772 research outputs found
The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was
operated with 150 GeV/c muon and pion beams in Ne/(5%CH), Ar/(5%CH) and
Ar/(7%CO); signals were recorded with 1 cm square pads and SRS/APV25
electronics. Detection efficiency values greater than 98% were reached in all
the gas mixtures, at average pad multiplicity of 1.2. The use of the
10{\Omega}cm resistive plate resulted in a completely discharge-free
operation also in intense pion beams. The efficiency remained essentially
constant at 98-99% up to fluxes of 10Hz/cm, dropping by a few %
when approaching 10 Hz/cm. These results pave the way towards
cost-effective, robust, efficient, large-scale detectors for a variety of
applications in future particle, astro-particle and applied fields. A potential
target application is digital hadron calorimetry.Comment: presented at the 2016 VIenna Conf. On instrumentation. Submitted to
the Conference proceeding
Optical readout: a tool for studying gas-avalanche processes
Optical recording of avalanche-induced photons is an interesting tool for
studying basic physics processes in gaseous detectors. In this work we
demonstrate the potential of optical readout in avalanche-propagation
investigations in Thick Gas Electron Multipliers (THGEMs) operated with Ne/CF4
(95/5). We present the results of direct measurements, with single- and
cascaded-THGEM detectors irradiated with soft x-rays, of the hole-multiplicity
and avalanche asymmetry within holes, as a function of detector parameters.
Further study directions are discussed
Towards a large-area RPWELL detector: design optimization and performance
We present a new design and assembly procedure of a large-area gas-avalanche
Resistive-Plate WELL (RPWELL) detector. A prototype
was tested in muon beam at CERN-SPS, presenting improved
performances compared to previous ones: MIP detection efficiency over 96\% with
3\% uniformity across the entire detector area, a charge gain of
with a uniformity of 22\%, and discharge
probability below with a few single hotspots attributed to
production imperfections. These results pave the way towards further up-scaling
detectors of this kind
The cryogenic RWELL: a stable charge multiplier for dual-phase liquid-argon detectors
The operation of a cryogenic Resistive WELL (RWELL) in liquid argon vapor is
reported for the first time. It comprises a Thick Gas Electron Multiplier
(THGEM) structure coupled to a resistive Diamond-Like Carbon (DLC) anode
deposited on an insulating substrate. The multiplier was operated at cryogenic
temperature (90~K, 1.2~bar) in saturated argon vapor and characterized in terms
of charge gain and electrical stability. A comparative study with standard,
non-resistive THGEM (a.k.a LEM) and WELL multipliers, confirmed the RWELL
advantages in terms of discharge quenching - thus superior gain and stability
Novel resistive charge-multipliers for dual-phase LAr-TPCs: towards stable operation at higher gains
Cryogenic versions of Resistive WELL (RWELL) and Resistive Plate WELL
(RPWELL) detectors have been developed, aimed at stable avalanche
multiplication of ionization electrons in dual-phase TPCs. In the RWELL, a thin
resistive layer deposited on top of an insulator is inserted in between the
electron multiplier (THGEM) and the readout anode; in the RPWELL, a resistive
plate is directly coupled to the THGEM. Radiation-induced ionization electrons
in the liquid are extracted into the gaseous phase. They drift into the THGEM's
holes where they undergo charge multiplication. Embedding resistive materials
into the multiplier proved to enhance operation stability due to the mitigation
of electrical discharges - thus allowing operation at higher charge gain
compared to standard THGEM (a.k.a. LEM) multipliers. We present the detector
concepts and report on the main preliminary results
Targeted Next-Generation Sequencing Indicates a Frequent Oligogenic Involvement in Primary Ovarian Insufficiency Onset
Primary ovarian insufficiency (POI) is one of the major causes of female infertility associated with the premature loss of ovarian function in about 3.7% of women before the age of 40. This disorder is highly heterogeneous and can manifest with a wide range of clinical phenotypes, ranging from ovarian dysgenesis and primary amenorrhea to post-pubertal secondary amenorrhea, with elevated serum gonadotropins and hypoestrogenism. The ovarian defect still remains idiopathic in some cases; however, a strong genetic component has been demonstrated by the next-generation sequencing (NGS) approach of familiar and sporadic POI cases. As recent evidence suggested an oligogenic architecture for POI, we developed a target NGS panel with 295 genes including known candidates and novel genetic determinants potentially involved in POI pathogenesis. Sixty-four patients with early onset POI (range: 10–25 years) of our cohort have been screened with 90% of target coverage at 50×. Here, we report 48 analyzed patients with at least one genetic variant (75%) in the selected candidate genes. In particular, we found the following: 11/64 patients (17%) with two variants, 9/64 (14%) with three variants, 9/64 (14%) with four variants, 3/64 (5%) with five variants, and 2/64 (3%) with six variants. The most severe phenotypes were associated with either the major number of variations or a worse prediction in pathogenicity of variants. Bioinformatic gene ontology analysis identified the following major pathways likely affected by gene variants: 1) cell cycle, meiosis, and DNA repair; 2) extracellular matrix remodeling; 3) reproduction; 4) cell metabolism; 5) cell proliferation; 6) calcium homeostasis; 7) NOTCH signaling; 8) signal transduction; 9) WNT signaling; 10) cell death; and 11) ubiquitin modifications. Consistently, the identified pathways have been described in other studies dissecting the mechanisms of folliculogenesis in animal models of altered fertility. In conclusion, our results contribute to define POI as an oligogenic disease and suggest novel candidates to be investigated in patients with POI
Cryogenic RPWELL: a novel charge-readout element for dual-phase argon TPCs
The first operation of a cryogenic Resistive Plate WELL (RPWELL) detector in
the saturated vapor of liquid argon is reported. The RPWELL detector was
composed of a Thick Gas Electron Multiplier (THGEM) electrode coupled to a
metallic anode via FeO/YSZ ceramics (FeO in weight equal to
75), with tunable bulk resistivity in the range 10 - 10
cm. The detector was operated at liquid argon temperature in
saturated argon vapor (90~K, 1.2~bar) and characterized in terms of its
effective charge gain and stability against discharges. Maximum stable gain of
G17 was obtained, without discharges. In addition, preliminary results
from novel 3D-printed thermoplastic plates doped with carbon nanotubes are
presented
- …