40 research outputs found

    Geant4-based simulations of charge collection in CMOS Active Pixel Sensors

    No full text
    Geant4 is an object-oriented toolkit for the simulation of the interaction of particles and radiation with matter. It provides a snapshot of the state of a simulated particle in time, as it travels through a specified geometry. One important area of application is the modelling of radiation detector systems. Here, we extend the abilities of such modelling to include charge transport and sharing in pixelated CMOS Active Pixel Sensors (APSs); though similar effects occur in other pixel detectors. The CMOS APSs discussed were developed in the framework of the PRaVDA consortium to assist the design of custom sensors to be used in an energy-range detector for proton Computed Tomography (pCT). The development of ad-hoc classes, providing a charge transport model for a CMOS APS and its integration into the standard Geant4 toolkit, is described. The proposed charge transport model includes, charge generation, diffusion, collection, and sharing across adjacent pixels, as well as the full electronic chain for a CMOS APS. The proposed model is validated against experimental data acquired with protons in an energy range relevant for pCT.</p

    Using a large area CMOS APS for direct chemiluminescence detection in western blotting electrophoresis

    No full text
    Western blotting electrophoretic sequencing is an analytical technique widely used in Functional Proteomics to detect, recognize and quantify specific labelled proteins in biological samples. A commonly used label for western blotting is Enhanced ChemiLuminescence (ECL) reagents based on fluorescent light emission of Luminol at 425nm. Film emulsion is the conventional detection medium, but is characterized by non-linear response and limited dynamic range. Several western blotting digital imaging systems have being developed, mainly based on the use of cooled Charge Coupled Devices (CCDs) and single avalanche diodes that address these issues. Even so these systems present key drawbacks, such as a low frame rate and require operation at low temperature. Direct optical detection using Complementary Metal Oxide Semiconductor (CMOS) Active Pixel Sensors (APS) could represent a suitable digital alternative for this application. In this paper the authors demonstrate the viability of direct chemiluminescent light detection in western blotting electrophoresis using a CMOS APS at room temperature. Furthermore, in recent years, improvements in fabrication techniques have made available reliable processes for very large imagers, which can be now scaled up to wafer size, allowing direct contact imaging of full size western blotting samples. We propose using a novel wafer scale APS (12.8 cm�13.2 cm), with an array architecture using two different pixel geometries that can deliver an inherently low noise and high dynamic range image at the same time representing a dramatic improvement with respect to the current western blotting imaging systems. © 2012 SPIE.</p

    DynAMITe: a prototype large area CMOS APS for breast cancer diagnosis using x-ray diffraction measurements

    No full text
    X-ray diffraction studies are used to identify specific materials. Several laboratory-based x-ray diffraction studies were made for breast cancer diagnosis. Ideally a large area, low noise, linear and wide dynamic range digital x-ray detector is required to perform x-ray diffraction measurements. Recently, digital detectors based on Complementary Metal-Oxide- Semiconductor (CMOS) Active Pixel Sensor (APS) technology have been used in x-ray diffraction studies. Two APS detectors, namely Vanilla and Large Area Sensor (LAS), were developed by the Multidimensional Integrated Intelligent Imaging (MI-3) consortium to cover a range of scientific applications including x-ray diffraction. The MI-3 Plus consortium developed a novel large area APS, named as Dynamically Adjustable Medical Imaging Technology (DynAMITe), to combine the key characteristics of Vanilla and LAS with a number of extra features. The active area (12.8 × 13.1 cm 2) of DynaMITe offers the ability of angle dispersive x-ray diffraction (ADXRD). The current study demonstrates the feasibility of using DynaMITe for breast cancer diagnosis by identifying six breast-equivalent plastics. Further work will be done to optimize the system in order to perform ADXRD for identification of suspicious areas of breast tissue following a conventional mammogram taken with the same sensor. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).</p

    Radiation hardness of a large area CMOS active pixel sensor for bio-medical application

    No full text
    A wafer scale CMOS Active Pixel Sensor has been designed employing design techniques of transistor enclosed geometry and P+ doped guard rings to offer ionizing radiation tolerance. The detector was irradiated with 160 kVp X-rays up to a total dose of 94 kGy(Si) and remained functional. The radiation damage produced in the device has been studied, resulting in a dark current density increase per decade of 96±5 pA/cm2/decade and a damage threshold of 204 Gy(Si). The damage produced in the detector has been compared with a commercially available CMOS APS, showing a radiation tolerance about 100 times higher. Moreover Monte Carlo simulations have been performed to evaluate primary and secondary energy deposition in each of the detector stages. © 2012 IEEE.</p

    DynAMITe: a prototype large area CMOS APS for breast cancer diagnosis using x-ray diffraction measurements

    No full text
    X-ray diffraction studies are used to identify specific materials. Several laboratory-based x-ray diffraction studies were made for breast cancer diagnosis. Ideally a large area, low noise, linear and wide dynamic range digital x-ray detector is required to perform x-ray diffraction measurements. Recently, digital detectors based on Complementary Metal-Oxide- Semiconductor (CMOS) Active Pixel Sensor (APS) technology have been used in x-ray diffraction studies. Two APS detectors, namely Vanilla and Large Area Sensor (LAS), were developed by the Multidimensional Integrated Intelligent Imaging (MI-3) consortium to cover a range of scientific applications including x-ray diffraction. The MI-3 Plus consortium developed a novel large area APS, named as Dynamically Adjustable Medical Imaging Technology (DynAMITe), to combine the key characteristics of Vanilla and LAS with a number of extra features. The active area (12.8 × 13.1 cm 2) of DynaMITe offers the ability of angle dispersive x-ray diffraction (ADXRD). The current study demonstrates the feasibility of using DynaMITe for breast cancer diagnosis by identifying six breast-equivalent plastics. Further work will be done to optimize the system in order to perform ADXRD for identification of suspicious areas of breast tissue following a conventional mammogram taken with the same sensor. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).</p

    Radiation hardness of a large area CMOS active pixel sensor for bio-medical application

    No full text
    A wafer scale CMOS Active Pixel Sensor has been designed employing design techniques of transistor enclosed geometry and P+ doped guard rings to offer ionizing radiation tolerance. The detector was irradiated with 160 kVp X-rays up to a total dose of 94 kGy(Si) and remained functional. The radiation damage produced in the device has been studied, resulting in a dark current density increase per decade of 96±5 pA/cm2/decade and a damage threshold of 204 Gy(Si). The damage produced in the detector has been compared with a commercially available CMOS APS, showing a radiation tolerance about 100 times higher. Moreover Monte Carlo simulations have been performed to evaluate primary and secondary energy deposition in each of the detector stages. © 2012 IEEE.</p

    14 C autoradiography with a novel wafer scale CMOS Active Pixel Sensor

    No full text
    14 C autoradiography is a well established technique for structural and metabolic analysis of cells and tissues. The most common detection medium for this application is film emulsion, which offers unbeatable spatial resolution due to its fine granularity but at the same time has some limiting drawbacks such as poor linearity and rapid saturation. In recent years several digital detectors have been developed, following the technological transition from analog to digital-based detection systems in the medical and biological field. Even so such digital systems have been greatly limited by the size of their active area (a few square centimeters), which have made them unsuitable for routine use in many biological applications where sample areas are typically ~ 10–100 cm 2 . The Multidimensional Integrated Intelligent Imaging (MI3-Plus) consortium has recently developed a new large area CMOS Active Pixel Sensor (12.8 cm × 13.1 cm). This detector, based on the use of two different pixel resolutions, is capable of providing simultaneously low noise and high dynamic range on a wafer scale. In this paper we will demonstrate the suitability of this detector for routine beta autoradiography in a comparative approach with widely used film emulsion.</p

    Using a large area CMOS APS for direct chemiluminescence detection in western blotting electrophoresis

    No full text
    Western blotting electrophoretic sequencing is an analytical technique widely used in Functional Proteomics to detect, recognize and quantify specific labelled proteins in biological samples. A commonly used label for western blotting is Enhanced ChemiLuminescence (ECL) reagents based on fluorescent light emission of Luminol at 425nm. Film emulsion is the conventional detection medium, but is characterized by non-linear response and limited dynamic range. Several western blotting digital imaging systems have being developed, mainly based on the use of cooled Charge Coupled Devices (CCDs) and single avalanche diodes that address these issues. Even so these systems present key drawbacks, such as a low frame rate and require operation at low temperature. Direct optical detection using Complementary Metal Oxide Semiconductor (CMOS) Active Pixel Sensors (APS) could represent a suitable digital alternative for this application. In this paper the authors demonstrate the viability of direct chemiluminescent light detection in western blotting electrophoresis using a CMOS APS at room temperature. Furthermore, in recent years, improvements in fabrication techniques have made available reliable processes for very large imagers, which can be now scaled up to wafer size, allowing direct contact imaging of full size western blotting samples. We propose using a novel wafer scale APS (12.8 cm�13.2 cm), with an array architecture using two different pixel geometries that can deliver an inherently low noise and high dynamic range image at the same time representing a dramatic improvement with respect to the current western blotting imaging systems. © 2012 SPIE.</p

    DynAMITe: A prototype large area CMOS APS for breast cancer diagnosis using x-ray diffraction measurements

    No full text
    X-ray diffraction studies are used to identify specific materials. Several laboratory-based x-ray diffraction studies were made for breast cancer diagnosis. Ideally a large area, low noise, linear and wide dynamic range digital x-ray detector is required to perform x-ray diffraction measurements. Recently, digital detectors based on Complementary Metal-Oxide- Semiconductor (CMOS) Active Pixel Sensor (APS) technology have been used in x-ray diffraction studies. Two APS detectors, namely Vanilla and Large Area Sensor (LAS), were developed by the Multidimensional Integrated Intelligent Imaging (MI-3) consortium to cover a range of scientific applications including x-ray diffraction. The MI-3 Plus consortium developed a novel large area APS, named as Dynamically Adjustable Medical Imaging Technology (DynAMITe), to combine the key characteristics of Vanilla and LAS with a number of extra features. The active area (12.8 � 13.1 cm 2) of DynaMITe offers the ability of angle dispersive x-ray diffraction (ADXRD). The current study demonstrates the feasibility of using DynaMITe for breast cancer diagnosis by identifying six breast-equivalent plastics. Further work will be done to optimize the system in order to perform ADXRD for identification of suspicious areas of breast tissue following a conventional mammogram taken with the same sensor. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).</p

    Using a large area CMOS APS for direct chemiluminescence detection in western blotting electrophoresis

    No full text
    Western blotting electrophoretic sequencing is an analytical technique widely used in Functional Proteomics to detect, recognize and quantify specific labelled proteins in biological samples. A commonly used label for western blotting is Enhanced ChemiLuminescence (ECL) reagents based on fluorescent light emission of Luminol at 425nm. Film emulsion is the conventional detection medium, but is characterized by non-linear response and limited dynamic range. Several western blotting digital imaging systems have being developed, mainly based on the use of cooled Charge Coupled Devices (CCDs) and single avalanche diodes that address these issues. Even so these systems present key drawbacks, such as a low frame rate and require operation at low temperature. Direct optical detection using Complementary Metal Oxide Semiconductor (CMOS) Active Pixel Sensors (APS) could represent a suitable digital alternative for this application. In this paper the authors demonstrate the viability of direct chemiluminescent light detection in western blotting electrophoresis using a CMOS APS at room temperature. Furthermore, in recent years, improvements in fabrication techniques have made available reliable processes for very large imagers, which can be now scaled up to wafer size, allowing direct contact imaging of full size western blotting samples. We propose using a novel wafer scale APS (12.8 cm�13.2 cm), with an array architecture using two different pixel geometries that can deliver an inherently low noise and high dynamic range image at the same time representing a dramatic improvement with respect to the current western blotting imaging systems. © 2012 SPIE.</p
    corecore