41,073 research outputs found
Solar cell angular position transducer
An angular position transducer utilizing photocells and a light source is disclosed. The device uses a fully rotatable baffle which is connected via an actuator shaft to the body whose rotational displacement is to be measured. The baffle blocks the light path between the light source and the photocells so that a constant semicircular beam of light reaches the photocells. The current produced by the photocells is fed through a resistor, a differential amplifier measures the voltage drop across the resistor which indicates the angular position of the actuator shaft and hence of the object
Extreme paths in oriented 2D Percolation
A useful result about leftmost and rightmost paths in two dimensional bond
percolation is proved. This result was introduced without proof in \cite{G} in
the context of the contact process in continuous time. As discussed here, it
also holds for several related models, including the discrete time contact
process and two dimensional site percolation. Among the consequences are a
natural monotonicity in the probability of percolation between different sites
and a somewhat counter-intuitive correlation inequality
Recommended from our members
Rurality, productivity and skills in the East Midlands: final report
This report sets out the findings of research into the relationship between rurality, skills and productivity in the East Midlands. The report has been prepared by the Enterprise Research and Development Unit (ERDU) at the University of Lincoln on behalf of the East Midlands Development Agency (emda)
ITOS VHRR on-board data compression study
Data compression methods for ITOS VHRR data were studied for a tape recorder record-and playback application. A playback period of 9 minutes was assumed with a nominal 18 minute record period for a 2-to-1 compression ratio. Both analog and digital methods were considered with the conclusion that digital methods should be used. Two system designs were prepared. One is a PCM system and the other is an entropy-coded predictive-quantization, sometimes called entropy-coded DPCM or just DPCM, system. Both systems use data management principles to transmit only the necessary data. Both systems use a medium capacity standard tape recorder from specifications provided by the technical officer. The 10 to the 9th power bit capacity of the recorder is the basic limitation on the compression ratio. Both systems achieve the minimum desired 2 to 1 compression ratio. A slower playback rate can be used with the DPCM system due to a higher compression factor for better link performance at a given CNR in terms of bandwidth utilization and error rate. The report is divided into two parts. The first part summarizes the theoretical conclusions of the second part and presents the system diagrams. The second part is a detailed analysis based upon an empirically derived random process model arrived at from specifications and measured data provided by the technical officer
Preliminary design study - Oxidizer tank helium pressure regulator, Flox-Atlas, airborne Final report
Oxidizer tank helium pressure regulator compatible with fluorine-liquid oxyge
A field-deployable digital acoustic measurement system
A field deployable digital acoustic measurement system was developed to support acoustic research programs at the Langley Research Center. The system digitizes the acoustic inputs at the microphone, which can be located up to 1000 feet from the van which houses the acquisition, storage, and analysis equipment. Digitized data from up to 12 microphones is recorded on high density 8mm tape and is analyzed post-test by a microcomputer system. Synchronous and nonsynchronous sampling is available with maximum sample rates of 12,500 and 40,000 samples per second respectively. The high density tape storage system is capable of storing 5 gigabytes of data at transfer rates up to 1 megabyte per second. System overall dynamic range exceeds 83 dB
- …