2,688 research outputs found
GRAVITY: the Calibration Unit
We present in this paper the design and characterisation of a new sub-system
of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The
Calibration Unit provides all functions to test and calibrate the beam combiner
instrument: it creates two artificial stars on four beams, and dispose of four
delay lines with an internal metrology. It also includes artificial stars for
the tip-tilt and pupil guiding systems, as well as four metrology pick-up
diodes, for tests and calibration of the corresponding sub-systems. The
calibration unit also hosts the reference targets to align GRAVITY to the VLTI,
and the safety shutters to avoid the metrology light to propagate in the
VLTI-lab. We present the results of the characterisation and validtion of these
differrent sub-units.Comment: 12 pages, 11 figures. Proceeding of SPIE 9146 "Optical and Infrared
Interferometry IV
The GRAVITY metrology system: modeling a metrology in optical fibers
GRAVITY is the second generation VLT Interferometer (VLTI) instrument for
high-precision narrow-angle astrometry and phase-referenced interferometric
imaging. The laser metrology system of GRAVITY is at the heart of its
astrometric mode, which must measure the distance of 2 stars with a precision
of 10 micro-arcseconds. This means the metrology has to measure the optical
path difference between the two beam combiners of GRAVITY to a level of 5 nm.
The metrology design presents some non-common paths that have consequently to
be stable at a level of 1 nm. Otherwise they would impact the performance of
GRAVITY. The various tests we made in the past on the prototype give us hints
on the components responsible for this error, and on their respective
contribution to the total error. It is however difficult to assess their exact
origin from only OPD measurements, and therefore, to propose a solution to this
problem. In this paper, we present the results of a semi-empirical modeling of
the fibered metrology system, relying on theoretical basis, as well as on
characterisations of key components. The modeling of the metrology system
regarding various effects, e.g., temperature, waveguide heating or mechanical
stress, will help us to understand how the metrology behave. The goals of this
modeling are to 1) model the test set-ups and reproduce the measurements (as a
validation of the modeling), 2) determine the origin of the non-common path
errors, and 3) propose modifications to the current metrology design to reach
the required 1nm stability.Comment: 20 pages, 19 figures. Proceeding of SPIE 9146 "Optical and Infrared
Interferometry IV
Cognitive improvement in patients with carotid stenosis is independent of treatment type
Treatment of carotid artery stenosis decreases the long-term risk of stroke and may enhance cerebral blood flow. It is therefore expected to have the potential to prevent cognitive decline or even improve cognition over the long-term. However, intervention itself can cause peri-interventional cerebral infarcts, possibly resulting in a decline of cognitive performance, at least for a short time. We investigated the long-term effects of three treatment methods on cognition and the emotional state one year after intervention. In this prospective observational cohort study, 58 patients with extracranial carotid artery stenosis (≥ 70%) underwent magnetic resonance imaging and assessment of cognition, mood and motor speed before carotid endarterectomy (n = 20), carotid stenting (n = 10) or best medical treatment (n = 28) (i.e., time-point 1 [TP1]), and at one-year follow-up (TP2). Gain scores, reflecting cognitive change after treatment, were built according to performance as (TP2 -TP1)/TP1. Independent of the treatment type, significant improvement in frontal lobe functions, visual memory and motor speed was found. Performance level, motor speed and mood at TP1 were negatively correlated with gain scores, with greater improvement in patients with low performance before treatment. Active therapy, whether conservative or interventional, produces significant improvement of frontal lobe functions and memory in patients with carotid artery disease, independent of treatment type. This effect was particularly pronounced in patients with low cognitive performance prior to treatment
Cognitive and emotional effects of carotid stenosis.
PRINCIPLES: Patients with carotid artery stenosis (CAS) are at risk of ipsilateral stroke and chronic compromise of cerebral blood flow. It is under debate whether the hypo-perfusion or embolism in CAS is directly related to cognitive impairment. Alternatively, CAS may be a marker for underlying risk factors, which themselves influence cognition. We aimed to determine cognitive performance level and the emotional state of patients with CAS. We hypo-thesised that patients with high grade stenosis, bilateral stenosis, symptomatic patients and/or those with relevant risk factors would suffer impairment of their cognitive performance and emotional state.
METHODS: A total of 68 patients with CAS of ≥70% were included in a prospective exploratory study design. All patients underwent structured assessment of executive functions, language, verbal and visual memory, motor speed, anxiety and depression.
RESULTS: Significantly more patients with CAS showed cognitive impairments (executive functions, word production, verbal and visual memory, motor speed) and anxiety than expected in a normative sample. Bilateral and symptomatic stenosis was associated with slower processing speed. Cognitive performance and anxiety level were not influenced by the side and the degree of stenosis or the presence of collaterals. Factors associated with less co-gnitive impairment included higher education level, female gender, ambidexterity and treated hypercholesterolemia.
CONCLUSIONS: Cognitive impairment and increased level of anxiety are frequent in patients with carotid stenosis. The lack of a correlation between cognitive functioning and degree of stenosis or the presence of collaterals, challenges the view that CAS per se leads to cognitive impairment
GRAVITY: getting to the event horizon of Sgr A*
We present the second-generation VLTI instrument GRAVITY, which currently is
in the preliminary design phase. GRAVITY is specifically designed to observe
highly relativistic motions of matter close to the event horizon of Sgr A*, the
massive black hole at center of the Milky Way. We have identified the key
design features needed to achieve this goal and present the resulting
instrument concept. It includes an integrated optics, 4-telescope, dual feed
beam combiner operated in a cryogenic vessel; near infrared wavefront sensing
adaptive optics; fringe tracking on secondary sources within the field of view
of the VLTI and a novel metrology concept. Simulations show that the planned
design matches the scientific needs; in particular that 10 microarcsecond
astrometry is feasible for a source with a magnitude of K=15 like Sgr A*, given
the availability of suitable phase reference sources.Comment: 13 pages, 11 figures, to appear in the conference proceedings of SPIE
Astronomical Instrumentation, 23-28 June 2008, Marseille, Franc
Efficient Passive ICS Device Discovery and Identification by MAC Address Correlation
Owing to a growing number of attacks, the assessment of Industrial Control
Systems (ICSs) has gained in importance. An integral part of an assessment is
the creation of a detailed inventory of all connected devices, enabling
vulnerability evaluations. For this purpose, scans of networks are crucial.
Active scanning, which generates irregular traffic, is a method to get an
overview of connected and active devices. Since such additional traffic may
lead to an unexpected behavior of devices, active scanning methods should be
avoided in critical infrastructure networks. In such cases, passive network
monitoring offers an alternative, which is often used in conjunction with
complex deep-packet inspection techniques. There are very few publications on
lightweight passive scanning methodologies for industrial networks. In this
paper, we propose a lightweight passive network monitoring technique using an
efficient Media Access Control (MAC) address-based identification of industrial
devices. Based on an incomplete set of known MAC address to device
associations, the presented method can guess correct device and vendor
information. Proving the feasibility of the method, an implementation is also
introduced and evaluated regarding its efficiency. The feasibility of
predicting a specific device/vendor combination is demonstrated by having
similar devices in the database. In our ICS testbed, we reached a host
discovery rate of 100% at an identification rate of more than 66%,
outperforming the results of existing tools.Comment: http://dx.doi.org/10.14236/ewic/ICS2018.
The Fringe Detection Laser Metrology for the GRAVITY Interferometer at the VLTI
Interferometric measurements of optical path length differences of stars over
large baselines can deliver extremely accurate astrometric data. The
interferometer GRAVITY will simultaneously measure two objects in the field of
view of the Very Large Telescope Interferometer (VLTI) of the European Southern
Observatory (ESO) and determine their angular separation to a precision of 10
micro arcseconds in only 5 minutes. To perform the astrometric measurement with
such a high accuracy, the differential path length through the VLTI and the
instrument has to be measured (and tracked since Earth's rotation will
permanently change it) by a laser metrology to an even higher level of accuracy
(corresponding to 1 nm in 3 minutes). Usually, heterodyne differential path
techniques are used for nanometer precision measurements, but with these
methods it is difficult to track the full beam size and to follow the light
path up to the primary mirror of the telescope. Here, we present the
preliminary design of a differential path metrology system, developed within
the GRAVITY project. It measures the instrumental differential path over the
full pupil size and up to the entrance pupil location. The differential phase
is measured by detecting the laser fringe pattern both on the telescopes'
secondary mirrors as well as after reflection at the primary mirror. Based on
our proposed design we evaluate the phase measurement accuracy based on a full
budget of possible statistical and systematic errors. We show that this
metrology design fulfills the high precision requirement of GRAVITY.Comment: Proc. SPIE in pres
- …