252 research outputs found
Precision Crystal Calorimetry in High Energy Physics
Crystal Calorimetry is widely used in high energy physics because of its
precision. Recent development in crystal technology identified two key issues
to reach and maintain crystal precision: light response uniformity and
calibration in situ. Crystal radiation damage is understood. While the damage
in alkali halides is found to be caused by the oxygen/hydroxyl contamination,
it is the structure defects, such as oxygen vacancies, cause damage in oxides.Comment: 8 pages with 13 eps Figures, RevTe
Local Metric Learning in 2D/3D Deformable Registration With Application in the Abdomen
In image-guided radiotherapy (IGRT) of disease sites subject to respiratory motion, soft tissue deformations can affect localization accuracy. We describe the application of a method of 2D/3D deformable registration to soft tissue localization in abdomen. The method, called registration efficiency and accuracy through learning a metric on shape (REALMS), is designed to support real-time IGRT. In a previously developed version of REALMS, the method interpolated 3D deformation parameters for any credible deformation in a deformation space using a single globally-trained Riemannian metric for each parameter. We propose a refinement of the method in which the metric is trained over a particular region of the deformation space, such that interpolation accuracy within that region is improved. We report on the application of the proposed algorithm to IGRT in abdominal disease sites, which is more challenging than in lung because of low intensity contrast and nonrespiratory deformation. We introduce a rigid translation vector to compensate for nonrespiratory deformation, and design a special region-of-interest around fiducial markers implanted near the tumor to produce a more reliable registration. Both synthetic data and actual data tests on abdominal datasets show that the localized approach achieves more accurate 2D/3D deformable registration than the global approach
Recommended from our members
AAPM medical physics practice guideline 10.a.: Scope of practice for clinical medical physics.
The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline (MPPG) represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiation requires specific training, skills, and techniques as described in each document. As the review of the previous version of AAPM Professional Policy (PP)-17 (Scope of Practice) progressed, the writing group focused on one of the main goals: to have this document accepted by regulatory and accrediting bodies. After much discussion, it was decided that this goal would be better served through a MPPG. To further advance this goal, the text was updated to reflect the rationale and processes by which the activities in the scope of practice were identified and categorized. Lastly, the AAPM Professional Council believes that this document has benefitted from public comment which is part of the MPPG process but not the AAPM Professional Policy approval process. The following terms are used in the AAPM's MPPGs: Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances
2D/3D image registration using regression learning
In computer vision and image analysis, image registration between 2D projections and a 3D image that achieves high accuracy and near real-time computation is challenging. In this paper, we propose a novel method that can rapidly detect an object’s 3D rigid motion or deformation from a 2D projection image or a small set thereof. The method is called CLARET (Correction via Limited-Angle Residues in External Beam Therapy) and consists of two stages: registration preceded by shape space and regression learning. In the registration stage, linear operators are used to iteratively estimate the motion/deformation parameters based on the current intensity residue between the target projec-tion(s) and the digitally reconstructed radiograph(s) (DRRs) of the estimated 3D image. The method determines the linear operators via a two-step learning process. First, it builds a low-order parametric model of the image region’s motion/deformation shape space from its prior 3D images. Second, using learning-time samples produced from the 3D images, it formulates the relationships between the model parameters and the co-varying 2D projection intensity residues by multi-scale linear regressions. The calculated multi-scale regression matrices yield the coarse-to-fine linear operators used in estimating the model parameters from the 2D projection intensity residues in the registration. The method’s application to Image-guided Radiation Therapy (IGRT) requires only a few seconds and yields good results in localizing a tumor under rigid motion in the head and neck and under respiratory deformation in the lung, using one treatment-time imaging 2D projection or a small set thereof
Algorithm and performance of a clinical IMRT beam-angle optimization system
This paper describes the algorithm and examines the performance of an IMRT
beam-angle optimization (BAO) system. In this algorithm successive sets of beam
angles are selected from a set of predefined directions using a fast simulated
annealing (FSA) algorithm. An IMRT beam-profile optimization is performed on
each generated set of beams. The IMRT optimization is accelerated by using a
fast dose calculation method that utilizes a precomputed dose kernel. A compact
kernel is constructed for each of the predefined beams prior to starting the
FSA algorithm. The IMRT optimizations during the BAO are then performed using
these kernels in a fast dose calculation engine. This technique allows the IMRT
optimization to be performed more than two orders of magnitude faster than a
similar optimization that uses a convolution dose calculation engine.Comment: Final version that appeared in Phys. Med. Biol. 48 (2003) 3191-3212.
Original EPS figures have been converted to PNG files due to size limi
Constraints on Variant Axion Models
A particular class of variant axion models with two higgs doublets and a
singlet is studied. In these models the axion couples either to the -quark
or -quark or both, but not to , , , or . When the axion couples
to only one quark the models possess the desirable feature of having no domain
wall problem, which makes them viable candidates for a cosmological axion
string scenario. We calculate the axion couplings to leptons, photons and
nucleons, and the astrophysical constraints on the axion decay constant
are investigated and compared to the DFSZ axion model. We find that the most
restrictive lower bound on , that from SN1987a, is lowered by up to a
factor of about 30, depending on the model and also the ratio of the vacuum
expectation values of the higgs doublets. For scenarios with axionic strings,
the allowed window for in the quark model can be more than two orders
of magnitude. For inflationary scenarios, the cosmological upper bound on
, where is the QCD anomaly factor, is unaffected: however, the
variant models have either 3 or 6 times smaller than the DFSZ model.Comment: 21pp RevTeX, 1 eps fig, uses graphics style, typo corrected, and
corrected file sent this time. To appear in Physical Review
A fluence convolution method to account for respiratory motion in three‐dimensional dose calculations of the liver: A Monte Carlo study
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/134815/1/mp1412.pd
- …