1,136 research outputs found

    Angular Reconstruction of a Lead Scintillating-Fiber Sandwiched Electromagnetic Calorimeter

    Full text link
    A new method called Neighbor Cell Deposited Energy Ratio (NCDER) is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL).This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36\pm 0.08 / \sqrt(E) \oplus 0.28 \pm 0.02 degree in the determination of the photons direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity(COG) method (8.4 \pm 0.1 /sqrt(E) \oplus 0.8\pm0.3 degree). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.Comment: 6 pages, 8 figure

    Multifractal characterisation of length sequences of coding and noncoding segments in a complete genome

    Full text link
    The coding and noncoding length sequences constructed from a complete genome are characterised by multifractal analysis. The dimension spectrum DqD_{q} and its derivative, the 'analogous' specific heat CqC_{q}, are calculated for the coding and noncoding length sequences of bacteria, where qq is the moment order of the partition sum of the sequences. From the shape of the % D_{q} and CqC_{q} curves, it is seen that there exists a clear difference between the coding/noncoding length sequences of all organisms considered and a completely random sequence. The complexity of noncoding length sequences is higher than that of coding length sequences for bacteria. Almost all DqD_{q} curves for coding length sequences are flat, so their multifractality is small whereas almost all DqD_{q} curves for noncoding length sequences are multifractal-like. We propose to characterise the bacteria according to the types of the CqC_{q} curves of their noncoding length sequences.Comment: 15 pages with 5 figures, Latex, Accepted for publication in Physica

    Measure representation and multifractal analysis of complete genomes

    Get PDF
    This paper introduces the notion of measure representation of DNA sequences. Spectral analysis and multifractal analysis are then performed on the measure representations of a large number of complete genomes. The main aim of this paper is to discuss the multifractal property of the measure representation and the classification of bacteria. From the measure representations and the values of the DqD_{q} spectra and related CqC_{q} curves, it is concluded that these complete genomes are not random sequences. In fact, spectral analyses performed indicate that these measure representations considered as time series, exhibit strong long-range correlation. For substrings with length K=8, the DqD_{q} spectra of all organisms studied are multifractal-like and sufficiently smooth for the CqC_{q} curves to be meaningful. The CqC_{q} curves of all bacteria resemble a classical phase transition at a critical point. But the 'analogous' phase transitions of chromosomes of non-bacteria organisms are different. Apart from Chromosome 1 of {\it C. elegans}, they exhibit the shape of double-peaked specific heat function.Comment: 12 pages with 9 figures and 1 tabl

    The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches

    Full text link
    The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.Comment: 6 pages, 8 figure

    Correlation property of length sequences based on global structure of complete genome

    Get PDF
    This paper considers three kinds of length sequences of the complete genome. Detrended fluctuation analysis, spectral analysis, and the mean distance spanned within time LL are used to discuss the correlation property of these sequences. The values of the exponents from these methods of these three kinds of length sequences of bacteria indicate that the long-range correlations exist in most of these sequences. The correlation have a rich variety of behaviours including the presence of anti-correlations. Further more, using the exponent γ\gamma, it is found that these correlations are all linear (γ=1.0±0.03\gamma=1.0\pm 0.03). It is also found that these sequences exhibit 1/f1/f noise in some interval of frequency (f>1f>1). The length of this interval of frequency depends on the length of the sequence. The shape of the periodogram in f>1f>1 exhibits some periodicity. The period seems to depend on the length and the complexity of the length sequence.Comment: RevTex, 9 pages with 5 figures and 3 tables. Phys. Rev. E Jan. 1,2001 (to appear
    corecore