51 research outputs found

    Fiber-optic breath sensors: A comparison study

    Get PDF
    The paper presents a comparative study of three fiber optic sensors based on the fiber Bragg grating (FBG). The basic monitored parameter is the respiratory rate of the human body. Fiber-optic sensors are immune to electromagnetic interference (EMI). This fact singles them out as ideal for use in magnetic resonance environments (typically in MRI -magnetic resonance imaging) as a prediction of hyperventilation states in patients. These patient conditions arise as a result of the closed tunnel environment in MR scanners. The results (10 volunteers with written consent) were compared with the results using the conventional respiratory belt (RB) in a laboratory environment and processed using the objective Bland-Altman (B-A) method.Web of Science40635

    Methods of power line interference elimination in EMG signals

    Get PDF
    Electromyogram (EMG) recordings are often corrupted by the wide range of artifacts, which one of them is power line interference (PLI). The study focuses on some of the well-known signal processing approaches used to eliminate or attenuate PLI from EMG signal. The results are compared using signal-to-noise ratio (SNR), correlation coefficients and Bland-Altman analysis for each tested method: notch filter, adaptive noise canceller (ANC) and wavelet transform (WT). Thus, the power of the remaining noise and shape of the output signal are analysed. The results show that the ANC method gives the best output SNR and lowest shape distortion compared to the other methods.Web of Science40706

    Design of a new method for detection of occupancy in the smart home using an FBG sensor

    Get PDF
    This article introduces a new way of using a fibre Bragg grating (FBG) sensor for detecting the presence and number of occupants in the monitored space in a smart home (SH). CO2 sensors are used to determine the CO2 concentration of the monitored rooms in an SH. CO2 sensors can also be used for occupancy recognition of the monitored spaces in SH. To determine the presence of occupants in the monitored rooms of the SH, the newly devised method of CO2 prediction, by means of an artificial neural network (ANN) with a scaled conjugate gradient (SCG) algorithm using measurements of typical operational technical quantities (indoor temperature, relative humidity indoor and CO2 concentration in the SH) is used. The goal of the experiments is to verify the possibility of using the FBG sensor in order to unambiguously detect the number of occupants in the selected room (R104) and, at the same time, to harness the newly proposed method of CO2 prediction with ANN SCG for recognition of the SH occupancy status and the SH spatial location (rooms R104, R203, and R204) of an occupant. The designed experiments will verify the possibility of using a minimum number of sensors for measuring the non-electric quantities of indoor temperature and indoor relative humidity and the possibility of monitoring the presence of occupants in the SH using CO2 prediction by means of the ANN SCG method with ANN learning for the data obtained from only one room (R203). The prediction accuracy exceeded 90% in certain experiments. The uniqueness and innovativeness of the described solution lie in the integrated multidisciplinary application of technological procedures (the BACnet technology control SH, FBG sensors) and mathematical methods (ANN prediction with SCG algorithm, the adaptive filtration with an LMS algorithm) employed for the recognition of number persons and occupancy recognition of selected monitored rooms of SH.Web of Science202art. no. 39

    Modeling of fiber optic sensors with Bragg gratings

    Get PDF
    Optovláknové Braggovské mřížky představují alternativní přístup pro senzorické aplikace a postupně nahrazují standardní typy senzorů. Jedná se o bodové senzory, které lze velmi snadno multiplexovat. Tato práce se zabývá modelováním optovláknových senzorů s Braggovskými mřížkami využívající vlnový multiplex. Cílem práce je návrh matematického modelu, který popisuje pomocí obecných rovnic senzorickou větev a parametry jednotlivých Braggovských mřížek a slouží pro návrh reálné senzorické větve s Braggovskými senzory. Tento návrh umožňuje efektivně využít omezenou šířku spektra zdroje záření pro dosažení co největšího počtu Braggovských senzorů v senzorické větvi.Fiber optic Bragg gratings represent an alternative approach for sensory applications and gradually replace the standard types of sensors. These single point sensors can be easily multiplexed. The aim of this work is a proposal of the mathematical model describing the sensory network, individual FBGs, and their parameters. The main contribution of the mathematical model is an effective design of the sensory network. This effective design is very important due to the limited spectral width of the light source.440 - Katedra telekomunikační technikyvyhově

    Analysis of the applicability of singlemode optical fibers for measurement of deformation with distributed systems BOTDR

    Get PDF
    Distributed optical fiber sensors allow monitoring physical effects across the whole cable. The paper presents results obtained from the performed tests and shows that single mode fibers can provide analyses of the deformation changes, when distributed optical systems BOTDR used. We used standard optical fiber G.652.D with primary and secondary protected layers and specialized cable SMC-V4 designed for this purpose. The aim was to compare the deformation sensitivity and determine which fiber types are the best to use. We deformed the fiber in the longitudinal and transverse directions and mechanically stressed in orthogonal directions to find how to localize optical fibers. They could be deployed in real use. For achieving optimal results of mechanical changes and acting forces, sensor fibers have to be located carefully

    Encapsulation of FBG sensor into the PDMS and its effect on spectral and temperature characteristics

    Get PDF
    Fiber Bragg Grating (FBG) is the most distributed type of fiber-optic sensors. FBGs are primarily sensitive to the effects of temperature and deformation. By employing different transformation techniques, it is possible to use FBG to monitor any physical quantity. To use them as parts of sensor applications, it is essential to encapsulate FBGs to achieve their maximum protection against external effects and damage. Another reason to encapsulate is increasing of sensitivity to the measured quantity. Polydimethylsiloxane (PDMS) encapsulation appears to be an interesting alternative due to convenient temperature and flexibility of the elastomer. This article describes an experimental proposal of FBG PDMS encapsulation process, also providing an analysis of the FBG spectral characteristics and temperature sensitivity, both influenced by high temperature and the process of polydimethylsiloxane curing itself. As for the PDMS type, Sylgard 184 was employed. Encapsulation consisted of several steps: allocation of FBG to PDMS in its liquid state, curing PDMS at the temperature of 80°C ± 5 %, and a 50-minute relaxation necessary to stabilize a Bragg wavelength. A broadband light source and an optical spectrum analyzer were both used to monitor the parameters during the processes of curing and relaxation. Presented results imply that such a method of encapsulation does not have any influence on the structure or functionality of the FBG. At the same time, a fourfold increase of temperature sensitivity was monitored when compared to a bare FBG

    Vital sign monitoring and cardiac triggering at 1.5 Tesla: A practical solution by an MR-ballistocardiography fiber-optic sensor

    Get PDF
    This article presents a solution for continuous monitoring of both respiratory rate (RR) and heart rate (HR) inside Magnetic Resonance Imaging (MRI) environments by a novel ballistocardiography (BCG) fiber-optic sensor. We designed and created a sensor based on the Fiber Bragg Grating (FBG) probe encapsulated inside fiberglass (fiberglass is a composite material made up of glass fiber, fabric, and cured synthetic resin). Due to this, the encapsulation sensor is characterized by very small dimensions (30 x 10 x 0.8 mm) and low weight (2 g). We present original results of real MRI measurements (conventionally most used 1.5 T MR scanner) involving ten volunteers (six men and four women) by performing conventional electrocardiography (ECG) to measure the HR and using a Pneumatic Respiratory Transducer (PRT) for RR monitoring. The acquired sensor data were compared against real measurements using the objective Bland-Altman method, and the functionality of the sensor was validated (95.36% of the sensed values were within the +/- 1.96 SD range for the RR determination and 95.13% of the values were within the +/- 1.96 SD range for the HR determination) by this means. The accuracy of this sensor was further characterized by a relative error below 5% (4.64% for RR and 4.87% for HR measurements). The tests carried out in an MRI environment demonstrated that the presence of the FBG sensor in the MRI scanner does not affect the quality of this imaging modality. The results also confirmed the possibility of using the sensor for cardiac triggering at 1.5 T (for synchronization and gating of cardiovascular magnetic resonance) and for cardiac triggering when a Diffusion Weighted Imaging (DWI) is used.Web of Science193art. no. 47

    Multiple transcoding impact on speech quality in ideal network conditions

    Get PDF
    This paper deals with the impact of transcoding on the speech quality. We have focused mainly on the transcoding between codecs without the negative influence of the network parameters such as packet loss and delay. It has ensured objective and repeatable results from our measurement. The measurement was performed on the Transcoding Measuring System developed especially for this purpose. The system is based on the open source projects and is useful as a design tool for VoIP system administrators. The paper compares the most used codecs from the transcoding perspective. The multiple transcoding between G711, GSM and G729 codecs were performed and the speech quality of these calls was evaluated. The speech quality was measured by Perceptual Evaluation of Speech Quality method, which provides results in Mean Opinion Score used to describe the speech quality on a scale from 1 to 5. The obtained results indicate periodical speech quality degradation on every transcoding between two codecs

    Non-destructive fiber-optic sensor system for the measurement of speed in road traffic

    Get PDF
    Fiber-optic sensors offer an attractive option to existing sensors for the measurement of the vehicle speed in road traffic. This article describes the measuring scheme of two interferometric sensor units including input-output components for the measurement of the vehicle speed. The interferometric sensors operate on a principle of Mach-Zehnder interferometer. The sensors are constructed to detect a vibration caused by vehicles moving on roads. The sensor system processes the vibrational response, and the vehicle speed is calculated in a time domain. DFB laser was used with a wavelength of 1550 nm and output power of 1--5~mW. The solution provides very high sensitivity. The performance of the proposed system was verified by a series of experimental measurements of the speed. The vehicle speed was monitored by GPS. The highest relative difference of the evaluated speed against GPS data was 7.7 %, the smallest was 1.36 %. When recalculated on kph, the absolute error ranged in the tolerance ± 3 kph, which denotes segmental measuring systems in CZE

    Speech quality measurement of GSM infrastructure built on USRP N210 and OpenBTS project

    Get PDF
    The paper deals with the methodology for speech quality measuring in GSM networks using Perceptual Evaluation of Speech Quality (PESQ). The paper brings results of practical measurement of own GSM network build on the Universal Software Radio Peripheral (USRP N210) hardware and OpenBTS software. This OpenBTS station was installed in open terrain, and the speech quality was measured from different distances from the transmitter. The limit parameters of OpenBTS station with USRP N210 were obtained