110,079 research outputs found
A very wide frequency band pulsed/IF radar system
A pulsed/IF radar for compact range radar cross section measurements has been developed which converts RF returns to a fixed IF, so that amplification and grating may be performed at one frequency. This permits the use of components which have optimal performance at this frequency which results in a corresponding improvement in performance. Sensitivity and dynamic range are calculated for this system and compared with our old radar, and the effect of pulse width on clutter level is also studied. Sensitivity and accuracy tests are included to verify the performance of the radar
High-temperature, long-life thyratron
Thallium and xenon filled thyratron was developed that operates at tube envelope temperatures up to 750 C. This tube performs at peak voltage ratings of 2000 V forward and reverse and at an average current rating of 15 A for up to 11,000 hours
Development of high-temperature, gas-filled, ceramic rectifiers, thyratrons, and voltage-reference tubes Final report, Dec. 15, 1964 - Jan. 26, 1966
Development of high temperature gas filled ceramic rectifiers, thyratrons, and voltage-regulator tube
Determination of load sequence effects on the degradation and failure of composite materials
A theoretical model was established to predict the fatigue behavior of composite materials, with emphasis placed on predictions of the degradation of residual strength and residual stiffness during fatigue cycling. The model parameters were evaluated from three test series including static strength fatigue life and residual strength tests. The tests were applied to two graphite/epoxy laminates. Load sequence effects were emphasized for both laminates and the predicted results agreed quite well with subsequent verification tests. Dynamic as well as static stiffness reduction data were collected by use of a PDP11-03 computer, which performed quite satisfactorily and permitted the recording of a substantial amount of dynamic stiffness reduction data
Statistical characterization of the fatigue behavior of composite lamina
A theoretical model was developed to predict statistically the effects of constant and variable amplitude fatigue loadings on the residual strength and fatigue life of composite lamina. The parameters in the model were established from the results of a series of static tensile tests and a fatigue scan and a number of verification tests were performed. Abstracts for two other papers on the effect of load sequence on the statistical fatigue of composites are also presented
Design and development of a self-healing fuse
Mercury-filled self-healing fuses for protecting solid state circuits from faults - design and developmen
Recommended from our members
Portable Perimetry Using Eye-Tracking on a Tablet Computer—A Feasibility Assessment
Purpose: Visual field (VF) examination by standard automated perimetry (SAP) is an important method of clinical assessment. However, the complexity of the test, and its use of bulky, expensive equipment makes it impractical for case-finding. We propose and evaluate a new approach to paracentral VF assessment that combines an inexpensive eye-tracker with a portable tablet computer (“Eyecatcher”).
Methods: Twenty-four eyes from 12 glaucoma patients, and 12 eyes from six age-similar controls were examined. Participants were tested monocularly (once per eye), with both the novel Eyecatcher test and traditional SAP (HFA SITA standard 24-2). For Eyecatcher, the participant's task was to simply to look at a sequence of fixed-luminance dots, presented relative to the current point of fixation. Start and end fixations were used to determine locations where stimuli were seen/unseen, and to build a continuous map of sensitivity loss across a VF of approximately 20°.
Results: Eyecatcher was able to clearly separate patients from controls, and the results were consistent with those from traditional SAP. In particular, mean Eyecatcher scores were strongly correlated with mean deviation scores (r2 = 0.64, P < 0.001), and there was good concordance between corresponding VF locations (∼84%). Participants reported that Eyecatcher was more enjoyable, easier to perform, and less tiring than SAP (all P < 0.001).
Conclusions: Portable perimetry using an inexpensive eye-tracker and a tablet computer is feasible, although possible means of improvement are suggested.
Translational Relevance: Such a test could have significant utility as a case finding device
Self-healing fuse
Fast-acting current limiting device provides current overload protection for vulnerable circuit elements and then re-establishes conduction path within milliseconds. Fuse can also perform as fast-acting switch to clear transient circuit overloads. Fuse takes advantage of large increase in electrical resistivity that occurs when liquid metal vaporizes
Implications of an r-mode in XTE J1751-305: Mass, radius and spin evolution
Recently Strohmayer and Mahmoodifar presented evidence for a coherent
oscillation in the X-ray light curve of the accreting millisecond pulsar XTE
J1751-305, using data taken by RXTE during the 2002 outburst of this source.
They noted that a possible explanation includes the excitation of a non-radial
oscillation mode of the neutron star, either in the form of a g-mode or an
r-mode. The r-mode interpretation has connections with proposed spin-evolution
scenarios for systems such as XTE J1751-305. Here we examine in detail this
interesting possible interpretation. Using the ratio of the observed
oscillation frequency to the star's spin frequency, we derive an approximate
neutron star mass-radius relation which yields reasonable values for the mass
over the range of expected stellar radius (as constrained by observations of
radius-expansion burst sources). However, we argue that the large mode
amplitude suggested by the Strohmayer and Mahmoodifar analysis would inevitably
lead to a large spin-down of the star, inconsistent with its observed spin
evolution, regardless of whether the r-mode itself is in a stable or unstable
regime. We therefore conclude that the r-mode interpretation of the observed
oscillation is not consistent with our current understanding of neutron star
dynamics and must be considered unlikely. Finally we note that, subject to the
availability of a sufficiently accurate timing model, a direct
gravitational-wave search may be able to confirm or reject an r-mode
interpretation unambiguously, should such an event, with a similar inferred
mode amplitude, recur during the Advanced detector era.Comment: 8 pages, 3 figures; submitted to MNRA
- …