435 research outputs found
Design and construction of new central and forward muon counters for CDF II
New scintillation counters have been designed and constructed for the CDF
upgrade in order to complete the muon coverage of the central CDF detector, and
to extend this coverage to larger pseudorapidity. A novel light collection
technique using wavelength shifting fibers, together with high quality
polystyrene-based scintillator resulted in compact counters with good and
stable light collection efficiency over lengths extending up to 320 cm. Their
design and construction is described and results of their initial performance
are reported.Comment: 20 pages, 15 figure
Microchannel avalanche photodiode with wide linearity range
Design and physical operation principles of new microchannel avalanche
photodiode (MC APD) with gain up to 10^5 and linearity range improved an order
of magnitude compared to known similar devices. A distinctive feature of the
new device is a directly biased p-n junction under each pixel which plays role
of an individual quenching resistor. This allows increasing pixel density up to
40000 per mm^2 and making entire device area sensitive.Comment: Submitted to Journal of Technical Physic
Search for the Supersymmetric Partner of the Top-Quark in Collisions at
We report on a search for the supersymmetric partner of the top quark (stop)
produced in events using of
collisions at recorded with the Collider Detector at
Fermilab. In the case of a light stop squark, the decay of the top quark into
stop plus the lightest supersymmetric particle (LSP) could have a significant
branching ratio. The observed events are consistent with Standard Model production and decay. Hence, we set limits on the branching ratio of
the top quark decaying into stop plus LSP, excluding branching ratios above 45%
for a LSP mass up to 40 {\rm GeV/c}.Comment: 11 pages, 4 figure
Measurement of the B0 anti-B0 oscillation frequency using l- D*+ pairs and lepton flavor tags
The oscillation frequency Delta-md of B0 anti-B0 mixing is measured using the
partially reconstructed semileptonic decay anti-B0 -> l- nubar D*+ X. The data
sample was collected with the CDF detector at the Fermilab Tevatron collider
during 1992 - 1995 by triggering on the existence of two lepton candidates in
an event, and corresponds to about 110 pb-1 of pbar p collisions at sqrt(s) =
1.8 TeV. We estimate the proper decay time of the anti-B0 meson from the
measured decay length and reconstructed momentum of the l- D*+ system. The
charge of the lepton in the final state identifies the flavor of the anti-B0
meson at its decay. The second lepton in the event is used to infer the flavor
of the anti-B0 meson at production. We measure the oscillation frequency to be
Delta-md = 0.516 +/- 0.099 +0.029 -0.035 ps-1, where the first uncertainty is
statistical and the second is systematic.Comment: 30 pages, 7 figures. Submitted to Physical Review
Response of the ATLAS tile calorimeter prototype to muons
A study of high energy muons traversing the ATLAS hadron Tile calorimeter in the barrel region in the energy range between 10 and 300~GeV is presented. Both test beam experimental data and Monte Carlo simulations are given and show good agreement. The Tile calorimeter capability of detecting isolated muons over the above energy range is demonstrated. A signal to background ratio of about 10 is expected for the nominal LHC luminosity (). The photoelectron statistics effect in the muon shape response is shown. The e/mip ratio is found to be ; the e/ ratio is in the range 0.91 - 0.97. The energy loss of a muon in the calorimeter, dominated by the energy lost in the absorber, can be correlated to the energy loss in the active material. This correlation allows one to correct on an event by event basis the muon energy loss in the calorimeter and therefore reduce the low energy tails in the muon momentum distribution
Results from a combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter
The first combined test of an electromagnetic liquid argon accordion calorimeter and a hadronic scintillating-tile calorimeter was carried out at the CERN SPS. These devices are prototypes of the barrel calorimeter of the future ATLAS experiment at the LHC. The energy resolution of pions in the energy range from 20 to 300~GeV at an incident angle of about 11 is well-described by the expression \sigma/E = ((46.5 \pm 6.0)\%/\sqrt{E} +(1.2 \pm 0.3)\%) \oplus (3.2 \pm 0.4)~\mbox{GeV}/E. Shower profiles, shower leakage, and the angular resolution of hadronic showers were also studied
First Measurement of the Ratio B ( t → Wb ) / B ( t → Wq ) and Associated Limit on the Cabibbo-Kobayashi-Maskawa Element | V tb |
Evaluation of Fermi Read-out of the ATLAS Tilecal Prototype
Prototypes of the \fermi{} system have been used to read out a prototype of the \atlas{} hadron calorimeter in a beam test at the CERN SPS. The \fermi{} read-out system, using a compressor and a 40 MHz sampling ADC, is compared to a standard charge integrating read-out by measuring the energy resolution of the calorimeter separately with the two systems on the same events. Signal processing techniques have been designed to optimize the treatment of \fermi{} data. The resulting energy resolution is better than the one obtained with the standard read-out
- …