3 research outputs found

    Enhancing the Reliability of Photovoltaic Systems in Microgrid at Campus Area

    Get PDF
    This paper assesses the reliability of photovoltaic systems within a microgrid, considering the system's operational mode and monthly data on solar radiation and load demand. The evaluation encompasses various reliability metrics, including microgrid failure rate, interruption duration, system unavailability, EENS, EIR, LOLE, and LOLP, with the objective of minimizing these parameters. The methodologies applied involve the Markov model and artificial intelligence algorithms such as Naive Bayes and Support Vector Machine (SVM). Results indicate that the microgrid exhibits enhanced reliability in an on-grid mode configuration, with a LOLP value of 0.0008. Furthermore, employing machine learning, specifically SVM, for LOLP calculation based on solar radiation yields a more precise value of 0.7245. This study offers valuable insights for policymakers and system designers in determining the optimal configuration for microgrids.This paper assesses the reliability of photovoltaic systems within a microgrid, considering the system's operational mode and monthly data on solar radiation and load demand. The evaluation encompasses various reliability metrics, including microgrid failure rate, interruption duration, system unavailability, EENS, EIR, LOLE, and LOLP, with the objective of minimizing these parameters. The methodologies applied involve the Markov model and artificial intelligence algorithms such as Naive Bayes and Support Vector Machine (SVM). Results indicate that the microgrid exhibits enhanced reliability in an on-grid mode configuration, with a LOLP value of 0.0008. Furthermore, employing machine learning, specifically SVM, for LOLP calculation based on solar radiation yields a more precise value of 0.7245. This study offers valuable insights for policymakers and system designers in determining the optimal configuration for microgrids

    Simulasi Energi dan Keekonomian Sistem Pembangkit Listrik Tenaga Surya (PLTS) untuk Fungsi Peak Load Shaving pada Bangunan di Lingkungan Kampus ITB

    Full text link
    Pada paper ini, dilakukan simulasi produksi energi dan keekonomian dari sistem PLTS terintegrasi dengan jaringan listrik yang merupakan bagian dari proyek instalasi sistem smart microgrid di bangunan Center for Advanced Sciences (CAS) ITB. Terdapat dua sistem PLTS yang dianalisis yaitu sistem PLTS 40 kWp tanpa baterai, dan sistem PLTS 10 kWp dengan baterai yang terhubung ke beban kritis. Kedua sistem PLTS tersebut dirancang dengan tujuan peak load shaving yang dapat meminimalisir adanya ketidakseimbangan antara produksi energi surya dan permintaan listrik. Kedua sistem dianalisis dengan metoda simulasi berdasarkan aspek energi dan ekonomi menggunakan perangkat lunak PVsyst dan Homer. Dari hasil simulasi sistem PLTS 40 kWp didapatkan nilai performance ratio (PR) sebesar 0,833, renewable fraction (RF) sebesar 18,73%, dan cost of energy (COE) sebesar Rp 1.251,85/kWh yang mana nilai PR dan COE telah memenuhi target bisnis: PR > 0.8 dan COE < Rp 1.467,28/kWh tetapi tidak memenuhi target RF > 35%. Sementara dari hasil simulasi sistem PLTS 10 kWp didapatkan nilai PR sebesar 0,77, RF sebesar 44,38% hingga 52,19% pada rentang depth of discharge 20% - 80%, dan COE sebesar Rp 2.103/kWh hingga Rp 6.315/kWh pada rentang DoD 20% - 80% yang mana hanya nilai RF telah memenuhi target bisnis

    Sistem Arsitektur Manajemen Bangunan untuk Memaksimalkan Swakonsumsi pada Bangunan Universitas: Studi Kasus

    No full text
    Due to its intermittent nature, significant adoption of solar PV into the grid can decrease grid reliability. One solution to increase it is to increase PV self-consumption with two methods: adding Energy Storage System (ESS) and conducting Demand Side Management (DSM). University building has a distinct characteristic in its complex dynamics. Therefore, there is a lack of research to control both methods of increasing self-consumption. This paper aimed to do an integrated literature review on increasing self-consumption and then propose a system architecture recommendation for university building management based on the review. The Smart Grid Architectural Model (SGAM) evaluated the case study object. The result showed that a data-driven controller has been chosen as the most suitable controller for the university building management system. The data needed to build a data-driven controller could be obtained through readily available sensors in the case study object, making it feasible for implementation.Dikarenakan sifatnya yang intermitten, adopsi energi dari PV surya ke dalam jaringan dapat mengurangi keandalan jaringan. Salah satu solusi untuk meningkatkannya adalah dengan meningkatkan swakonsumsi PV dengan dua metode: menambahkan Sistem Penyimpanan Energi (SPBE) dan melakukan manajemen sisi permintaan. Gedung universitas memiliki karakteristik yang berbeda dalam dinamika kompleksnya. Kurangnya penelitian untuk mengendalikan kedua metode ini di gedung-gedung universitas disebabkan oleh karakteristik ini. Makalah ini bertujuan untuk melakukan tinjauan literatur terintegrasi tentang upaya meningkatkan konsumsi sendiri kemudian mengusulkan rekomendasi arsitektur sistem untuk manajemen gedung universitas berdasarkan tinjauan tersebut. Kami kemudian mengevaluasi objek studi kasus menggunakan Smart Grid Architecture Model (SGAM). Hasilnya menunjukkan bahwa pengendali berbasis data telah dipilih sebagai pengendali yang paling cocok untuk sistem manajemen gedung universitas
    corecore