6,044 research outputs found

    Experimental Techniques

    Get PDF

    Experimental application of sum rules for electron energy loss magnetic chiral dichroism

    Full text link
    We present a derivation of the orbital and spin sum rules for magnetic circular dichroic spectra measured by electron energy loss spectroscopy in a transmission electron microscope. These sum rules are obtained from the differential cross section calculated for symmetric positions in the diffraction pattern. Orbital and spin magnetic moments are expressed explicitly in terms of experimental spectra and dynamical diffraction coefficients. We estimate the ratio of spin to orbital magnetic moments and discuss first experimental results for the Fe L_{2,3} edge.Comment: 11 pages, 2 figure

    Energy-loss magnetic chiral dichroism (EMCD): Magnetic chiral dichroism in the electron microscope

    Get PDF
    A new technique called energy-loss magnetic chiral dichroism (EMCD) has recently been developed [P. Schattschneider, et al. Nature 441, 486 (2006)] to measure magnetic circular dichroism in the transmission electron microscope (TEM) with a spatial resolution of 10 nm. This novel technique is the TEM counterpart of x-ray magnetic circular dichroism, which is widely used for the characterization of magnetic materials with synchrotron radiation. In this paper we describe several experimental methods that can be used to measure the EMCD signal [P. Schattschneider, et al. Nature 441, 486 (2006); C. Hébert, et al. Ultramicroscopy 108(3), 277 (2008); B. Warot-Fonrose, et al. Ultramicroscopy 108(5), 393 (2008); L. Calmels, et al. Phys. Rev. B 76, 060409 (2007); P. van Aken, et al. Microsc. Microanal. 13(3), 426 (2007)] and give a review of the recent improvements of this new investigation tool. The dependence of the EMCD on several experimental conditions (such as thickness, relative orientation of beam and sample, collection and convergence angle) is investigated in the transition metals iron, cobalt, and nickel. Different scattering geometries are illustrated; their advantages and disadvantages are detailed, together with current limitations. The next realistic perspectives of this technique consist of measuring atomic specific magnetic moments, using suitable spin and orbital sum rules, [L. Calmels, et al. Phys. Rev. B 76, 060409 (2007); J. Rusz, et al. Phys. Rev. B 76, 060408 (2007)] with a resolution down to 2 to 3 n

    The Minimal Supersymmetric Standard Model: Group Summary Report

    Get PDF
    CONTENTS: 1. Synopsis, 2. The MSSM Spectrum, 3. The Physical Parameters, 4. Higgs Boson Production and Decays, 5. SUSY Particle Production and Decays, 6. Experimental Bounds on SUSY Particle Masses, 7. References.Comment: 121 pages, latex + epsfig, graphicx, axodraw, Report of the MSSM working group for the Workshop "GDR-Supersym\'etrie",France. Rep. PM/98-4

    Determination of the branching ratios Γ(KL3π0)/Γ(KLπ+ππ0)\Gamma (K_L \to 3 \pi^0) / \Gamma (K_L \to \pi^+ \pi^- \pi^0) and Γ(KL3π0)/Γ(KLπeν)\Gamma (K_L \to 3 \pi^0) / \Gamma (K_L \to \pi e \nu )

    Get PDF
    Improved branching ratios were measured for the KL3π0K_L \to 3 \pi^0 decay in a neutral beam at the CERN SPS with the NA31 detector: Γ(KL3π0)/Γ(KLπ+ππ0)=1.611±0.037\Gamma (K_L \to 3 \pi^0) / \Gamma (K_L \to \pi^+ \pi^- \pi^0) = 1.611 \pm 0.037 and Γ(KL3π0)/Γ(KLπeν)=0.545±0.010\Gamma (K_L \to 3 \pi^0) / \Gamma (K_L \to \pi e \nu ) = 0.545 \pm 0.010. From the first number an upper limit for ΔI=5/2\Delta I =5/2 and ΔI=7/2\Delta I = 7/2 transitions in neutral kaon decay is derived. Using older results for the Ke3/Kμ\mu 3 fraction, the 3π0\pi^0 branching ratio is found to be Γ(KL3π0)/Γtot=(0.211±0.003)\Gamma (K_L \to 3 \pi^0 )/ \Gamma_{tot} = (0.211 \pm 0.003), about a factor three more precise than from previous experiments

    Energy Linearity and Resolution of the ATLAS Electromagnetic Barrel Calorimeter in an Electron Test-Beam

    Get PDF
    A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to 245 GeV. The electron beam impinged at one point corresponding to a pseudo-rapidity of eta=0.687 and an azimuthal angle of phi=0.28 in the ATLAS coordinate system. A detailed study of several effects biasing the electron energy measurement allowed an energy reconstruction procedure to be developed that ensures a good linearity and a good resolution. Use is made of detailed Monte Carlo simulations based on Geant which describe the longitudinal and transverse shower profiles as well as the energy distributions. For electron energies between 15 GeV and 180 GeV the deviation of the measured incident electron energy over the beam energy is within 0.1%. The systematic uncertainty of the measurement is about 0.1% at low energies and negligible at high energies. The energy resolution is found to be about 10% sqrt(E) for the sampling term and about 0.2% for the local constant term

    Position resolution and particle identification with the ATLAS EM calorimeter

    Full text link
    In the years between 2000 and 2002 several pre-series and series modules of the ATLAS EM barrel and end-cap calorimeter were exposed to electron, photon and pion beams. The performance of the calorimeter with respect to its finely segmented first sampling has been studied. The polar angle resolution has been found to be in the range 50-60 mrad/sqrt(E (GeV)). The neutral pion rejection has been measured to be about 3.5 for 90% photon selection efficiency at pT=50 GeV/c. Electron-pion separation studies have indicated that a pion fake rate of (0.07-0.5)% can be achieved while maintaining 90% electron identification efficiency for energies up to 40 GeV.Comment: 32 pages, 22 figures, to be published in NIM

    Measurement of Neutrino-Electron Scattering Cross-Section with a CsI(Tl) Scintillating Crystal Array at the Kuo-Sheng Nuclear Power Reactor

    Full text link
    The νˉee\bar{\nu}_{e}-e^{-} elastic scattering cross-section was measured with a CsI(Tl) scintillating crystal array having a total mass of 187kg. The detector was exposed to an average reactor νˉe\bar{\nu}_{e} flux of 6.4×1012 cm2s1\rm{6.4\times 10^{12} ~ cm^{-2}s^{-1}} at the Kuo-Sheng Nuclear Power Station. The experimental design, conceptual merits, detector hardware, data analysis and background understanding of the experiment are presented. Using 29882/7369 kg-days of Reactor ON/OFF data, the Standard Model(SM) electroweak interaction was probed at the squared 4-momentum transfer range of Q23×106 GeV2\rm{Q^2 \sim 3 \times 10^{-6} ~ GeV^2}. The ratio of experimental to SM cross-sections of ξ=[1.08±0.21(stat)±0.16(sys)] \xi =[ 1.08 \pm 0.21(stat)\pm 0.16(sys)] was measured. Constraints on the electroweak parameters (gV,gA)(g_V , g_A) were placed, corresponding to a weak mixing angle measurement of \s2tw = 0.251 \pm 0.031({\it stat}) \pm 0.024({\it sys}) . Destructive interference in the SM \nuebar -e process was verified. Bounds on anomalous neutrino electromagnetic properties were placed: neutrino magnetic moment at \mu_{\nuebar}< 2.2 \times 10^{-10} \mu_{\rm B} and the neutrino charge radius at -2.1 \times 10^{-32} ~{\rm cm^{2}} < \nuchrad < 3.3 \times 10^{-32} ~{\rm cm^{2}}, both at 90% confidence level.Comment: 18 Figures, 7 Tables; published version as V2 with minor revision from V
    corecore