17 research outputs found

    Live Demonstration: Upper Limb Prosthetic Control Using Toe Gesture Sensors and Various Touch Interfaces

    Get PDF
    Orienting technology, through new techniques, to rehabilitate the disabled and physically challenged and to help elderly is a noble cause, which will improve the quality of life of millions. Prosthetics is one of the important research area where robotic technology serves its best for medical sciences. Conventionally various prosthetic control techniques exists and each has their own advantages and disadvantages. These control techniques ranges from simply implementable, cable-controlled, body-powered prosthetics to technologically challenging Targeted Muscle Reinnervation (TMR) based prosthetics control system. The effectiveness of a upper-limb prosthetic control method for wide-spread application depends on various factors such as cost-effectiveness, ability for easy fabrication, ruggedness, repeatability on daily use, easily installable, usability, ability to bring dexterity and accuracy to perform various gestures/associated activities etc. The current techniques have major drawbacks, namely: with EMG there is a need of relatively complex electronics/sensor electrodes and classification algorithms for implementing large gesture range; EEG suffers from reliability issue and cost; sweating and placement positions of electrodes may interfere with reliable working in case of both EEG and EMG techniques; need of invasive surgery and associated high cost in case of TMR or implanted myo/neural interface etc. We will present demo of a robust, non-invasive, simple, touch-based toe gesture sensor system for upper limb prosthetic control

    Inorganic micro/nanostructures-based high-performance flexible electronics for electronic skin application

    Get PDF
    Electronics in the future will be printed on diverse substrates, benefiting several emerging applications such as electronic skin (e-skin) for robotics/prosthetics, flexible displays, flexible/conformable biosensors, large area electronics, and implantable devices. For such applications, electronics based on inorganic micro/nanostructures (IMNSs) from high mobility materials such as single crystal silicon and compound semiconductors in the form of ultrathin chips, membranes, nanoribbons (NRs), nanowires (NWs) etc., offer promising high-performance solutions compared to conventional organic materials. This thesis presents an investigation of the various forms of IMNSs for high-performance electronics. Active components (from Silicon) and sensor components (from indium tin oxide (ITO), vanadium pentaoxide (V2O5), and zinc oxide (ZnO)) were realised based on the IMNS for application in artificial tactile skin for prosthetics/robotics. Inspired by human tactile sensing, a capacitive-piezoelectric tandem architecture was realised with indium tin oxide (ITO) on a flexible polymer sheet for achieving static (upto 0.25 kPa-1 sensitivity) and dynamic (2.28 kPa-1 sensitivity) tactile sensing. These passive tactile sensors were interfaced in extended gate mode with flexible high-performance metal oxide semiconductor field effect transistors (MOSFETs) fabricated through a scalable process. The developed process enabled wafer scale transfer of ultrathin chips (UTCs) of silicon with various devices (ultrathin chip resistive samples, metal oxide semiconductor (MOS) capacitors and n‐channel MOSFETs) on flexible substrates up to 4″ diameter. The devices were capable of bending upto 1.437 mm radius of curvature and exhibited surface mobility above 330 cm2/V-s, on-to-off current ratios above 4.32 decades, and a subthreshold slope above 0.98 V/decade, under various bending conditions. While UTCs are useful for realizing high-density high-performance micro-electronics on small areas, high-performance electronics on large area flexible substrates along with low-cost fabrication techniques are also important for realizing e-skin. In this regard, two other IMNS forms are investigated in this thesis, namely, NWs and NRs. The controlled selective source/drain doping needed to obtain transistors from such structure remains a bottleneck during post transfer printing. An attractive solution to address this challenge based on junctionless FETs (JLFETs), is investigated in this thesis via technology computer-aided design (TCAD) simulation and practical fabrication. The TCAD optimization implies a current of 3.36 mA for a 15 μm channel length, 40 μm channel width with an on-to-off ratio of 4.02x 107. Similar to the NRs, NWs are also suitable for realizing high performance e-skin. NWs of various sizes, distribution and length have been fabricated using various nano-patterning methods followed by metal assisted chemical etching (MACE). Synthesis of Si NWs of diameter as low as 10 nm and of aspect ratio more than 200:1 was achieved. Apart from Si NWs, V2O5 and ZnO NWs were also explored for sensor applications. Two approaches were investigated for printing NWs on flexible substrates namely (i) contact printing and (ii) large-area dielectrophoresis (DEP) assisted transfer printing. Both approaches were used to realize electronic layers with high NW density. The former approach resulted in 7 NWs/μm for bottom-up ZnO and 3 NWs/μm for top-down Si NWs while the latter approach resulted in 7 NWs/μm with simultaneous assembly on 30x30 electrode patterns in a 3 cm x 3 cm area. The contact-printing system was used to fabricate ZnO and Si NW-based ultraviolet (UV) photodetectors (PDs) with a Wheatstone bridge (WB) configuration. The assembled V2O5 NWs were used to realize temperature sensors with sensitivity of 0.03% /K. The sensor arrays are suitable for tactile e-skin application. While the above focuses on realizing conventional sensing and addressing elements for e-skin, processing of a large amount of data from e-skin has remained a challenge, especially in the case of large area skin. A Neural NW Field Effect Transistors (υ-NWFETs) based hardware-implementable neural network (HNN) approach for tactile data processing in e-skin is presented in the final part of this thesis. The concept is evaluated by interfacing with a fabricated kirigami-inspired e-skin. Apart from e-skin for prosthetics and robotics, the presented research will also be useful for obtaining high performance flexible circuits needed in many futuristic flexible electronics applications such as smart surgical tools, biosensors, implantable electronics/electroceuticals and flexible mobile phones

    van der Waals contact engineering of graphene field-effect transistors for large-area flexible electronics

    Get PDF
    Graphene has great potential for high-performance flexible electronics. Although studied for more than a decade, contacting graphene efficiently, especially for large-area, flexible electronics, is still a challenge. Here, by engineering the graphene-metal van der Waals (vdW) contact, we demonstrate that ultra-low contact resistance is achievable via a bottom-contact strategy incorporating a simple transfer process without any harsh thermal treatment (>150°C). The majority of the fabricated devices show contact resistances below 200 Ω·µm with values as low as 65 Ω·µm achievable. This is on a par with the state-of-the-art top- and edge-contacted graphene field-effect transistors (GFETs). Further, our study reveals that these contacts, despite the presumed weak nature of the vdW interaction, are stable under various bending conditions, thus guaranteeing compatibility with flexible electronics with improved performance. This work illustrates the potential of the previously underestimated vdW contact approach for large-area flexible electronics

    Graphene–Graphite Polyurethane Composite Based High‐Energy Density Flexible Supercapacitors

    Get PDF
    Energy autonomy is critical for wearable and portable systems and to this end storage devices with high-energy density are needed. This work presents high-energy density flexible supercapacitors (SCs), showing three times the energy density than similar type of SCs reported in the literature. The graphene–graphite polyurethane (GPU) composite based SCs have maximum energy and power densities of 10.22 µWh cm−2 and 11.15 mW cm−2, respectively, at a current density of 10 mA cm−2 and operating voltage of 2.25 V (considering the IR drop). The significant gain in the performance of SCs is due to excellent electroactive surface per unit area (surface roughness 97.6 nm) of GPU composite and high electrical conductivity (0.318 S cm−1). The fabricated SCs show stable response for more than 15 000 charging/discharging cycles at current densities of 10 mA cm−2 and operating voltage of 2.5 V (without considering the IR drop). The developed SCs are tested as energy storage devices for wide applications, namely: a) solar-powered energy-packs to operate 84 light-emitting diodes (LEDs) for more than a minute and to drive the actuators of a prosthetic limb; b) powering high-torque motors; and c) wristband for wearable sensors

    Tacsac: a wearable haptic device with capacitive touch-sensing capability for tactile display

    Get PDF
    This paper presents a dual-function wearable device (Tacsac) with capacitive tactile sensing and integrated tactile feedback capability to enable communication among deafblind people. Tacsac has a skin contactor which enhances localized vibrotactile stimulation of the skin as a means of feedback to the user. It comprises two main modules—the touch-sensing module and the vibrotactile module; both stacked and integrated as a single device. The vibrotactile module is an electromagnetic actuator that employs a flexible coil and a permanent magnet assembled in soft poly (dimethylsiloxane) (PDMS), while the touch-sensing module is a planar capacitive metal-insulator-metal (MIM) structure. The flexible coil was fabricated on a 50 µm polyimide (PI) sheet using Lithographie Galvanoformung Abformung (LIGA) micromoulding technique. The Tacsac device has been tested for independent sensing and actuation as well as dual sensing-actuation mode. The measured vibration profiles of the actuator showed a synchronous response to external stimulus for a wide range of frequencies (10 Hz to 200 Hz) within the perceivable tactile frequency thresholds of the human hand. The resonance vibration frequency of the actuator is in the range of 60–70 Hz with an observed maximum off-plane displacement of 0.377 mm at coil current of 180 mA. The capacitive touch-sensitive layer was able to respond to touch with minimal noise both when actuator vibration is ON and OFF. A mobile application was also developed to demonstrate the application of Tacsac for communication between deafblind person wearing the device and a mobile phone user who is not deafblind. This advances existing tactile displays by providing efficient two-way communication through the use of a single device for both localized haptic feedback and touch-sensing

    Global, regional, and national burden of colorectal cancer and its risk factors, 1990–2019: a systematic analysis for the Global Burden of Disease Study 2019

    Get PDF
    Funding: F Carvalho and E Fernandes acknowledge support from Fundação para a Ciência e a Tecnologia, I.P. (FCT), in the scope of the project UIDP/04378/2020 and UIDB/04378/2020 of the Research Unit on Applied Molecular Biosciences UCIBIO and the project LA/P/0140/2020 of the Associate Laboratory Institute for Health and Bioeconomy i4HB; FCT/MCTES through the project UIDB/50006/2020. J Conde acknowledges the European Research Council Starting Grant (ERC-StG-2019-848325). V M Costa acknowledges the grant SFRH/BHD/110001/2015, received by Portuguese national funds through Fundação para a Ciência e Tecnologia (FCT), IP, under the Norma Transitória DL57/2016/CP1334/CT0006.proofepub_ahead_of_prin

    The global burden of cancer attributable to risk factors, 2010-19 : a systematic analysis for the Global Burden of Disease Study 2019

    Get PDF
    Background Understanding the magnitude of cancer burden attributable to potentially modifiable risk factors is crucial for development of effective prevention and mitigation strategies. We analysed results from the Global Burden of Diseases, Injuries, and Risk Factors Study (GBD) 2019 to inform cancer control planning efforts globally. Methods The GBD 2019 comparative risk assessment framework was used to estimate cancer burden attributable to behavioural, environmental and occupational, and metabolic risk factors. A total of 82 risk-outcome pairs were included on the basis of the World Cancer Research Fund criteria. Estimated cancer deaths and disability-adjusted life-years (DALYs) in 2019 and change in these measures between 2010 and 2019 are presented. Findings Globally, in 2019, the risk factors included in this analysis accounted for 4.45 million (95% uncertainty interval 4.01-4.94) deaths and 105 million (95.0-116) DALYs for both sexes combined, representing 44.4% (41.3-48.4) of all cancer deaths and 42.0% (39.1-45.6) of all DALYs. There were 2.88 million (2.60-3.18) risk-attributable cancer deaths in males (50.6% [47.8-54.1] of all male cancer deaths) and 1.58 million (1.36-1.84) risk-attributable cancer deaths in females (36.3% [32.5-41.3] of all female cancer deaths). The leading risk factors at the most detailed level globally for risk-attributable cancer deaths and DALYs in 2019 for both sexes combined were smoking, followed by alcohol use and high BMI. Risk-attributable cancer burden varied by world region and Socio-demographic Index (SDI), with smoking, unsafe sex, and alcohol use being the three leading risk factors for risk-attributable cancer DALYs in low SDI locations in 2019, whereas DALYs in high SDI locations mirrored the top three global risk factor rankings. From 2010 to 2019, global risk-attributable cancer deaths increased by 20.4% (12.6-28.4) and DALYs by 16.8% (8.8-25.0), with the greatest percentage increase in metabolic risks (34.7% [27.9-42.8] and 33.3% [25.8-42.0]). Interpretation The leading risk factors contributing to global cancer burden in 2019 were behavioural, whereas metabolic risk factors saw the largest increases between 2010 and 2019. Reducing exposure to these modifiable risk factors would decrease cancer mortality and DALY rates worldwide, and policies should be tailored appropriately to local cancer risk factor burden. Copyright (C) 2022 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license.Peer reviewe

    Capacitive-Piezoelectric Tandem Architecture for Biomimetic Tactile Sensing in Prosthetic Hand

    No full text
    This paper presents our work on the development of a biomimetic tactile sensor and its integration with a 3D-printed prosthetic limb. Human tactile sensing involves sensing and processing of both static and dynamic stimuli. Here, a novel capacitive architecture in tandem with a piezoelectric structure has been used for achieving static and dynamic tactile sensing. Result of the capacitive sensing structure's characteristics was found to be non-linear varying from high sensitivity of 0.25 kPa -1 in low pressure range(<;100 Pa) to 0.002 kPa -1 in high pressure. The piezoelectric sensing structure exhibited a sensitivity of 2.28 kPa -1 . Readout and wireless communication of the tactile data was carried out to display in a mobile app which also performs processing of myoelectric signal to control the prosthesis

    Wafer Scale Transfer of Ultrathin Silicon Chips on Flexible Substrates for High Performance Bendable Systems

    No full text
    This paper presents an innovative approach for wafer scale transfer of ultrathin silicon chips on flexible substrates. The methodology is demonstrated with various devices (ultrathin chip resistive samples, metal oxide semiconductor (MOS) capacitors and n‐channel metal oxide semiconductor field effect transistors (MOSFETs)) on wafers up to 4″ diameter. This is supported by extensive electromechanical characterization and theoretical analysis, including finite element simulation, to evaluate the effect of bending and the critical breaking radius of curvature. The ultrathin chips on polyimide did not break until the radius of curvature of 1.437 mm. In the case of MOS capacitors the measured capacitance increases with increase in bending load. The changes in the transfer and output characteristics of ultrathin MOSFETs closely match with the theoretical model utilizing empirically determined parameters. Overall, the work demonstrates the efficacy of the new methodology presented here for wafer scale transfer of ultrathin chips on flexible substrates. The presented research will be useful for obtaining high performance and compact circuits needed in many futuristic flexible electronics applications such as implantable electronics and flexible displays. Further, it will open new avenues for realizing multilayered multimaterial (foil‐to‐foil) integrated bendable electronics
    corecore