    CMS Central Hadron Calorimeter

    Get PDF
    We present a description of the CMS central hadron calorimeter. We describe the production of the 1996 CMS hadron testbeam module. We show the results of the quality control tests of the testbeam module. We present some results of the 1995 CMS hadron testbeam.Comment: 7 pages, 11 Figures, corresponding author: H. Budd, [email protected]

    Research Report: Usefulness of investigating error profiles in diagnosis of naming impairments

    Get PDF
    peer-reviewedBackground: Word-retrieval difficulties are commonly experienced by people with aphasia (PwA) and also by typically ageing persons. Differentiation between true naming impairments and naming difficulties found in healthy persons may, therefore, be challenging. Aims: To investigate the extent to which the Maltese adaptation of the Boston Naming Test (BNT) can identify people with lexical retrieval difficulties and to differentiate them from people with unimpaired word finding. Methods & Procedures: Naming performance of a group of PwA was compared with the performance of a control group. Performance on theMaltese adaptation of the BNT was investigated in terms of scores, range of scores and error profiles of the two groups. Outcomes & Results: All PwA scored below the mean score of the controls, indicating that persons who scored above the mean score may be considered as unimpaired. However, a number of the controls obtained very low scores that overlapped with the scores obtained by the PwA. This indicated that scores alone cannot be used to differentiate between impaired and unimpaired people. Some types of errors were only produced by people with impaired naming, and did not appear at all in error profiles of unimpaired individuals. Conclusions & Implications: Mild–moderate anomic impairments may be missed if naming impairment is assessed and diagnosed using a cut-off score. In order to differentiate between people with impaired and unimpaired naming, it is necessary to look at error profiles, apart from the number of errors, as the presence of atypical errors may be an important indicator of naming impairments

    Constitutivism

    Get PDF
    A brief explanation and overview of constitutivism

    The twilight of the Liberal Social Contract? On the Reception of Rawlsian Political Liberalism

    Get PDF
    This chapter discusses the Rawlsian project of public reason, or public justification-based 'political' liberalism, and its reception. After a brief philosophical rather than philological reconstruction of the project, the chapter revolves around a distinction between idealist and realist responses to it. Focusing on political liberalism’s critical reception illuminates an overarching question: was Rawls’s revival of a contractualist approach to liberal legitimacy a fruitful move for liberalism and/or the social contract tradition? The last section contains a largely negative answer to that question. Nonetheless the chapter's conclusion shows that the research programme of political liberalism provided and continues to provide illuminating insights into the limitations of liberal contractualism, especially under conditions of persistent and radical diversity. The programme is, however, less receptive to challenges to do with the relative decline of the power of modern states

    Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF

    Full text link
    The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described

    Adaptation of the WHO Essential Medicines List for national antibiotic stewardship policy in England: being AWaRe.

    Get PDF
    OBJECTIVES:Appropriate use of and access to antimicrobials are key priorities of global strategies to combat antimicrobial resistance (AMR). The WHO recently classified key antibiotics into three categories (AWaRe) to improve access (Access), monitor important antibiotics (Watch) and preserve effectiveness of 'last resort' antibiotics (Reserve). This classification was assessed for antibiotic stewardship and quality improvement in English hospitals. METHODS:Using an expert elicitation exercise, antibiotics used in England but not included in the WHO AWaRe index were added to an appropriate category following a workshop consensus exercise with national experts. The methodology was tested using national antibiotic prescribing data and presented by primary and secondary care. RESULTS:In 2016, 46/108 antibiotics included within the WHO AWaRe index were routinely used in England and an additional 25 antibiotics also commonly used in England were not included in the WHO AWaRe index. WHO AWaRe-excluded and -included antibiotics were reviewed and reclassified according to the England-adapted AWaRE index with the justification by experts for each addition or alteration. Applying the England-adapted AWaRe index, Access antibiotics accounted for the majority (60.9%) of prescribing, followed by Watch (37.9%) and Reserve (0.8%); 0.4% of antibiotics remained unclassified. There was unexplained 2-fold variation in prescribing between hospitals within each AWaRe category, highlighting the potential for quality improvement. CONCLUSIONS:We have adapted the WHO AWaRe index to create a specific index for England. The AWaRe index provides high-level understanding of antibiotic prescribing. Subsequent to this process the England AWaRe index is now embedded into national antibiotic stewardship policy and incentivized quality improvement schemes

    Biogeochemistry of Arsenic and Antimony in the North Pacific Ocean

    Get PDF
    The biogeochemical cycles of the metalloid elements arsenic and antimony were examined along a 15,000 km surface water transect and at 9 vertical profile stations in the western North Pacific Ocean as part of the 2002 IOC Contaminant Baseline Survey. Results show that the speciation of dissolved arsenic (As III, As V, and methylated As) was subtly controlled by the arsenate (AsV)/phosphate ratio. An additional fraction of presumed organic arsenic previously reported in coastal waters was also present (~15% of the total As) in oceanic surface waters. Dissolved inorganic antimony displayed mildly scavenged behavior that was confirmed by correlations with aluminum, but atmospheric inputs that may be anthropogenic in origin also affected its concentrations. Monomethyl antimony, the predominant organic form of the element, behaved almost conservatively throughout the water column, radically changing the known biogeochemical cycle of antimony

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%