7,491 research outputs found
Using b-tagging to enhance the SUSY reach of the CERN Large Hadron Collider
Assuming that supersymmetry is realized with parameters in the hyperbolic
branch/focus point (HB/FP) region of the minimal supergravity (mSUGRA) model,
we show that by searching for multijet + missing E_T events with tagged b jets
the reach of experiments at the LHC may be extended by as much as 20% from
current projections. The reason for this is that gluino decays to third
generation quarks are enhanced because the lightest neutralino has substantial
higgsino components. Although we were motivated to perform this analysis
because the HB/FP region is compatible with the recent determination of the
relic density of cold dark matter, our considerations may well have a wider
applicability since decays of gluinos to third generation quarks are favoured
in a wide variety of models.Comment: 16 pages, 1 figur
Diphoton Signals for Large Extra Dimensions at the Tevatron and CERN LHC
We analyze the potentiality of hadron colliders to search for large extra dimensions via the production of photon pairs. The virtual exchange of Kaluza--Klein gravitons can significantly enhance this processes provided the quantum gravity scale () is in the TeV range. We studied in detail the subprocesses and taking into account the complete Standard Model and graviton contributions as well as the unitarity constraints. We show that the Tevatron Run II will be able to probe up to 1.5--1.9 TeV at 2 level, while the LHC can extend this search to 5.3--6.7 TeV, depending on the number of extra dimensions
Tapentadol in cancer pain management: a prospective open-label study.
OBJECTIVES:
The aim of this prospective, open-label study was to evaluate the efficacy and tolerability of tapentadol (TP) in the management of cancer pain.
METHODS:
A 4 weeks' prospective study was carried out in 50 opioid-naive cancer patients with moderate-severe pain. Each patient initially received twice-daily doses of slow-release TP 50 mg. Doses were then managed to maintain adequate relief or dose-limiting toxicity, on the basis of the clinical response. The following parameters were recorded at weekly intervals for 4 weeks: pain and opioid-related adverse effects, quality of life measured with the Spitzer score, TP escalation index percent (TPEI%) and TP escalation index in mg (TPEImg), calculated at the end of the study, pain mechanisms, and PainDETECT at baseline.
RESULTS:
Of 50 patients, 39 completed the entire study and 11 discontinued the treatment for different reasons. Pain intensity significantly decreased from baseline to all the week intervals (p < 0.0005), and adverse effects did not changed significantly, while quality of life improved. TP escalation indexes were low and no relationship was found with age, gender, and pain mechanisms.
CONCLUSION:
Tapentalol started in doses of 100 mg/day was well-tolerated and effective in opioid-naive patients with cancer pain, regardless of the pain mechanism. It can be considered as a flexible drug to be used in patients with moderate-severe pain.
LIMITATIONS:
This was an open-label study for exploratory purposes. Data should be confirmed in controlled studies with a larger number of patient
Quartic Anomalous Couplings in Colliders
We study the constraints on the vertices ,
, and that can be obtained from
triple-gauge-boson production at the next generation of linear
colliders operating in the mode. We analyze the processes
(, or ) and show that these reactions
increase the potential of machines to search for anomalous
four-gauge-boson interactions.Comment: 15 pages, Latex file using ReVteX, 4 uufiled figures include
Epidemiology and Characteristics of Episodic Breathlessness in Advanced Cancer Patients: An Observational Study
CONTEXT:
Episodic breathlessness is a relevant aspect in patients with advanced cancer.
OBJECTIVES:
The aim of this study was to assess the different aspects of this clinical phenomenon.
METHODS:
A consecutive sample of patients with advanced cancer admitted to different settings for a period of six months was surveyed. The presence of background breathlessness and episodic breathlessness, their intensity (numerical scale 0-10), and drugs used for treatment were collected. Factors inducing episodic breathlessness and its influence on daily activities were investigated.
RESULTS:
Of 921 patients, 29.3% (n = 269) had breathlessness and 134 patients (49.8%) were receiving drugs for background breathlessness. In the multivariate analysis, the risk of breathlessness increased with chronic obstructive pulmonary disease, although it decreased in patients receiving disease-oriented therapy and patients with gastrointestinal tumors. The prevalence of episodic breathlessness was 70.9% (n = 188), and its mean intensity was 7.1 (SD 1.6). The mean duration of untreated episodic breathlessness was 19.9 minutes (SD 35.3); 41% of these patients were receiving drugs for episodic breathlessness. The majority of episodic breathlessness events (88.2%) were triggered by activity. In the multivariate analysis, higher Karnofsky Performance Status levels were significantly related to episodic breathlessness, although patients receiving disease-oriented therapy were less likely to have episodic breathlessness.
CONCLUSION:
This study showed that episodic breathlessness frequently occurs in patients with breathlessness in the advanced stage of disease, has a severe intensity, and is characterized by rapid onset and short duration, which require rapid measures
Sneutrino Mass Measurements at e+e- Linear Colliders
It is generally accepted that experiments at an e+e- linear colliders will be
able to extract the masses of the selectron as well as the associated
sneutrinos with a precision of ~ 1% by determining the kinematic end points of
the energy spectrum of daughter electrons produced in their two body decays to
a lighter neutralino or chargino. Recently, it has been suggested that by
studying the energy dependence of the cross section near the production
threshold, this precision can be improved by an order of magnitude, assuming an
integrated luminosity of 100 fb^-1. It is further suggested that these
threshold scans also allow the masses of even the heavier second and third
generation sleptons and sneutrinos to be determined to better than 0.5%. We
re-examine the prospects for determining sneutrino masses. We find that the
cross sections for the second and third generation sneutrinos are too small for
a threshold scan to be useful. An additional complication arises because the
cross section for sneutrino pair to decay into any visible final state(s)
necessarily depends on an unknown branching fraction, so that the overall
normalization in unknown. This reduces the precision with which the sneutrino
mass can be extracted. We propose a different strategy to optimize the
extraction of m(\tilde{\nu}_\mu) and m(\tilde{\nu}_\tau) via the energy
dependence of the cross section. We find that even with an integrated
luminosity of 500 fb^-1, these can be determined with a precision no better
than several percent at the 90% CL. We also examine the measurement of
m(\tilde{\nu}_e) and show that it can be extracted with a precision of about
0.5% (0.2%) with an integrated luminosity of 120 fb^-1 (500 fb^-1).Comment: RevTex, 46 pages, 15 eps figure
Phenomenological Aspects of Gauge Mediation with Sequestered Supersymmetry Breaking in light of Dark Matter Detection
In a recent work, a model of gauge mediation with sequestered supersymmetry
(SUSY) breaking was proposed. In this model, the mass of the gravitino is
O(100) GeV without causing the flavor-changing neutral-current problem. In
contrast to traditional gauge mediation, the gravitino is not the lightest SUSY
particle and the neutralino is the candidate of the dark matter. In this paper,
we investigate phenomenological aspects of this model and discuss the
possibility of the direct detection of the dark matter. In particular, we focus
on the light neutralino case and find that the light-Higgsino scenario such as
the focus point is interesting, taking account of the recent CDMS result.Comment: 17 pages, 8 figures; v2:references added, some corrections;
v3:version accepted for publication in JHE
Direct Signals for Large Extra Dimensions in the Production of Fermion Pairs at Linear Colliders
We analyze the potentiality of the new generation of linear
colliders to search for large extra dimensions via the production of fermion
pairs in association with Kaluza-Klein gravitons (G), i.e. . This process leads to a final state exhibiting a significant amount
of missing energy in addition to acoplanar lepton or jet pairs. We study in
detail this reaction using full tree level contibutions due to the graviton
emission and the standard model backgrounds. After choosing the cuts to enhance
the signal, we show that a linear collider with a center-of-mass energy of 500
GeV will be able to probe quantum gravity scales from 0.96(0.86) up to 4.1(3.3)
TeV at 2(5) level, depending on the number of extra dimensions.Comment: 19 pages, 5 figures. Using RevTex, axodraw.sty. Discussion was
extended. No changes in the results. Accepted for publication by Phys. Rev.
- …