1,136 research outputs found
Angular Reconstruction of a Lead Scintillating-Fiber Sandwiched Electromagnetic Calorimeter
A new method called Neighbor Cell Deposited Energy Ratio (NCDER) is proposed
to reconstruct incidence position in a single layer for a 3-dimensional imaging
electromagnetic calorimeter (ECAL).This method was applied to reconstruct the
ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The
results show that this method can achieve an angular resolution of 7.36\pm 0.08
/ \sqrt(E) \oplus 0.28 \pm 0.02 degree in the determination of the photons
direction, which is much more precise than that obtained with the
commonly-adopted Center of Gravity(COG) method (8.4 \pm 0.1 /sqrt(E) \oplus
0.8\pm0.3 degree). Furthermore, since it uses only the properties of
electromagnetic showers, this new method could also be used for other type of
fine grain sampling calorimeters.Comment: 6 pages, 8 figure
Multifractal characterisation of length sequences of coding and noncoding segments in a complete genome
The coding and noncoding length sequences constructed from a complete genome
are characterised by multifractal analysis. The dimension spectrum and
its derivative, the 'analogous' specific heat , are calculated for the
coding and noncoding length sequences of bacteria, where is the moment
order of the partition sum of the sequences. From the shape of the
and curves, it is seen that there exists a clear difference between the
coding/noncoding length sequences of all organisms considered and a completely
random sequence. The complexity of noncoding length sequences is higher than
that of coding length sequences for bacteria. Almost all curves for
coding length sequences are flat, so their multifractality is small whereas
almost all curves for noncoding length sequences are multifractal-like.
We propose to characterise the bacteria according to the types of the
curves of their noncoding length sequences.Comment: 15 pages with 5 figures, Latex, Accepted for publication in Physica
Measure representation and multifractal analysis of complete genomes
This paper introduces the notion of measure representation of DNA sequences.
Spectral analysis and multifractal analysis are then performed on the measure
representations of a large number of complete genomes. The main aim of this
paper is to discuss the multifractal property of the measure representation and
the classification of bacteria. From the measure representations and the values
of the spectra and related curves, it is concluded that these
complete genomes are not random sequences. In fact, spectral analyses performed
indicate that these measure representations considered as time series, exhibit
strong long-range correlation. For substrings with length K=8, the
spectra of all organisms studied are multifractal-like and sufficiently smooth
for the curves to be meaningful. The curves of all bacteria
resemble a classical phase transition at a critical point. But the 'analogous'
phase transitions of chromosomes of non-bacteria organisms are different. Apart
from Chromosome 1 of {\it C. elegans}, they exhibit the shape of double-peaked
specific heat function.Comment: 12 pages with 9 figures and 1 tabl
Tunable flat band slow light in reconfigurable photonic crystal waveguides based on magnetic fluids
The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches
The CDEX Collaboration has been established for direct detection of light
dark matter particles, using ultra-low energy threshold p-type point-contact
germanium detectors, in China JinPing underground Laboratory (CJPL). The first
1 kg point-contact germanium detector with a sub-keV energy threshold has been
tested in a passive shielding system located in CJPL. The outputs from both the
point-contact p+ electrode and the outside n+ electrode make it possible to
scan the lower energy range of less than 1 keV and at the same time to detect
the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode
may also provide a more powerful method for signal discrimination for dark
matter experiment. Some key parameters, including energy resolution, dead time,
decay times of internal X-rays, and system stability, have been tested and
measured. The results show that the 1 kg point-contact germanium detector,
together with its shielding system and electronics, can run smoothly with good
performances. This detector system will be deployed for dark matter search
experiments.Comment: 6 pages, 8 figure
Correlation property of length sequences based on global structure of complete genome
This paper considers three kinds of length sequences of the complete genome.
Detrended fluctuation analysis, spectral analysis, and the mean distance
spanned within time are used to discuss the correlation property of these
sequences. The values of the exponents from these methods of these three kinds
of length sequences of bacteria indicate that the long-range correlations exist
in most of these sequences. The correlation have a rich variety of behaviours
including the presence of anti-correlations. Further more, using the exponent
, it is found that these correlations are all linear (). It is also found that these sequences exhibit noise in some
interval of frequency (). The length of this interval of frequency depends
on the length of the sequence. The shape of the periodogram in exhibits
some periodicity. The period seems to depend on the length and the complexity
of the length sequence.Comment: RevTex, 9 pages with 5 figures and 3 tables. Phys. Rev. E Jan. 1,2001
(to appear
- …
