1,323 research outputs found
Application of imaging to the atmospheric Cherenkov technique
Turver and Weekes proposed using a system of phototubes in the focal plane of a large reflector to give an air Cherenkov camera for gamma ray astronomy. Preliminary results with a 19 element camera have been reported previously. In 1983 the camera was increased to 37 pixels; it has now been routinely operated for two years. A brief physical description of the camera, its mode of operation, and the data reduction procedures are presented. The Monte Carlo simultations on which these are based on also reviewed
Locating very high energy gamma ray sources with arc minute accuracy
The angular accuracy of gamma-ray detectors is intrinsically limited by the physical processes involved in photon detection. Although a number of point-like sources were detected by the COS-B satellite, only two were unambiguously identified by time signature with counterparts at longer wavelengths. By taking advantage of the extended longitudinal structure of Very High Energy gamma-ray showers, measurements in the TeV energy range can pinpoint source coordinates to arc minute accuracy. This was demonstrated using Cerenkov air shower imaging techniques. With two telescopes in coincidence, the individual event circular probable error will be 0.13 deg. The half-cone angle of the field of view is effectively 1 deg
Status of the Whipple Observatory Cerenkov air shower imaging telescope array
Recently the power of the Cerenkov imaging technique in Very High Energy gamma-ray astronomy was demonstrated by the detection of the Crab nebula at high statistical significance. In order to further develop this technique to allow the detection of weaker or more distant sources a second 10 m class reflector was constructed about 120 m from the original instrument. The addition of the second reflector will allow both a reduction in the energy threshold and an improvement in the rejection of the hadronic background. The design and construction of the second reflector, Gamma Ray Astrophysics New Imaging TElescope (GRANITE) is described
Observations of TeV gamma rays from Markarian 501 at large zenith angles
TeV gamma rays from the blazar Markarian 501 have been detected with the
University of Durham Mark 6 atmospheric Cerenkov telescope using the imaging
technique at large zenith angles. Observations were made at zenith angles in
the range 70 - 73 deg during 1997 July and August when Markarian 501 was
undergoing a prolonged and strong flare.Comment: 7 pages, 2 figures, accepted for publication in J. Phys. G.: Nucl.
Part. Phy
Search for gamma-rays from M31 and other extragalactic objects
Although the existence of fluxes of gamma-rays of energies 10 to the 12th power eV is now established for galactic sources, the detection of such gamma-rays from extragalactic sources has yet to be independently confirmed in any case. The detection and confirmation of such energetic photons is of great astrophysical importance in the study of production mechanisms for cosmic rays, and other high energy processes in extragalactic objects. Observations of m31 are discussed. It is reported as a 10 to the 12th power eV gamma-ray source. Flux limits on a number of other extragalactic objects chosen for study are given
Search for gamma-rays above 400 GeV from Geminga
Observations of Geminga made at the Whipple Observatory using the atmospheric Cherenkov technique during the moonless periods of November 1983 to February 1984 and November 1984 till February 1985 were examined for evidence for the emission of gamma rays with energy in excess of approx 400 GeV. Evidence of either a steady flux or a flux pulsed with a period near 60 seconds were studied. In neither case was any significant effect observed, enabling the establishment 3 of sigma upper limits of 5.5 x 10 to the -11th power photons/sq cm/s and 2.0 x 10 to the -11th power photons/sq cm/s for the steady and pulsed emission respectively. The limit to the pulsed flux is approximately a factor of six below that predicted
Variability in the high energy gamma ray emission from Cyg X-3 over a two-year period (1983 - 1984) at E 4 x 10(11) eV
Cygnus X-3 is observed to emit gamma rays with energies in excess of 4 x 10 to the 11th power eV during two out of 9 observational categories over an 18 month time span. The emissions are observed at the 0.6 phase of the characteristic 4.8 hr light curve for this binary system. We estimate a peak flux at phase 0.6 of 5 x 10 to the minus 10th power photons cm-2s-1 at a software threshold of 8 x 10 to the 11th power eV for Oct/Nov 1983. A flux for the June 84 effect cannot be reliably calculated at present due to lack of Monte Carlo simulations for the energy range and spectral region. For the other 7 observational categories the observations are consistent with zero source emission. The light curve would appear to be variable on a time scale of a couple of weeks at these categories. Selection of compact images in accordance with Monte Carlo simulations combined with empirical optimization techniques have led to an enriched gamma ray light curve for the Oct/Nov 1983 data. Selection on the basis of shower orientation, however, has not led to any notable enhancement of the gamma ray content. Individual Cherenko images can be reliably sorted on an event by event basis into either proton-induced or photon-induced showers
Observations of the Crab Nebula at energies 4.10(11)
Since the development of gamma-ray astronomical telescopes, the Crab Nebula has been a prime target for observations. From 100 to 1000 MeV, the pulsar PSR0531 is the dominant source with a light-curve similar to that seen at lower energies; there is also some evidence for longterm amplitude variations but none for emission from the Nebula itself. In the very high energy gamma-ray region there have been reported detections of pulsed emission with longterm time variations from minutes to months. Recently a pulsed flux has been reported that resisted over a long time interval. The detection of a flux from the Nebula at the 3 sigma level at energies of 3x1011eV was reported; there was no evidence of periodic emissions on any time scale during the three years of observations. A new measurement of very high energy gamma rays from the Crab Nebula is reported using the imaging system on the Whipple Observatory 10m reflector
Hercules X-1: Pulsed gamma-rays detected above 150 GeV
The 1.24 second binary pulsar Her X-1, first observed in X-rays in 1971 by UHURU has now been seen as a sporadic gamma ray source from 1 TeV up to at least 500 TeV. In addition, reprocessed optical and infrared pulses are seen from the companion star HZ Herculis. Thus measurements of the Her X-1/HZ Herculis system span 15 decades in energy, rivaling both the Crab pulsar and Cygnus X-3 in this respect for a discrete galactic source
- …