88?±?1.12 cm/s (R2?=?0.84) and 0.41?±?1.30 cm/s (R2?=?0.78). Agreement between operators and the automated algorithm was preserved when measuring at either the edge or middle of the trace. The algorithm was 10-fold quicker than manual measurements (p?</p