5,194 research outputs found

    Chemiluminescent Tags for Tracking Insect Movement in Darkness: Application to Moth Photo-Orientation

    Get PDF
    The flight tracks of Manduca sexta (Lepidoptera: Sphingidae) flying toward a 5 watt incandescent light bulb were recorded under low light conditions with the aid of a camera-mounted photomultiplier and a glowing marker technique. Small felt pads bearing a chemiluminescent (glowi ma­erial, Cyalume®, were affixed to the abdomens of free-flying moths. insects orienting to a dim incandescent bulb were easily visible to the naked eye and were clearly captured on videotape. On their initial approach to the light source, M. sexta were found to orient at a mean angle of -0.220 ± 2.70 (mean ± SEM). The speed of the initial approach flight (OA ± 0.03 m/s) was significantly faster than the speed immediately after passing the light (0.29 ± 0.02 m/s; t =6.4, PM. sexta initially fly approximately at a light source and only after passing it, do they engage in circular flight around the source. M. sexta flight to lights does not entirely match any paths predicted by several light orientation mechanisms, including the commonly invoked light compass theory

    Electrical switching in a magnetically intercalated transition metal dichalcogenide.

    Get PDF
    Advances in controlling the correlated behaviour of transition metal dichalcogenides have opened a new frontier of many-body physics in two dimensions. A field where these materials have yet to make a deep impact is antiferromagnetic spintronics-a relatively new research direction promising technologies with fast switching times, insensitivity to magnetic perturbations and reduced cross-talk1-3. Here, we present measurements on the intercalated transition metal dichalcogenide Fe1/3NbS2 that exhibits antiferromagnetic ordering below 42 K (refs. 4,5). We find that remarkably low current densities of the order of 104 A cm-2 can reorient the magnetic order, which can be detected through changes in the sample resistance, demonstrating its use as an electronically accessible antiferromagnetic switch. Fe1/3NbS2 is part of a larger family of magnetically intercalated transition metal dichalcogenides, some of which may exhibit switching at room temperature, forming a platform from which to build tuneable antiferromagnetic spintronic devices6,7

    Retro-biosynthetic screening of a modular pathway design achieves selective route for microbial synthesis of 4-methyl-pentanol

    Get PDF
    Increasingly complex metabolic pathways have been engineered by modifying natural pathways and establishing de novo pathways with enzymes from a variety of organisms. Here we apply retro-biosynthetic screening to a modular pathway design to identify a redox neutral, theoretically high yielding route to a branched C6 alcohol. Enzymes capable of converting natural E. coli metabolites into 4-methyl-pentanol (4MP) via coenzyme A (CoA)-dependent chemistry were taken from nine different organisms to form a ten-step de novo pathway. Selectivity for 4MP is enhanced through the use of key enzymes acting on acyl-CoA intermediates, a carboxylic acid reductase from Nocardia iowensis and an alcohol dehydrogenase from Leifsonia sp. strain S749. One implementation of the full pathway from glucose demonstrates selective carbon chain extension and acid reduction with 4MP constituting 81% (90±7 mg l⁻¹) of the observed alcohol products. The highest observed 4MP titre is 192±23 mg l⁻¹. These results demonstrate the ability of modular pathway screening to facilitate de novo pathway engineering.United States. Army Research Office (W911NF-09-0001

    Bostonia. Volume 4

    Full text link
    Founded in 1900, Bostonia magazine is Boston University's main alumni publication, which covers alumni and student life, as well as university activities, events, and programs

    Yang-Mills gravity in biconformal space

    Get PDF
    We write a gravity theory with Yang-Mills type action using the biconformal gauging of the conformal group. We show that the resulting biconformal Yang-Mills gravity theories describe 4-dim, scale-invariant general relativity in the case of slowly changing fields. In addition, we systematically extend arbitrary 4-dim Yang-Mills theories to biconformal space, providing a new arena for studying flat space Yang-Mills theories. By applying the biconformal extension to a 4-dim pure Yang-Mills theory with conformal symmetry, we establish a 1-1, onto mapping between a set of gravitational gauge theories and 4-dim, flat space gauge theories.Comment: 27 pages; paper emphasis shifted to focus on gravity; references adde

    Centerscope

    Full text link
    Centerscope, formerly Scope, was published by the Boston University Medical Center "to communicate the concern of the Medical Center for the development and maintenance of improved health care in contemporary society.

    Demonstration of a switchable damping system to allow low-noise operation of high-Q low-mass suspension systems

    Get PDF
    Low mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilising multiple pendulum stages with vertical blade springs and materials with high quality factors provides attenuation of seismic and thermal noise, however damping of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementation. Viscous damping such as eddy-current damping can be employed but introduces displacement noise from force noise due to thermal fluctuations in the damping system. In this paper we demonstrate a passive damping system with adjustable damping strength as a solution for this problem that can be used for low mass suspension systems without adding additional displacement noise in science mode. We show a reduction of the damping factor by a factor of 8 on a test suspension and provide a general optimisation for this system.Comment: 5 pages, 5 figure

    The SKA Particle Array Prototype: The First Particle Detector at the Murchison Radio-astronomy Observatory

    Full text link
    We report on the design, deployment, and first results from a scintillation detector deployed at the Murchison Radio-astronomy Observatory (MRO). The detector is a prototype for a larger array -- the Square Kilometre Array Particle Array (SKAPA) -- planned to allow the radio-detection of cosmic rays with the Murchison Widefield Array and the low-frequency component of the Square Kilometre Array. The prototype design has been driven by stringent limits on radio emissions at the MRO, and to ensure survivability in a desert environment. Using data taken from Nov.\ 2018 to Feb.\ 2019, we characterize the detector response while accounting for the effects of temperature fluctuations, and calibrate the sensitivity of the prototype detector to through-going muons. This verifies the feasibility of cosmic ray detection at the MRO. We then estimate the required parameters of a planned array of eight such detectors to be used to trigger radio observations by the Murchison Widefield Array.Comment: 17 pages, 14 figures, 3 table

    Development and clinical performance of high throughput loop-mediated isothermal amplification for detection of malaria.

    Get PDF
    BACKGROUND: Accurate and efficient detection of sub-microscopic malaria infections is crucial for enabling rapid treatment and interruption of transmission. Commercially available malaria LAMP kits have excellent diagnostic performance, though throughput is limited by the need to prepare samples individually. Here, we evaluate the clinical performance of a newly developed high throughput (HTP) sample processing system for use in conjunction with the Eiken malaria LAMP kit. METHODS: The HTP system utilised dried blood spots (DBS) and liquid whole blood (WB), with parallel sample processing of 94 samples per run. The system was evaluated using 699 samples of known infection status pre-determined by gold standard nested PCR. RESULTS: The sensitivity and specificity of WB-HTP-LAMP was 98.6% (95% CI, 95.7-100), and 99.7% (95% CI, 99.2-100); sensitivity of DBS-HTP-LAMP was 97.1% (95% CI, 93.1-100), and specificity 100% against PCR. At parasite densities greater or equal to 2 parasites/μL, WB and DBS HTP-LAMP showed 100% sensitivity and specificity against PCR. At densities less than 2 p/μL, WB-HTP-LAMP sensitivity was 88.9% (95% CI, 77.1-100) and specificity was 99.7% (95% CI, 99.2-100); sensitivity and specificity of DBS-HTP-LAMP was 77.8% (95% CI, 54.3-99.5) and 100% respectively. CONCLUSIONS: The HTP-LAMP system is a highly sensitive diagnostic test, with the potential to allow large scale population screening in malaria elimination campaigns
    corecore